4
75
8.
Damage caused by not using suitable Zibro filters is not covered by the gua-
rantee.
To prevent unnecessary expense, we recommend that you always first carefully
consult the instructions for use. Take the air conditioner to your dealer for repairs
if these instructions do not provide a solution.
L
TECHNICAL DATA
To be used as indication, subject to modifications
*
Conform EN 14511-2004
**
Moisture removal at 32°C, 80% RH
Environmental information: This equipment contains fluorinated greenhouse
gases covered by the Kyoto Protocol. It should only be serviced or dismantled by
professional trained personnel.
This equipment contains R410A refrigerant in the amount as stated in the table
above. Do not vent R410A into atmosphere: R410A, is a fluorinated greenhouse
gas with a Global Warming Potential (GWP) = 1975.
Waste electrical products should not be disposed with household waste. Please
recycle where facilities exist. Check with your local authority or retailer for
recycling advice.
Model
P 28
Cooling capacity*
W
2800
A
2.61
Power consumption
kW
1.07
Current nom.
A
4.5
Mains
V/Hz/PH
220 - 240 / 50 / 1
Air delivery max.
m
3
/h
300
Dehumidification max. **
L/24h
28
Room size
m
3
70 - 90
rotary
Refrigerant
type/gr
R-410A / 650
Thermostat range
°C
16 - 32
3
Noise level
dB(A)
52
Dimensions (w x h x d)
mm
435 x 785 x 390
Weight
kg
30
IP 20
yes
yes
T3.15A, 250V
EE Class*
EER*
Compressor type
Fan speeds
Fuse rating
Remote control
3M
TM
HAF filter
Unit protection
man_P28_1 22-02-2008 15:42 Pagina 75