![Zibro S185 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/zibro/s185/s185_operating-manual_3782952004.webp)
A
SPECIFICATIONS
To be used as indication, subject to modifications.
*
Conform EN 14511
**
Moisture removal at 32°C, 80% RH
S95
S125
S185
S245
Cooling capacity *
kW
2.7
3.5
5.3
7.0
D
D
D
D
2.8
2.8
2.8
2.9
Heating capacity
kW
2.8
3.8
5.7
7.6
D
D
D
D
3.2
3.2
3.4
3.5
Dehumidification capacity (max) **
Ltr/day
19
24
36
48
Power consumption cooling
kW
0.88
1.17
1.9
2.6
Power consumption heating
kW
0.88
1.17
1.9
2.6
Mains
Volt/Hz/Pf
220-240/50/1
220-240/50/1
220-240/50/1
220-240/50/1
Current (nom)
A
3.6
5.1
8.7
12.8
Airflow (max)
m
3
/h
480
550
730
1000
For rooms up to
m
3
90
110
150
200
Dimensions indoor unit (WxDxH)
mm
718x180x240
770x180x240
1033x202x313
1033x202x313
Dimensions outdoor unit (WxDxH)
mm
669x296x506
769x328x552
829x328x552
929x372x652
Weight indoor unit
kg
7
7
14
14
Weight outdoor unit
kg
24
32
42
56
Refrigerant/charge
type/gr
R407C/540
R407C/900
R407C/1680
R407C/2300
Noise level indoor unit (max)
dB(A)
36
38
43
47
Noise level outdoor unit (max)
dB(A)
50
50
60
54
Operating range
ºC
10-40
10-40
10-40
10-40
Unit protection indoor
IP
IP X0
IP X0
IP X0
IP X0
Unit protection outdoor
IP
IP X4
IP X4
IP X4
IP X4
COP *
Model
EE Class
EER *
COP Class
4
4
Defective electrical devices and batteries must be kept separate from household
waste. Ensure that there is effective recycling where possible. Ask you local