Data Cards
16-5
LDSRU-10P Card
LD-SRU Card User Screens and Settings
Table 16-1. Main Screen Actions
Table 16-2 lists the SRU Card Main Screen parameters and available option settings.
Table 16-2. Main Screen Option Settings and Defaults
Notes:
1. Time slot 16 is not available if the port is assigned to an E1 WAN link whose TS 16 is
programmed for cas or ccs.
2. Although offered as frame options, b-10, b-20 and x.50 are not supported. Additionally.
b-5 circuits must be confined onto two groups: 1 through 5 and 6 through 10.
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Updates certain time-related information fields that are not automatically
updated (i.e., test status).
Copy
Copies the contents of the current column to the next column. Useful if you
change a lot of entries in one column and want to repeat those changes in
subsequent columns.
Test
Initiates and monitors testing of all SRU card ports. Refer to the Test section
of this chapter.
Main
Returns to the System Main Screen. If changes are made to settings and not
saved, you will be prompted to save or lose changes.
Parameter
User Options
Notes
Default
STATE
stdby act
stdby
WAN/SRV
none wan (w1-1 through w4-2) serv (P1 through P3)
w1-1
TS
01-24 01-31
1
01
FRAME
a b-5 b-10 b-20 x.50 adpcm hlink nlink
2
a
RATE
.3 1.2 2.4 4.8 9.6 14.4 19.2 28.8 38.4
3
.3
SR TS
n/a 1 1-5 1-10 1-20
1
INTF
asyn sync v.14
asyn
8 7 6 5
8
COM CF
1 2
4
1
none odd even space mark
none
CTS
perm l0 l30 l60 l100 rl0 rl3 rl6 rl10 off
perm
TX CLK
n/a int ext
n/a
LB
off dte net
off
LB GEN
n/a off ocu csu dsu
off
LB DET
n/a w/to on off
off
DL OPT
off on
5
n/a
ADPCM
n/a P1 P2 P3
n/a
MAJ ERR
off on none 10e-3 10e-4 10e-5 10e-6 10e-7 6
off
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Страница 659: ...Reference Guide A 15 A 4 2 External Talk Battery Fuses Manufacturer Part NumberA3 Little Fuse 218 005 Bussman GDC 5...
Страница 674: ...A 30 Reference Guide Model No Running Head...
Страница 729: ...Pin Outs C 31 C 8 HSU Cards...
Страница 752: ...C 54 Pin Outs Model No Running Head...