Reference Guide
5-29
System Configuration and Operation
Alarms
5.7.6
Alarm Handling
The report alarm function attempts to send alarm information to a remote printer, network
management system (NMS), or other device, in addition to recording the alarm in the Alarm
History log. These features use the built-in serial port and modem on the Interface card. You
will need to change the settings in the Ports screen on the Interface card to be either modem
or printer, and the printer (Prt) screen on the CPU card to activate the alarm reporting functions
to a printer or modem interface.
Alarms set to either log or report record occurrences automatically to the Alarm History
Screen. To view that screen, press “h” (History command) in the Alarm Screen. Figure 5-18
shows a typical Alarm History Screen, in which you can update the log with any new alarms
that occur. To do this, press “r” to select Refresh in the Alarm History Screen. Or, to delete
all entries in the log, press “c” to select Clear in the Alarm History Screen.
The alarm log may contain more than one screen (page) of data. To scroll through the log,
press “u” or “d” (pgUp or pgDn) to move up one page or down one page at a time. The latest
alarms appear at the beginning of the log, which is on the first page of the alarm log.All alarms
(except those set to ignore) appear in the Alarms field in the upper right corner of the screen,
regardless of their setting in the Alarm Filters screen. The display in the Alarms field is an
abbreviated version of the alarm name and slot number.
Figure 5-18.Typical Alarm History Screen
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Страница 659: ...Reference Guide A 15 A 4 2 External Talk Battery Fuses Manufacturer Part NumberA3 Little Fuse 218 005 Bussman GDC 5...
Страница 674: ...A 30 Reference Guide Model No Running Head...
Страница 729: ...Pin Outs C 31 C 8 HSU Cards...
Страница 752: ...C 54 Pin Outs Model No Running Head...