ZERO EMISSION VEHICLES AUSTRALIA

8-16 CELL LITHIUM BATTERY MANAGEMENT SYSTEM

BMS min temp

-41C to 100C The  minimum  allowable  temperature  for 

the  battery  pack.  If  a  temperature  below 
this  threshold  is  detected,  a  warning  will  be 
generated and charging will be disabled.

Set to -41C to disable (will show as “Off”)

BMS max temp

0-101C

The  maximum  allowable  temperature  for 

the  battery  pack.  If  a  temperature  above 
this  threshold  is  detected,  a  warning  will  be 
generated and chargers and loads will both be 
disabled.

Set to 101C to disable (will show as “Off”)

Charger voltage

0-70V

For CAN integration with TC Chargers only.

The maximum voltage that the BMS will instruct 

the charger to reach.

Charger current

0-100A

For CAN integration with TC Chargers only.

The maximum current that the BMS will instruct 

the charger to reach.

Stationary mode

No/Yes

Whether the BMS behaviour should be set for 
stationary  applications.  Please  see  “Stationary 

Mode” section for further explanation.

Reverse current display

No/Yes

By default, the BMS16 displays discharge amps 

as positive / charge amps negative. If preferred, 

you  can  reverse  the  display  so  that  discharge 

amps are negative / charge amps are positive.

Night Brightness

0-100%

Adjusts  the  brightness  of  the  LCD  display  in 
low  light  mode,  to  reduce  screen  glare  at 
night. Toggle between full brightness and night 

brightness by swiping a finger up/down.

Buzzer On

Yes/No

Selects whether the Monitor should sound the 
buzzer for alerts. (Safest to leave this on.)

Use Fahrenheit

Yes/No

Changes  display  of  temperature  units  to 
Fahrenheit instead of Celcius.

SoC Display

Percent or 

Amp-Hours

The battery State of Charge value displayed on 
the Monitor can either be shown as a percentage 
of full charge, or as the number of amp-hours 
remaining.

Stationary Mode

The BMS16 has two main modes of operation, either normal (for mobile / EV applications) 
or Stationary Mode (for off grid / backup battery type applications). In normal mode, if an 

under- or over-voltage is detected, the LV or HV output relay will be disabled respectively, 
and will remain off until the device is either power cycled or (more commonly) they are re-
enabled whenever the device wakes from sleep.

In Stationary mode, the outputs will automatically reset if the voltage recovers sufficiently. 

The BMS Hysteresis setting is used to adjust the amount that the voltage needs to recover. 

For  example,  a  hysteresis  setting  of  0.1V  will  cause  the  HV  output  to  disable  once  the 
voltage exceeds 0.1V above the programmed Max Voltage threshold, and the output will 
automatically re-enable once the voltage has dropped under 0.1V below the Max Voltage 

threshold.

BMS Power Consumption Protection

An inherent problem with any BMS which powers itself from the cells it is monitoring is that 

the BMS itself can slowly discharge the cells, which can eventually flatten cells – particularly 
if powering contactors or monitors, and no charging source is present for an extended period. 

To prevent possible damage, the BMS16 is able to switch of its own power supply if any cells 
get critically low (under 2.0V). If your BMS has turned off due to a critically low cell, simply 
attach a charging source to the batteries then press the power button to re-enable the BMS.

Tech Support and Warranty Information

All  ZEVA  products  are  covered  by  a  12  month  warranty  against  manufacturing  faults  or 
failures  under  normal  operating  conditions. The  warranty  does  not  cover  misuse  of  the 

product, including but not limited to: excessive voltage or reversed polarity on terminals, 
short circuits on outputs, opening of housings and/or modification of internal electronics, 

severe impact damage, submersion in water.

We have taken great care to design a safe and reliable product, but faults can happen. If 
you believe your product has a fault, please contact us via our website to discuss. If it is 
determined that a hardware fault is the likely cause, we will provide an RMA number and 
return address to proceed with repairs.

If you have any questions not covered by this manual, please contact us via our website:

http://www.zeva.com.au

9