background image

DMX

USITT DMX512/1990
Ground referenced receiver
Internal switchable termination 

Mechanical

Chilli Pro 12

Height: 1000mm
Width: 400mm
Depth: 155mm
Weight: 24kg (max)
IP Rating: IP2X (indoor use only)

Chilli Pro 24

Height: 1000mm
Width: 632mm
Depth: 155mm
Weight: 50kg (max)
IP Rating: IP2X (indoor use only)

Environmental

Operating Temperature Range: +5°C to +40°C
Operating Relative Humidity: 5% to 95% Non-condensing

Always observe the operating environment information. If this environment is exceeded, it is likely that damage
will occur to Chilli Pro.

Zero 88 - Chilli Pro - Page 58 of 60

Printed: 23/03/2021 09:13:40 ES

Содержание Chilli Pro 12

Страница 1: ...es Record Memory Play Memory Clear Memories Edit Memory Sequences Program Sequence Playback Sequence Sequence Options Clear Sequence Preheat Dimmer Laws Topset Reset Dimmer DMX Controls Set Start Addr...

Страница 2: ...tion relay channels bypass switches and RCBOs contained in a slim line wall mounting enclosure The user interface and backlit LCD screen on each dimmer ensure simple convenient set up for DMX patching...

Страница 3: ...can be found at zero88 com support Once again thank you for choosing Zero 88 This manual This online manual describes the operation of Chilli Pro installation power switching and dimming units https y...

Страница 4: ...LCD screen are shown in italics for example Manual Control Set Chan Level References to the screens shown on the LCD are displayed as follows DMX 1 Temp OK Revisions Jan 2021 Manual created ES Chilli...

Страница 5: ...K2 versions Both have a single metal door on the right hand side that covers the breakers It is only the configuration of the breakers that tells them apart The MK1 has a single stack of 24 breakers w...

Страница 6: ...ision of an appropriately qualified or trained person Airflow should not be impeded by covering the ventilation openings with items such as curtains costumes cabling etc No naked flame sources such as...

Страница 7: ...round the units is 100mm each side of the unit and 50mm above and below the unit if trunking with a depth greater than 50mm is used The dimmer is provided with four 6mm diameter fixing holes for wall...

Страница 8: ...m 1 x 32 0mm Bottom 2 x 25 5mm The Chilli Pro 24 has the following knockouts Top 4 x 50 0mm 2 x 32 0mm Bottom 2 x 25 5mm Appropriate cable glands should be fitted to the knockout holes provided to pro...

Страница 9: ...tput circuit A shared Earth bus bar is mounted on the chassis of the dimmer Chilli Pro 24 The Chilli Pro 24 has the following knockouts Top 4 x 50 0mm 2 x 32 0mm Bottom 2 x 25 5mm Appropriate cable gl...

Страница 10: ...are labelled 0V and AL Any connection to the Alarm Input must be volt free and have a cable length of less than 50 metres Cabling for this input should be segregated from power wiring The connector is...

Страница 11: ...order ChilliNet Terminals Inside the dimmer the terminals for network connections use two part connectors Pull the connector from the PCB connect the wires from the CAT 5 cable and push the connector...

Страница 12: ...s which can be adjusted using the user interface buttons with settings and information displayed on the LCD If ChilliNet is enabled the LCD will be in ChilliNet mode and will display different informa...

Страница 13: ...Up and Right keys are functionally identical The Down and Left keys are functionally identical Enter Key The Enter key ENT is used to confirm numeric data entry move down menu structures confirm oper...

Страница 14: ...ttom row DMX 1 Temp OK ChilliNet Mode In ChilliNet mode the LCD will show the DMX field on the top row and the ChilliNet field on the bottom row DMX 1 Chilli Net 12 Alarm State If the alarm state is a...

Страница 15: ...ield in the default screen will show the status of the DMX input signal Receiving valid DMX dimmer data DMX xxx DMX start address or DMX Patched Receiving invalid DMX data NOT DIMMER DMX errors are oc...

Страница 16: ...mode the second line of the screen shows Chilli Net xx where xx is the dimmer number If the dimmer is in dumb mode as a result of conflicting dimmer numbers on the network the screen shows Chilli Net...

Страница 17: ...ns and press the ENT key to enter the Manual Control menu The following options are available Set Chan Level Set All Chans Use the cursor keys to scroll between the options Press the ENT key to enter...

