background image

10

 

2 x Electrolyte Solution (Electroliquid Solution - ES)

 

1 x Electrode Cable

 

1 x User Manual

 

1 x Warranty

 

1 x Electro Dish Fastener (Dish Fastener - DF)*

 

APPLICATION INSTRUCTION 

a.  ZEUS ZPS19 DEVICE INSTRUCTION MANUAL 

  Connect the device to 

a wall socket with the 

“adapter input socket” 

(adapter input) using the 

provided adapter, and con-

nect the electrode cable to 

the electrode input. After 

the connections are made, 

the device can be operat-

ed with the ON / OFF but-

ton. (Figure 1).

 

When the device is turned on by the ON / OFF button, first the opening 

screen will appear (Figure 2), then the application screen with three touch 

buttons will be displayed where the application mode can be selected 

(Figure 3). On the screen there are “DC Mode” button that gives direct cur-

rent and “AC Mode” that gives alternative current, as well as “Settings” 

button used to adjust the current time. When the preferred current type 

is selected, the third screen will appear with “Load” and “Apply” and “Back” 

buttons (Figure 4). To apply the selected current, it is sufficient to follow 

the “Instruction” menu at the bottom of the screen. When the “Load” but-

ton is pressed, the device will be ready to give current and when the “Ap-

ply” button is pressed, the device will provide impulses to the electrodes 

on the electro dish. Before the impulse is given, the electrode preparation 

must be completed and the cells must be placed in the relevant section 

(see ZEUS ELECTRO DISH / ZEUS ELECTROLIQUID PREPARATION). The 

factory default setup settings of the device are set to 70 µs for the option 

of DC Mode and 5 seconds for the AC / DC Mode option. When required, 

the time can be set differently via “Settings” button (Figure 5).

1

3

5

6

7

8

9

4

2

 

DEVICE NAME & DESCRIPTION

 

Device Name 

:  ZEUS Pulse Stimulator

 

Device Description 

:  Manufacturer of cell specific constant direct

 

   

  current (DC) and alternating current (AC).

 

a.  Authorized Company :  ZEUS Bioscience Biyomedikal A.Ş.

 

b.  Producing Company  :  GenSa Genel Sağlık Hizmetleri A.Ş.

 

c.  Brand – Model 

:  ZEUS Pulse Stimulator - ZPS 19

    

 

GENERAL WARNINGS

 

Read the User Manual carefully before using the device and take into con-

sideration the indicated warnings.

 

This manual has been prepared for the safe, correct and productive use of 

the device you have received. The information and explanations that you 

will need to use the device are included in the manual. For the issues that 

cannot be solved you can contact the authorized company.

 

Do not place or use your device on wet / damp surfaces. Use a grounded 

outlet when using.   

 

INTRODUCTION & GENERAL INFORMATION

a.  INTENDED USE & PRINCIPLES OF OPERATION

 

ZEUS Pulse Stimulator provides electroporation and 

fusion of the cell with suitable electrical    current. The 

device can offer alternating current (AC) and direct current (DC).

b.  TECHNICAL SPECIFICATIONS

 

The device is controlled by touch-screen and designed to prevent the er-

rors that may arise from the user or the network by generating fixed and 

standard stimulus at one time with the command, first storing the current 

so that it is not affected by the city network and voltage fluctuations. ZEUS 

Pulse Stimulator is designed for cell suspension and in vitro applications. 

The device produces stable, standard and safe pulses at the cellular level 

only with its specific apparatus (3-c.). Technical data of the device is as fol-

lows:

 

Voltage 

:  12 V

 

Stimulus Duration  :

 

AC  

:  Adjustable

 

DC  

:  Adjustable

 

Device Dimensions  :  142x245x190 mm

 

Weight 

:  2.362 g

 

Control Panel 

:  4.3 inch touchscreen

c.  COMPONENTS & UNITS

 

ON / OFF (Power) button, digital touch screen, electrical input, electrode 

outputs are located on the device. Power cable, electrode cable and tips, 

disposable sterile dish (electro dish), dish fastener, sterile non-toxic electro-

lyte (electroliquid), main body, user manual, warranty certificate are includ-

ed with the device package. 

 

INSTALLATION & USAGE

 

The device will be delivered to the user in a shielded original box. The device 

and the accompanying apparatus should be compared with the list of box 

contents in the user manual to check for any missing parts. The user man-

ual must be read carefully before installing and using the device. Device 

installation and start-up is done by the user. The device must be placed on a 

suitable worktop and never on wet or damp surfaces. The device should be 

connected to a grounded outlet. The device is ready for usage after turning 

ON / OFF button. The type of current (AC / DC) is selected from the options 

on the touch screen and by following the commands on the screen the im-

pulse is given to the cell which was previously prepared between the elec-

trodes in the petri dish.The related details are provided in the section “10. 

APPLICATION INSTRUCTION”.  Direct technical assistance (English / Turkish 

/ Russian) can be provided during installation if necessary. 

 

SHIPPING

 

The device is shipped within 2 days after payment. Shipping costs are 

paid by the user. Transport of the device will be done through licensed and 

accredited cargo companies. Regarding the issues that may occur during 

transportation the warranty and operation protocols of the transportation 

company shall be valid. Upon the request the device can be collected di-

rectly by the receiver. 

 

FAULT FINDING & REMOVAL

 

Authorization of sale of ZEUS Pulse Stimulator device is given by the let-

ter of 89252994-401.01.05 dated 17/09/2019 of Directorate General of 

Consumer Protection and Market Surveillance of the Ministry of Trade. The 

warranty certificate has been prepared in accordance with the “After Sales 

Services” regulation prepared by the Ministry of Trade based on Article 58 

of the Law No. 6502 on Consumer Protection and published in the Official 

Gazette No. 29029 dated 13.06.2014. In case of malfunction of the device, 

please contact the vendor. In the event of warranty coverage, the existing 

defective device shall be replaced by a new device. The delivery of the new 

device shall be carried out within 1 month following the delivery of the de-

fective device to the authorized company.

 

SECURITY RECOMMENDATIONS 

  

 

The user manual should be read carefully before using the device.

 

The device should not be stored and used on wet and damp surfaces. 

 

The device should be stored and used on a suitable table or 

worktop. 

 

Since the device has an electrically operated system, it 

should be used only by authorized persons with the nec-

essary general safety precautions.  

 

WARRANTY

 

The device is not covered by the warranty in case it was misused or used 

for other purposes. The user must check that all apparatus and parts are 

complete before installation. The user accepts that the manufacturer is not 

responsible for any damages, accidents, etc. that may occur during the in-

stallation and usage of the device. The buyer accepts these warranty terms 

when purchasing the product. Details of the warranty conditions are stated 

in the warranty certificate which is delivered to the buyer after the device is 

approved by the seller.   

 

DEVICE CONTENT

 

1 x Pulse Stimulator - Main Body

 

1 x Adaptor

 

2 x Disposable Sterile Dish (Electro Dish - ED)

Figure 2

Figure 3

Figure 4

Figure 5

* Dish Fastener (DF) is optional.

Отзывы: