4
53
L
TECHNICAL DATA
To be used as indication, subject to modifications
*
Cooling capacities are measured at 27°C, 60% RH
**
Moisture removal at 32°C, 80% RH
Model
P100
P120
Cooling capacity *
- enthalpy difference (nom)
Btu/hr
10000
12000
- enthalpy difference
kW
2.9
3.5
- conform EC regulation
W
2200
2500
Power consumption
W
880
960
Current nom.
A
4.0
4.2
Mains (1PH)
V/Hz
Air delivery max.
m
3
/h
Dehumidification max. **
L/24h
18
24
Room size
m
3
75
85
Compressor model
Refrigerant
gr
R407C / 470
R407C / 480
Thermostat range
°C
Fan speeds
Noise level
dB
Dimensions (b x d x h)
mm
Weight
kg
29
31
Unit protection
380 x 400 x 750
IP 20
2
52 - 58
rotary
220 - 240 / 50
18 - 32
360