26 - D2O RG1 Product Manual
7.1 TECHNICAL SPECIFICATIONS
7.2 REGULATORY & RADIATION INFORMATION
The Zepiro D2O has the following approvals & listings:
•
AS/NZS CISPR 32 : 2015 (EN55032) Class B and AS/NZS 2772.2: 2011 for RCM Labelling
NOTICE: This equipment complies with the ACMA Radio-communications (Electromagnetic Radiation -
Human Exposure) standard 2014 for General Public Exposure. A minimum of 9 centimetres separation
between the device and the user and all other persons should be maintained
WARNING: Changes or modifications to this device not expressly approved by Zepiro could void the
user’s authority to operate this equipment
ENVIRONMENTAL
Operating Temperature Range
-15 to +60°C (+5 to + 140°F)
Enclosure Ingress Protection (IP) Rating
IP67 (Pending Testing)
POWER
Nominal Operating Voltage
3.0 to 3.6VDC
Max System Standby Current
60µA TBC (with Pulse Contact Open)
Nominal Non-Rechargeable Battery Capacity
10Ah
RADIO
FREQUENCY
Transmit Frequency (VHF)
161.45MHz
Receive Frequency (UHF)
400.575MHz
GNSS Receive Frequency
1571 to 1606MHz
INPUTS
Pulse Input with 30µA Bias - Normally Open (NO) Contact
1
Pulse Max Signal Low Level
500mV
Pulse counter can be externally biased up to
5V
Pulse Signal Type
Active Low Momentary
Pulse Length
3 to 100ms
Burst Pulse Rate
5Hz
Maximum hourly rainfall rate
819.2mm/h
Maximum total count before roll-over to zero
52,428.8mm
SYSTEM
Device Internal Temperature Sensor Range
-30 to +70°C (-22 to + 158°F)
Tamper Detection
Yes
Wire Fault Detection
Yes
MECHANICAL
Securing Fastener
M5 Hex Head Grub Screw (2.5mm Key)
Enclosure Materials
ASA, PMMA, TPE