Install the wick to the wick sleeve according to the allo-

wed direction engraved on the wick sleeve. 

Install  the  wick  sleeve  (with  wick)  to  the  primary  air

tube. And then turn the wick sleeve clockwise to set in

the handle arm.

Install the bracket. Then tighten the screw which is hol-

ding the stem.

Put the wick holder chassis back into position. 

Screw the four wing nuts hand tight.

Place the knurled wick adjustment knob on the wick

mechanism. Turn the knob as far to the right as possi-

ble. Press the tip-over switch. Check that the wick can

be lowered completely. Repeat this check a number of

times. If the wick cannot be lowered completely it has

not been placed correctly. If this is the case, repeat the

procedure from No. 12. Pull the knurled wick adjust-

ment knob off the heater.

Put the cabinet back into position and tighten the three

screws. Put the knurled wick adjustment knob back into

position. Now put the combustion chamber back into

position. Check that it is level by sliding it slightly to the

left and the right by its handle. Close the grill. 

Put the filled removable tank into position. Put the bat-

teries into the battery holder (ensure that the positive

and negative poles match the + and – marks indicated

on the battery housing). Wait 30 minutes after repla-

cing the tank and batteries before using the heater.

19

18

17

16

15

14

13

12

19b

17b

14b

14a

18b

18c

18a

18d

19a

16

17a

15

12b

13a

12a

13b

Содержание R18E

Страница 1: ...2 14 26 38 50 62 MANUEL D UTILISATION GEBRAUCHSANWEISUNG INSTRUCCIONES DE USO OPERATING MANUAL ISTRUZIONI D USO GEBRUIKSAANWIJZING 3 2 5 4 1 R 18 E...

Страница 2: ...3 PAGE PLIANTE 2 AUFFALTBLATT 5 HOJA DESPLEGABLE 4 FOLD OUT PAGE PIEGHEVOLE 1 UITVOUWBLAD EMC LV...

Страница 3: ......

Страница 4: ...y Please read these Directions for Use first to ensure the maximum lifetime for your Zibro heater This appliance comes with a 48 month manufacturer s warranty on all defects in material or workmanship...

Страница 5: ...coil Battery holder Air quality control system Information display E Guard Remove all packaging materials refer to Section A Fig A Fill the removable tank and wait 30 minutes before you ignite the hea...

Страница 6: ...indow or door slightly ajar 2 5 cm We also recommend doing this in highly insulated or draught free rooms and or at altitudes above 1 500 metres Do not use your heater in cellars or other underground...

Страница 7: ...cardboard Fill the removable tank as indicated in Section B Insert the batteries into their holder at the back of the heater Fig F Ensure that the positive and negative poles match the and marks indi...

Страница 8: ...ait approximately 30 minutes before you ignite the heater This allows the glass fibre wick to soak up the fuel Follow the same procedure when you have completely burnt up all fuel from the tank and af...

Страница 9: ...ilation of the room is improved e g by opening a door or window a little more to avoid that the heater shuts off When the ventilation of the room is improved the VENT lamp and buzzer will be deactivat...

Страница 10: ...er had burnt up almost all the fuel After having refilled and replaced the removable tank wait for 30 minutes before igniting the heater You are using the incorrect type of fuel Refer to THE RIGHT FUE...

Страница 11: ...k H STORAGE END OF THE HEATING SEASON We recommend that you burn up all the fuel in the fuel tank at the end of the heating season and store the heater properly Follow the procedure on the next page I...

Страница 12: ...icative K WARRANTY PROVISIONS Your heater comes with a 48 month warranty starting on the date of purchase Within this period all defects in material or workmanship will be repaired without any charge...

Страница 13: ...ys aware of the presence of a burning heater 2 Do not move the heater when it is burning or still hot Do not refill nor service the heater when it is burning or still hot 3 Position the front of the h...

Страница 14: ...slightly and then remove it from the base plate Unscrew the four wing nuts from the wick holder Lift up the wick holder and the wick mechanism Remove the screw on the stem holding the bracket and rem...

Страница 15: ...the wick cannot be lowered completely it has not been placed correctly If this is the case repeat the procedure from No 12 Pull the knurled wick adjust ment knob off the heater Put the cabinet back i...

Страница 16: ...P 7 1 3 cm 3 7...

Страница 17: ...Rev 09 10 PVG Traffic avg 090916 man_R18E Printed in Japan 7973000903...

Отзывы: