Zibro R 617 E Скачать руководство пользователя страница 3

GENERAL DIRECTIONS FOR USE

Below you will find the main steps to be taken for

using your heater. For more details, please refer to

the MANUAL (pages 53 ff.).

The first time you ignite your heater it will smell

like ’new’ for a short time.

Store your fuel in a cool and dark place.

Fuel has a limited shelf life. Start every heating

season with new fuel.

The right quality of fuel will be assured, when you

use Zibro Extra or Zibro Kristal for your heater.

If you change to another brand and/or type of

paraffin oil, you must first finish up all the

remaining fuel in the heater.

MAIN COMPONENTS

OFF Button

Knurled wick 

adjustment knob

Battery holder

Combustion 

chamber

Combustion 

chamber handle

Fuel indicator

Grill

Lid for removable

tank

Removable tank

Fuel gauge 

removable tank

Wick height lock

Spark ignition

Air quality control

system

Information display

(E-Guard)

A

B

C

4

E

F

G

H

I

J

K

L

M

N

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

Remove all packaging materials (refer to Section A, Fig. A).

Fill the removable tank 

I

and wait 30 minutes before you 

ignite the heater (refer to Section B, Fig. I).

Insert the batteries into the battery holder 

3

(refer to Section A, Fig. F).

Check whether the combustion chamber 

D

is fully upright

(refer to Section A, Fig. E).

Ignite the heater by turning the knurled wick adjustment 

knob 

B

as far to the right as possible

(refer to Section C, Fig. K).

After igniting the heater it will take 10 to 15 minutes before

you can check if the heater burns well (refer to Section D).

Switch off the heater (refer to Section E).

1

2

3

4

5

6

7

4

51

Содержание R 617 E

Страница 1: ...R 617 E 2 14 26 38 50 62 74 MANUEL D UTILISATION GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO OPERATING MANUAL ISTRUZIONI D USO GEBRUIKSAANWIJZING 3 2 6 5 4 1...

Страница 2: ...ead these Directions for Use first to ensure the maximum lifetime for your Zibro heater This appliance comes with a 24 month manufacturer s warranty on all defects in material or workmanship We wish y...

Страница 3: ...ber handle Fuel indicator Grill Lid for removable tank Removable tank Fuel gauge removable tank Wick height lock Spark ignition Air quality control system Information display E Guard A B C 4 E F G H I...

Страница 4: ...ellars or other underground areas SAFE TOP The heater is supplied with a safe top This application decreases the temperature of the top plate In this way the risk of harmful accidents at accidentally...

Страница 5: ...E Close the grill Slightly lift it to reposition it in its slot E Open the lid of the removable tank H and remove the piece of cardboard Fill the removable tank as indicated in Section B Insert the ba...

Страница 6: ...erefore provide extra ventilation or ignite the heater outs ide the living room When you use the heater for the first time first put the filled removable tank into place and then wait approximately 30...

Страница 7: ...uzzer will be heard and the VENT lamp Yellow will be lit When this signal is given ensure that the ventilation of the room is improved e g by opening a door or window a little more to avoid that the h...

Страница 8: ...e ignition Replace Fig O E You have run out of fuel from the tank or the wick has been replaced After having refilled and replaced the removable tank wait for 30 minutes before igniting the heater IRR...

Страница 9: ...wear 1 THE BATTERIES You may replace the batteries yourself Do not dispose of old batteries along with the other domestic waste Follow the locally applicable regulations regarding the disposal of dom...

Страница 10: ...s specified J TRANSPORTATION Take the following measures to avoid fuel leakage during the transportation of the heater Let the heater cool down Remove the removable tank I from the heater and remove t...

Страница 11: ...d the Directions for Use carefully first In case they offer no solution please take the heater to your dealer for repair Highly inflammable substances may induce uncontrollable burning causing flames...

Страница 12: ...the wick to loosen the three wick pins and remove the wick from the wick holder Ensure that you are wearing gloves and that you have a container in which to put the old wick Put the wick holder back i...

Страница 13: ...the wick position to 1 Put the cabinet back into position and tighten the three screws Put the knurled adjustment knob back into position Now put the combustion chamber back into position Check that i...

Страница 14: ...E E E E E E E E E E E E E E E E E E E E E E E E F R...

Страница 15: ...E E E E E E E E E E E E E E E E E E E E E E E E A B K D G E J F C L H I K M N...

Страница 16: ...zibro com SUOMI Appliance Finland Oy Piispantilankuja 6C 02240 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com F FI IN N 4 UNITED KINGDOM Scott Brothers Ltd The Old Ba...

Отзывы: