The voltage is not in the normal 
range. 

Switch off power and restart 
when power is normal 

The compressor runs but 
inner liner does not get cold 

The refrigerant has leaked. 

Contact your local dealer. 
 

The system is blocked. 

The inner liner is very cold 
and the compressor runs 
continuously. 
 

The ice layer on the evaporator is 
too thick. 

Defrost. 
 

The door is being opened and 
closed too frequently. 

The door should be opened 
as little as possible. 

The freezer is overloaded. 

Remove some product. 

The condenser is not well-
ventilated. 
The controller is faulty 

Select a well-ventilated 
place. 
 

The temperature-sense is faulty.  

Contact the local dealer. 

The ambient temperature is too 
high and the thermostat is set too 
low. 

The thermostat should be set 
higher use as a Freezer. 

The compressor does not run. 
 

“+” and “-” are switched. 

Rectify. 

The controller is faulty (the power 
indicator is not on). 

Contact your local dealer. 

The thermostat is set too high; the 
ambient temperature is too low. 

Use as a freezer. 

The freezer is noisy. 
 

The freezer is not level. 

Make the freezer level. 

Some parts come loose. 

Contact your local dealer 

The pipes are touching. 

Contact your local dealer. 

Temperature controller 
displays “OC” 

Sensor damaged. 

Contact your local dealer 

The thermostat is faulty. 

Temperature controller 
displays “SC ” 

Sensor damaged. 

Contact your local dealer 

The thermostat is faulty. 

     

 

 

Main technical parameter 

  
Model 

Z40AC/DC 

 

 

 

 

Efficient volume: 

40 L 

 

 

 

 

Input power: 

70W 

 

 

 

 

Temperature 
range: 

10~-22℃ 

 

 

 

 

Dimension (L x D 
x Hmm): 

625x460x520 

 

 

 

 

 Safety: 

A separate earthed 15A socket outlet should be used on 230V AC and at least a 120W DC socket on 

12V or 24V DC. 

Voltage range: 100volts -240volts 

If AC voltage has been unstable, wait three minutes before restarting.  

when both AC and DC are connected, the freezer will run on AC power. 

Allow approximately 3

5 minutes for start up on 12Vwhen AC power is disconnected. 

In the event of any malfunction of your freezer, please contact the nearest service agent. 

The appliance may be connected to more than one source of energy (AC or DC). 

Caution: 