background image

Zesto Audio 2015   10 | 

P a g e

 

 

Safety Tips 
Fuses:

 

  There are many safety features built into a Zesto power amp. The purpose of a fuse is to protect the amplifier, 

sometimes they wear out and sometimes the fuse will blow. The mains fuse is the most likely fuse to blow .It is 

located in the IEC power inlet connector. All fuse types are not created equal. For example, a Slow Blow fuse is 

not the same as a Standard fuse.  

 

Warning!

 The BIA is designed for “Slow Blow” fuses. If you install a standard fuse, it is likely to blow when you 

turn the amp on. 

  For 120 Volt mains we use a 6.3 Amp Slow blow fuse. (Not a 5 Amp Slow Blow) 

  For 220, 230, 240 Volt mains we use a 3.15 Amp Slow blow fuse. 

  Generally if a fuse blows you need to replace it with the same fuse. If it blows again contact your dealer 

More Safety 

 

Caution: 

Tube electronics should not be turned ON, then OFF, then ON again quickly. This could blow a fuse. 

Once the unit is ON, it is safe to wait a minute (60 seconds) before switching OFF, then another 60 seconds 

before you can turn it back on. If you blow a fuse replace with the same slow blow fuse and don’t do that again. 

  Power amps output tubes (KT88) get very hot when operating properly; tubes can exceed 300 degrees 

Fahrenheit. 

 

Never

 move an amplifier with hot tubes. Tubes are the most vulnerable when they are hot and it will break the 

filament not the glass. 

  It’s important to provide adequate ventilation of at least 12” above the unit and on all sides. 

  To protect your speakers, turn the power amp OFF when changing any cables in your system. 

  If you break a tube, turn unit off immediately. Wait at least 1 hour for the high voltage to discharge completely to 

replace it. 

  If you spill any liquids on the unit, turn off immediately and call the factory. 

 
Grounding

 

Grounding switches apply to the XLR Balanced inputs only. 

The grounding switches do not affect the RCA SE inputs. 

If you have XLR inputs, start with both ground switches up. 

The ground switches work independently. You can adjust them for the least amount of noise. 

Example;

  

  Right channel up, left channel down  

  Right channel down, left channel up 

  Right channel up, left channel up 

  Right channel down, left channel down 

 
Tube Rolling 
Important! The wrong type of the tubes can cause considerable damage

.  

Your unit is designed to work safely with any KT88. It will also work with KT120’s, but with auto bias it will not provide 

more power, just sound different. Class A design provides plenty of power. 

Warning! 6550 

tubes will 

NOT 

work in this unit. Because they have a lower power rating, 

6550’s 

will cause 

DAMAGE

 to 

the power amp and the tubes.

 

Any damage caused by tube rolling is not covered by the manufacturer’s warranty

.

 

Содержание BIA 120

Страница 1: ...r Amplifier Owner s Manual Please read carefully before installing and operating this equipment Zesto Audio 3138 Calle Estepa Thousand Oaks California 91360 805 807 1840 www zestoaudio com george zest...

Страница 2: ...listening experience for you I am proud to put my name on it and honored to share this with you Wishing you many happy years of listening Sincerely George Counnas President of Zesto Audio FYI Zesto i...

Страница 3: ...place the unit on an unstable cart stand tripod bracket or table The unit may fall causing injury to a person or damage to the unit Mount the unit according to the manufacturer s instructions with th...

Страница 4: ...power lines or circuits contact with them could be fatal 14 OVERLOADING Do not overload wall outlets extension cords or integral convenience receptacles as this increases the risk of fire or electric...

Страница 5: ...adiate radio frequency energy and if not installed and used in accordance with the instructions it may cause harmful interference to radio communications However there is no guarantee that interferenc...

Страница 6: ...low fuse Fuse installed in mains inlet connector Optional factory installed 220V 230V 240V mains with 3 15 Amp slow blow fuse Inputs Left and Right RCA Single Ended SE High quality recessed gold pin c...

Страница 7: ...as No negative feedback Frequency response 20Hz to 50Khz 1dB Total Harmonic Distortion 0 22 at 1W into 8 Ohms Gain of 23dB Noise level 0 2 mV RMS into 8 Ohms with input shorted 1 metal film resisters...

Страница 8: ...powering up however for best performance allow at least 30 minutes of warm up It is not recommended to drive the Bia 120 directly from a DAC or to use a passive volume control The Bia is designed to b...

Страница 9: ...ully plug in the AC power cable to the power amp first then into the wall outlet Turn it on Turn on the power amp using the ON OFF switch located on the front right logo plate The amber LED indicates...

Страница 10: ...an amplifier with hot tubes Tubes are the most vulnerable when they are hot and it will break the filament not the glass It s important to provide adequate ventilation of at least 12 above the unit an...

Страница 11: ...uipment attached to this unit To return the product it must be packed in its original packaging and returned to Zesto Audio or its authorized representative via insured freight at the owner s expense...

Отзывы: