Data Cards
17-7
OCU-DP Card
OCU-DP Card User Screens and Settings
ERR COR
The Error Correction setting is used only on the OCU-DP 2 Card. It provides different
methods of error correction, depending on the data Rate selected. The default ERR COR
setting is off. If you choose subrate speeds of 9.6k or less in the Rate setting, the Error
Correction option maj-v (majority voting) is available. Using majority-vote error correction
allows the system to poll the data for errors and decide on the correct data based on the
repeated bit pattern.
The bch error correction option is available for 19.2K only. Bch Error Correction is not
supported on the OCU-DP5 or OCU-DP 10 Card. Maj-v is supported for 2.4, 4.8, and 9.6K.
SECOND
Secondary channel operation allows the DSU/CSU to establish a separate lower-speed data
circuit with the OCU-DP port. When synchronized, this special circuit can be used for testing
and maintenance of the main circuit, or for transmission of other low-speed data. The settings
are on and off.
The secondary channel is transported in the 8th bit position of the DS0 time slot to which the
OCU-DP is assigned. Table 17-3 shows the secondary channel rate associated with the various
primary port rates supported by the card. For a further description of the secondary channel
function, refer to Pub 62310 and TA-TSY 000077 and TA-TSY 000083.
Table 17-3. OCU-DP Primary and Secondary Channel Rates
USER LB
The User Loopback (USER LB) is a specialized code conversion function that is only relevant
in Taiwan and some other countries in the Far East. The options are d and o, neither of which
has any effect in North America.
Primary Port Rate
Secondary Channel Rate
56 kbps
2666 bps
19.2 kbps
1,066 bps
9.6 kbps
533 bps
4.8 kbps
266 bps
2.4 kbps
133 bps
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Страница 659: ...Reference Guide A 15 A 4 2 External Talk Battery Fuses Manufacturer Part NumberA3 Little Fuse 218 005 Bussman GDC 5...
Страница 674: ...A 30 Reference Guide Model No Running Head...
Страница 729: ...Pin Outs C 31 C 8 HSU Cards...
Страница 752: ...C 54 Pin Outs Model No Running Head...