 Technical Specification

7367000\P3\3

Analogue - 8 pin DIN 

(on the front panel)

Pin     1        Channel  1

          2                        2
          3                        3
          4                        4
          5                        5
          6                        6
          7                        Supply Voltage
          8                        0 volts Reference

DMX - XLR 5 

(on the front panel)

Pin   1                        0v

       2                        Data -
       3                        Data +
       4                        Not connected
       5                        Not connected

Zero 88 Lighting Ltd

, Usk House, Llantarnam Park, Cwmbran, Gwent NP44 3HD, U.K. 

Tel: +44 (0)1633 838088

 

(24hr Answerphone)

  

Fax:  +44 (0)1633 867880 

 

 email: sales

@

zero88.com.

www.zero88.com.

                 Manual Stock Number: 7367000
                     Third Issue - October 1998.

 Zero 88 Lighting Ltd reserves the right to make changes to the equipment described in this manual without prior notice.   
      This equipment is designed for professional stage lighting control, and is unsuitable for any other purpose.
                  It should be used by, or under the supervision of, an appropriately qualified or trained person. 

                         

 E&OE.  Zero 88 reserves the right to change the specification without prior notice.

Electrical

The Betapack 2 range is designed to operate on 230v
+ 10 % - 15% ac supplies at 50Hz.  The packs will not
operate satisfactorily outside these specifications.

The packs may be wired:
Single Phase: 60A 1 phase 2 wire 230v
(255v max phase to neutral).
Earth leakage less than 1mA.

Three Phase Star: 20A 4 230/380v
(255v max phase to phase).wire 
Earth leakage less than 1mA.

Three Phase Delta: 30A 3 wire 230v.
(255 max phase to phase).
Earth leakage less than 4mA.
Max total load: 13.9kW @ 230v.
Load per channel: 0.1A Min; 10A Max
No load consumption: 10w

If used in conjunction with MCBs, to avoid nuisance
tripping use high inrush current (Type K) MCBs .

Input Signals: 0 to + 10v or 0 to -10v, autosensing.

Desk Supply is +/- 20v nominal at 100 mA.
Polarity is set by a switch on the front panel.

Input Impedance: not less than 50kW

Physical

Max Operating Temperature: 40º C Ambient
Size: Free Standing:   447 x 177 x 195mm

                                   (17.5 x 7 x 7.7 inches)

Rack Mounted:            483 x 177 x 195mm

                                   (19 x 7 x 7.7 inches)

Wall Mounted:             483 x 177 x 240mm

                                   (19 x 7 x 9.5 inches).

Net Weight:                 8 kg (17.6lbs).

Portable Appliance Testing

WARNING

 The Betapack 2 will fail the portable

appliance high voltage test as it has capacitors
connected between Live 1 and Earth and between
Neutral and Earth to enable it to comply with CE
regulations.

Fusing

Channel Outputs

11/4” Fuses

Where appropriate ONLY use 11/4” x 1/4” (32 x
6.3mm) 10A rapid (F) HRC ceramic fuses (Zero 88
Part No 40-110-00).

DO NOT USE 

Ultra rapid (FF) or time delay (T) (Anti

Surge) fuses.

Cartridge Fuses

Cartridge type fuseholders use 10.3mm x 38mm 10A
HRC Ceramic fuses (Zero 88 Part No 40-120-00). 

Neutral Disconnect

Breakers and Cartridge fuse versions isolate the live
and neutral when tripped or open.

Fusing of Inductive Loads

All inductive loads (eg. pinspots, any transformer
driven lamp) must be fitted with a separate fuse of the
correct value per lamp or fitting.

Failure to fit the correct fuse may mean that any
supply disturbances could destroy the lamp
transformer.

For a single pinspot, a 500 mA Quick Blow or 250mA
AntiSurge fuse should be used.