Страница 18: ...ed as a quick method of setting the manual control levels to full or off The first push will take it 100 the second push will take it 0 etc Set All Channels Standard Mode In Standard mode you can set...

Страница 19: ...ack edited and cleared on an area basis Select the Memories option from the top level options menu and press the ENT key to enter the Memories menu Click the available options to find out more Record...

Страница 20: ...g memories allows you to store the current output levels in one of the 12 memories in the dimmer Only the levels of the dimmer channels assigned to the specified area are recorded into the memory The...

Страница 21: ...numeric keypad or cursor keys to select a memory to be output 0 12 Press the ENT key to confirm the memory number selection The dimmer performs the following Memory Zero The outputs fade to zero in 3...

Страница 22: ...or sequence being output for the selected area Programmed Memory The outputs fade to those in the selected memory in the memories fade time and replace any previous memory or sequence being output fo...

Страница 23: ...lected area and any programmed sequences for the selected area on the dimmer The screen returns to the Memories screen Edit Memory Standard Mode This option allows you to edit the channel values and f...

Страница 24: ...lliNet Mode This option allows you to edit the channel values and fade time of a programmed memory for a selected area stored on the dimmer Select the Edit Memory option from the Memories menu and pre...

Страница 25: ...memory is removed from the outputs Sequences The Chilli Dimmer can be programmed with up to 3 different sequences each containing a maximum of 12 steps In Standard mode each step in a sequence is a r...

Страница 26: ...p if programmed or xx if the step is not programmed Select the first step in the sequence then press the ENT key The cursor moves to the Memory field Use the cursor keys to select one of the programme...

Страница 27: ...ld Use the cursor keys to select the required memory number 1 12 Press the ENT key to assign the memory to the selected step The cursor returns to the Step field Use the cursor keys to select the next...

Страница 28: ...ut Stopping a Sequence Select the sequence that is currently running in the dimmer using the cursor keys then press the ENT key The sequence will stop running ChilliNet Mode This option allows you to...

Страница 29: ...y or sequence for that area currently being output by the dimmer Stopping a Sequence Select the sequence that is currently running in the dimmer using the cursor keys then press the ENT key The sequen...

Страница 30: ...from the Sequences menu and press the ENT key the screen shows Select Sequence 1 Use the numeric keypad or cursor keys to select the required sequence then press the ENT key the screen shows Push ENT...

Страница 31: ...ats option from the menu and press the ENT key The screen shows Push ENT key to Clear Preheats Press the ENT key to set all the channel preheat levels to 0 Dimmer Laws You can choose a dimmer law for...

Страница 32: ...le loads off a dimmer channel may cause damage to both the load device and Chilli Pro The Switch dimmer law is not a relay and should only be used to switch dimmable loads Set Laws This option allows...

Страница 33: ...press the ENT key The screen shows Push ENT key to reset all laws Press the ENT key to set the state of all Triac laws to normal and Relay Laws to Switched The screen will briefly show a confirmation...

Страница 34: ...key to move between the Channel and Level fields and adjust the values using the numeric keypad or cursor keys Clear Topsets This option allows you to clear reset the topset levels for all the dimmer...

Страница 35: ...Select the Reset Dimmer option from the top level options menu and press the ENT key The screen shows Push ENT key to Reset Dimmer Press the ENT key The screen shows Press ENT key to Confirm Reset Pre...

Страница 36: ...creen shows DMX Address xxx Enter the DMX address using the numeric keypad or cursor keys then press the ENT key This sets the start address for the dimmer The screen pauses briefly and then returns t...

Страница 37: ...atch This option allows you to reset the start DMX address for the dimmer to DMX channel 1 Select the Reset DMX Patch option from the menu and press the ENT key The screen shows Push ENT key to Reset...

Страница 38: ...ixed together DMX HTP Mix The DMX Input signal is mixed on a HTP highest takes precedence basis with the manual control and memory or sequence levels to give the final output levels DMX Takes Preceden...

Страница 39: ...ng the required fail mode and pressing the ENT key the screen returns to the DMX Input screen DMX Input ChilliNet Mode Select the DMX Input option from the menu and press the ENT key The screen shows...

