![Zhone IMACS 8000 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/zhone/imacs-8000/imacs-8000_user-manual_3745919070.webp)
4-6
Reference Guide
Model No.
Running Head
Voice Modules
Applications
4.2.5
TR008 Application
BellCore’s TR-TSY-000008 standard describes the requirements necessary for a Local Digital
Switch (LDS) to connect to a remote terminal (RT) across a T1 (1.544Mbps) digital interface.
The standard allows supporting from one to four T1s per RT without facility Automatic
Protection Switching (APS), and three to five T1s with facility APS.
The LDS can interface the RT in Mode I (no concentration), Mode II (2:1 concentration), and
Mode III (24 special-service circuits on 24 DS1 time-slots). TR008 supports traditional POTS,
CLASS, and Coin services but does not support ISDN BRI.
If the service provider deploys a channel bank at the customer premise that does not provide
TR008 capability then it needs a 1/0 DCS with TR008 capability at the central office to
integrate with the LDS.
In addition to the many Integrated Access System functionality’s, the system also supports
TR008 switch integration. The Integrated Access System with TR008 operation can connect
directly to the LDS, eliminating the need for the 1/0 DCS as shown in Figure 4-2.
Figure 4-2.IAD using TR008
The TR008 feature can support 48 lines on 2 T1 links. This is an ideal vehicle to provide
integrated POTS services for line sizes of 48 and under. This system supports Mode I, Shelf
A&B of TR008 specification. The system supports extensive testing and diagnostics
capabilities which minimizes troubleshooting and allow high service levels.
CAUTION:
For c
ontin
ued
protection a
gainst fire
,
replace onl
y with t
he same
type and r
ating of fuse
Premisys
Comm
unications
, Inc.
Model IMA
CS/600
T 5A
250
V
IEC
Fuse
5A
SB
250V
UL/
CSA
24/48V
5A
LISTE
D 9
K09
LR
770
63
120-
200-240V
~
3A, 50 / 60 Hz
Tele
phone
Equ
ipment
Class 2 P
owe
r Source
®
®
UL
+ -
+ -
+ -
R
G
R
C
O
M
VN
VB
VA
HSU
-T
530/3
5
S
60
HSU-
T
530
/35
S
60
HSU-T
530/
35
S
60
HSU
-T
530/
35
S
60
HSU
-T
530
/35
S
60
HSU
-T
530
/35
S
60
BRI
HSU
530/
35
S
60
P
2
P
1
P
4
P
3
FXO
8139
N
O
D
E
T
E
R
M
C
O
M
P
P
1
P
1
CPU
CLO
CK
NVRA
M
W1
-1
CSU
W1-2
DSX
WA
N
IF
T1+
DS1
2 x T1/E1
IAD
Local Digital
Switch
POTS/Class
48 TR008 Lines
MODE 1 (Shelves A&B)
Customer Premise
Central Office
D
S
X
P
a
n
e
l
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...