6057 758 101 - 2005-02
6
1
Technical data
1.1
Technical data, installation dimensions
Nominal direct voltage for ZF
hysteresis clutches and brakes at
nominal torque and a coil
temperature of 120 °C:
30 V DC
Permissible residual ripple:
1.5 V
Operating voltage range:
24 V to 36 V DC
Open circuit power consumption:
< 150 mA
Maximum current input:
2.8 A
(depending on unit size)
Fuse:
fine-wire fuse 4A
medium time-lag fuse
Voltage output:
10 V = + /
–
0.8 V
20 mA
(R
a min
= 500
Ω
)
Frequency input:
input resistance
R
E
≥
3.3 k
Ω
Switching threshold “low” to “high” > 11.5 V DC
Switching threshold “high” to “low” < 4.0 V DC
Ambient temperature:
0 to + 50 °C
Storage temperature:
-30 to + 70 °C
Humidity class:
DIN IEC 68, part 2-30
Safety class according
to DIN 40 050:
IP 30
Rack:
19” 7 TE plug-in module
Connection:
1
8-pin pull-off screw-type
terminal (within the scope
of supply)
Weight:
0.6 kg
NOTE
The screw-type terminal block is not suitable for bus
assembly. Make sure that connecting cables are long
enough or that the screw-type terminal block on the
rear of the assembly rack is accessible.
Technical Data
Electronic control unit ERM