Страница 40: ...ess the ESC key to move on to the DMX Fail Mode screen DMX FAIL MODE Hold DMX This screen allows you to set the DMX Fail Mode for the dimmer Select the required DMX Fail Mode for the area as follows H...

Страница 41: ...outputting the backup memory the outputs fade to that memory If the dimmer is outputting a different memory or sequence the outputs will fade or snap to the memory or sequence In Standard mode the ab...

Страница 42: ...nd unlocked manually by entering a four digit code Global Unlock Code There is a global unlock code which will unlock the Chilli Dimmer If the code to unlock the dimmer has been forgotten contact Zero...

Страница 43: ...and then press the ENT key If the correct code is entered the dimmer is unlocked and the screen shows the first screen in the top level menu structure Manual Control If an incorrect code is entered an...

Страница 44: ...numeric keypad or cursor keys Press the ENT key to confirm The dimmer number is checked against other dimmers on the network The screen shows Verifying Dimmer No If the dimmer number is valid the scr...

Страница 45: ...om the menu and press the ENT key The screen shows Channel 1 Area 1 The cursor is in the Channel field Press the ENT key to move between the Channel and Area fields and adjust the values using the cur...

Страница 46: ...e Alarm On message is repeated every 5 seconds while the Alarm Input remains active Alarm Input Inactive When the dimmer s Alarm Input changes from active to inactive the following will occur The dimm...

Страница 47: ...The screen shows the main screen Alarm State When the dimmer is in the Alarm State the output levels are subject to topset but not temperature shutdown Manual control levels memories sequences prehea...

Страница 48: ...annel output bypasses the dimming circuitry and is fed from the mains supply This therefore allows you to connect non dimmable loads to this channel s output such as moving lights or LED fixtures Non...

Страница 49: ...y cards powered from each primary to provide all 24 channels as relays When using relays channels the channels must be configured to use a Switch dimmer law in the dimmer settings Click here for more...

Страница 50: ...the power supply to the dimmer is isolated before commencing this procedure Observe precautions for handling Electrostatic Sensitive Devices Zero 88 Chilli Pro Page 50 of 60 Printed 23 03 2021 09 13...

Страница 51: ...ect the law Switch 9 Press Enter to confirm and repeat for all necessary channels 2 Remove the front cover s by removing the screws on the front of the unit Retain all screws as they will be required...

Страница 52: ...be assembled at the middle position then the thermal sensor is required If a relay card is to be assembled to the top or bottom position then the thermal sensor must be removed from the board by cutti...

Страница 53: ...the front cover s by removing the screws on the front of the unit Retain all screws as they will be required for reassembly 3 Before assembling it to the unit fit the following wires to the power sup...

Страница 54: ...first circuit breaker Screw the other end of the blue Neutral wire into 1 One of the Neutral DIN terminal blocks if a non RCD version Chilli 2 The phase one RCD if the Chilli has RCDs fitted Zero 88 C...

Страница 55: ...ottom position then the thermal sensor must be removed from the board by cutting its pins 11 Slide the Relay Board into position ensuring the side of the PCB is located in the retaining slot and inser...

Страница 56: ...If you hear a relay buzzing the channel dimmer law hasn t been set to Switch See step 1 Doc No 9850 000377 00 Zero 88 Chilli Pro Page 56 of 60 Printed 23 03 2021 09 13 40 ES...

Страница 57: ...12 Channel 16A 192A 64A per phase 3 phase star 24 Channel 10A 240A 80A per phase 3 phase star 24 Channel 16A 384A 128A per phase 3 phase star Channel Capacity Minimum 0 1A Maximum 10A 16A Rise Time 10...

Страница 58: ...Pro 24 Height 1000mm Width 632mm Depth 155mm Weight 50kg max IP Rating IP2X indoor use only Environmental Operating Temperature Range 5 C to 40 C Operating Relative Humidity 5 to 95 Non condensing Al...

Страница 59: ...EMC Emissions EN55015 2000 A1 2001 A2 2002 Immunity EN61000 6 1 2001 EN61000 6 3 2001 Electrical Safety EN60950 1 2002 Zero 88 Chilli Pro Page 59 of 60 Printed 23 03 2021 09 13 40 ES...

Страница 60: ...l to support zero88 com or through our support forum at zero88 com forum For more urgent requests please contact Zero 88 by telephone on 44 0 1633 838088 24 hour answer service available Zero 88 Chill...

Отзывы: