![Zibro R 56 C Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/zibro/r-56-c/r-56-c_operating-instructions-manual_3741483061.webp)
I
TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
Let the heater cool down.
Remove the removable tank
I
from the heater and remove the fuel filter
(Fig. N). Some drops may leak from the filter; keep a cloth at hand. Store the
fuel filter and the removable tank outside the heater.
Place the transportation cap into the position of the fuel filter (Fig. O).
Press it tight.
Always move the heater in an upright position.
J
SPECIFICATIONS
Ignition
electrical
Dimensions (mm)
width
428
Fuel
paraffin
(including base plate) depth
295
Capacity (kW)
*
2.4
height
513
Suitable space (m
3
)
**
40-85
Accessories:
manual fuel pump
Fuel consumption (l/hr)
*
0,25
transportation cap
Fuel consumption (g/hr)
*
200
fuel cap cover
Burning time per tank (hr)
*
16
batteries
Capacity removable tank (litres) 4.0
Required batteries
2x R20 KG,
Weight (kg)
9
size D, 1.5V
Wick type
F
*
At maximum setting
**
Specified values are indicative
K
WARRANTY PROVISIONS
Your heater comes with a 24-month warranty starting on the date of purchase.
Within this period all defects in material or workmanship will be repaired without
any charge. The following provisions shall apply regarding this warranty:
We expressly dismiss all other claims for damages, including consequential
damages.
Any repairs or replacements of components within the term of warranty will
not result in an extension of the term of warranty.
The warranty will no longer apply, when the heater has been modified,
non-original parts have been used, or when it is repaired by third parties.
3
2
1
4
3
2
1
4
58
O
transportation cap
N
fuel filter