TEMPERATURE REGULATION
The exclusive HPDC® cooling system (optional), allows to get cold water in just 5 minutes from power on.
The value set by the factory is 8°C, but it is possible to modify the temperature of the water adjusting the thermostat
positioned behind the frontal panel of the machine (RFP240-260) or on the back of the product (RFP 080).
ANY OPERATION INSIDE THE MACHINE HAS TO BE DONE EXCLUSIVELY BY COMPETENT AND
AUTHORIZED TECHNICIAN AND NEVER BEFORE POWER OFF.
COOLING CIRCUIT MAINTENANCE
The cooling system requires no maintenance. Leave a gap of at least 5 cm on each side. This gap must be at least 25
cm by the ventilation slots. Periodically check that the ventilation slots are clear and not obstructed, then remove any
impurity deposited on the ventilation slots using a brush or a vacuum cleaner.
CAUTION: Failure to clean the condenser and poor ventilation of the cooling circuit can cause the
compressor to overheat and break. These causes invalidate the WARRANTY and any repair cost will be
charged.
(130)
WATER CIRCUIT MAINTENANCE
Cleaning should take place at the following times:
The first time the product is installed (dispense some water for at least a couple of minutes)
When parts or pieces in contact with water are replaced
When pollution is suspected or has occurred. This may manifest itself as a bacterial infection with a bad
smell/taste of the water or if the water is cloudy.
Any new installation
If system has not been used for 5 days