Air cleaner
Cab filtration
Hitches
After wirk with front implements and in case of cooler clogging
Cleaner maintenance must be done after signalization of
indicator contamination.
Indicator is accessible after opening front tractor bonnet. It
is placed close to the bend of sucking pipeline.
Contamination is mechanically signalized by a red field
which is shown after filter insertion clogging directly on
contamination indicator.
G710b
Check and if necessary clean the cab ventilation air filters
installed in the front overhang of the roof.
The filter exchange interval depends on the dustiness of
the working environment.
Partial regeneration can be performed by beating out or
blowing with compressed air.
Do the cleaning or replacement of the filter elements after
removing the covering grills in the roof overhang.
At the customer's request we supply filters with active
carbon.
Don't clean the filter; don't flush it with
compressed air.
F_02_9
Check the condition of the hitching and attachment
systems of the tractor and trailer.
F18
After work with front implements:
- Check the connections of the external hydraulic circuit of
the control of the front three-point hitch for leaks
Clogging of the coolers:
- Release and slide the cooler to the left side of the tractor.
- Clean the front walls of the engine (gearbox, air-
conditioning condenser) cooler with compressed air (blow
air in the direction from the engine).
- Remove residual dirt from the space under the hood so
that it should not be suctioned again.
C113
PREVENTIVE DAILY SERVICE
23
Содержание Proxima GP 80
Страница 1: ...Tractor is Zetor Since 1946 PROXIMA GP 80 OPERATOR S MANUAL 07 2017 90...
Страница 3: ...2...
Страница 21: ...NOTES 20...
Страница 40: ...NOTES 39...
Страница 51: ...NOTES 50...
Страница 67: ...NOTES 66...
Страница 71: ...NOTES 70...
Страница 77: ...NOTES 76...
Страница 101: ...NOTES 100...
Страница 113: ...NOTES 112...
Страница 117: ...NOTES 116...
Страница 171: ...NOTES 170...
Страница 176: ...Made in EU www zetor com zetor zetor com...