background image

 

— 5 — 

position and quantity shall be determined according to requirement) so as to make air pressure 

in two casings keep balanced and ensure that materials are fed to and discharged out of the 

buckets  smoothly.  There  is  access  door  in  the  maintenance  casing  for  observation  and 

replacement of buckets and bucket belt. 

2.3.3 Elevator Foot 

It  consists  of  elevator  foot  housing,  tail  pulley,  tail  pulley  shaft,  tensioner  and  feeding 

hopper.  Elevator  foot  is  fitted  with  direct  and  converse  feeding  hoppers  which  can  meet  the 

different requirement of users. Tensioner is used to adjust the relative position of head pulley 
and tail pulley and tension the bucket belt so as to prevent the offset and slipping. Elevator feet 

are  fitted  with  discharging  flapper  at  both  sides  for  removing  the  remaining  materials  and 

impurities inside the machine. 

 

2.3.4 Buckets and Bucket Belt 

Bucket includes steel bucket and light high-strength plastic bucket. Users can make choice 

according to the property of materials. Buckets are fixed to the bucket belt with special-purpose 

bucket screws in certain spacing. 

Bucket  belt  is the strengthened fabric rubber belt with low stretching rate,  high strength, 

wear proof quality, low weight and without toxicity and smell. 

3 INSTALLATION, ADJUSTMENT AND COMMISSIONING 

3.1 Installation Conditions 

3.1.1  The  foundation  for  elevator  foot  is  poured  with  concrete  and  has  a  thickness  not 

lower than 300mm. It is required to be level and solid enough to bear the weight of the machine 

and meet the requirement of load in the running process. 

3.1.2 The foundation should have the embedded anchor bolts or steel plate with foot with 

size larger than elevator foot. 

3.1.3  When  elevator  housing  need  pass  through  the  floors,  floors  should  have  the 

reserved holes. Long hole is recommended for convenience of installation and adjustment. See 

Figure 4 and Table 3 for sizes. 

3.1.4 There should be sufficient space not smaller than 500mm between cover of elevator 

head and building (or structural member). 

3.1.5    The  access  door  of  the  housing  (central  line)  should  be  arranged  in  a  position 

about 1400mm away from the floor or ground for convenience of inspection and repair. 

3.1.6 The working bench for installing the drive should be installed on the floor (or platform 

of structural member) and fixed with anchor bolts. 

3.1.7 It should be designed that a working platform is available at the part of head pulley 

for convenience of operation and repair. 

3.2 Installation 

3.2.1 Position the elevator foot on the finished foundation, take the flange face of elevator 

foot as datum for aligning (it is allowed to insert the leveling iron pad with thickness not larger 

than 40mm) with deviation not higher than 1/1000, and fix the anchor bolts. 

3.2.2  Mount  the  housings  section  by  section  from  bottom  to  top  according  to  the 

requirement of technological design, and use seal for sealing. 

Содержание TDTG36/18

Страница 1: ...1 BUCKET ELEVATOR OPERATION MANUAL JIANHSU ZHONGTIAN AGRO MACHINERY CO LTD...

Страница 2: ...ull understanding of the ministries and its structure and function then have operation and maintenance of the machine Due to the continuous improvement of product structure after a certain time period...

Страница 3: ...ble wear proof plate 1 1 6 Explosion proof elevator housing is available and can effectively prevent the explosion of dust 1 1 7 Tensioner is fitted with spring buffer device so as to reduce the vibra...

Страница 4: ...310 3 115 376 10 9 TDTG40 28255 354 2 147 360 3 132 426 9 9 280 319 2 159 360 3 132 426 10 9 TDTG50 18380 545 3 135 250 2 143 316 9 9 300 339 2 174 250 2 143 316 8 9 TDTG50 23380 545 3 135 310 3 115...

Страница 5: ...elevator foot is poured with concrete and has a thickness not lower than 300mm It is required to be level and solid enough to bear the weight of the machine and meet the requirement of load in the run...

Страница 6: ...he inspecting and repairing motor after mounting the drive and connecting the power they can start the inspecting and repairing motor by touch to drive the belt and then mount buckets one by one 3 2 6...

Страница 7: ...her side by using the same method During the adjustment the height of bearings at two sides should be same 3 3 1 3 After tensionness is adjusted the fixing nuts must be fastened so as to prevent eleva...

Страница 8: ...be made at the bottom of bucket so as to reduce the negative pressure and make the feeding and discharging of powder materials smooth 3 5 3 The hopper should receive the materials smoothly and feeding...

Страница 9: ...site to the starting sequence 5 TROUBLES AND TROUBLESHOOTING Table 6 Trouble and Troubleshooting Trouble Cause Troubleshooting Method Materials return 1 Follow up equipments are in trouble 2 Feeding a...

Страница 10: ...of bearing Driving parts should be firstly removed from the driving end then bearing can be removed and replaced 6 5 Maintenance of motor gearbox hydraulic coupling should follow their operation manu...

Страница 11: ...N518 F90511 18 14 200 5 TDTG50 23 SN518 F90511 23 16 250 6 TDTG50 28 SN518 F90511 28 16 300 9 CAUTIONS 9 1 During the operation of equipment any parts of human body must not touch the rotating parts o...

Страница 12: ...ANGSU ZHONGTIAN AGRO MACHINERY CO LTD ADD No 7 ZhongDaLi Road New industrial Park DaiBu Town LiYang JiangSu China P C 213300 Tel 13814760009 Fax 0086 519 87256670 Http www jsztmt com E mail info jsztm...

Отзывы: