7
Installation
7.1
Preparatory activities
The sensor may only be installed by trained qualified staff and in accordance with the provisions and
specifications provided by the vehicle manufacturer or operator.
Installation location
When installing the sensor, make sure that the installation location is protected from damage such as
stone chipping or other mechanical impacts. Avoid surrounding the sensor with metal in the form of a
Faraday cage as this may impair the function of the sensor.
The installation position of the sensor can be selected freely.
Damping
The sensor must be installed on the component that is to be monitored. Keep the mechanical damping
effect between the component to be monitored and the sensor as low as possible.
Do not install any rubber elements or similar between the component and the sensor.
Fastening
Brackets or parts to which the sensor is fastened must not show any resonance vibrations in the relevant
frequency range (e.g. no protruding brackets).
Fire protection
Observe the fire protection requirements as defined in DIN EN 45545-2. When selecting the installation
location, make sure that you install the sensor at a distance from other components that are not in
conformity with table 2 of the DIN EN 45545-2 standard.
• Horizontal minimum distance: 20 mm
• Vertical minimum distance: 200 mm
7.2
Installing the sensor
Install the sensor with four M6x45 hexagon screws (material number: 0636.104.852).
Requirements:
•
Make sure that the screw-in depth is at least 15 mm.
•
Only use the hexagon screws supplied with the sensor once.