background image

15

Vortex Use, Care, and Installation Guide

ZEPHYRONLINE.COM

Installation Instructions

Ductless Recirculation

Ductless recirculation is intended for applications where an exhaust duct work is not possible to be 
installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. 
Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is 
then purified and re-circulated back within the home.

We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new 
duct work, if possible. The hood is most effective and efficient as an exhaust hood. Only when the 
exhaust option is not possible should you recourse to converting the hood into a recirculating hood.

When converted to be a recirculating hood, a set of charcoal filters are required on top of its standard 
Metal Filter set. Order according to its part number below. The standard mesh filters are intended to 
capture residue from cooking, and the optional charcoal filters help to purify fumes exhausted from 
cooking for recirculation.

Recirculating Kit Installation 

(required if no ducting is used)

For detailed installation instructions, please refer to the manual included with the recirculating kit. 

Hood Model

Part Number

Quantity to Order

AK9028BS

ZRC-9000

1

AK9034BS

ZRC-9000

1

1.  Purchase recirculating kit per the part number above.  

Remove filter from hood. Place charcoal filter on back  
side of filter.

2.  Place filter brackets over charcoal filter and secure in  

place by tucking each end of bracket under the filter 
frame. FIG. E. Reinstall filter.

 

Order replacement charcoal filters as follows:

Hood Model

Part Number

Quantity to Order

AK9028BS

Z0F-C090

1

AK9034BS

Z0F-C090

1

DO NOT WASH CHARCOAL FILTERS. Charcoal filters may need to be changed more often depending 
on cooking habits.

FIG. F

Содержание Vortex AK9028BS

Страница 1: ...WWW ZEPHYRONLINE COM APR21 0101 Vortex AK9028BS AK9034BS EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Страница 2: ...2 Vortex Use Care and Installation Guide VORTEX INSERT CORE...

Страница 3: ...cting Calculation Sheet 8 Mounting Height Clearance Ducting 9 Ducting Options 10 Hood Speci cations 11 Electrical Supply 12 Cable Lock 12 Hood Preparation Installation 13 Mounting the Hood 14 Ductless...

Страница 4: ...locked securely fasten a prominent warning device such as a tag to the service panel General Safety WARNING Warning means that failure to heed this safety statement may result in extensive product dam...

Страница 5: ...walls ceilings attics crawl spaces or garages WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be don...

Страница 6: ...al Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a sepa...

Страница 7: ...Not Supplied Ducting conduit and all installation tools Cable locking connector if required by local codes Optional recirculating kit ZRC 9000 Parts Supplied Quantity Part 1 Power pack 1 Adjustable f...

Страница 8: ...Ft Ft 6 7 8 10 Round roof cap 30 Ft x Ft Subtotal column2 Subtotal column1 Total ductwork Maximum Duct Length For satisfactory air movement the totalductlengthshould not exceed 150 equivalent feet 6 r...

Страница 9: ...and 20 above electric cooktops Maximum mount height should be no higher than 36 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and...

Страница 10: ...screws and tape all joints w certi ed Silver Tape or Duct Tape Fire Hazard NEVER exhaust air or terminate ductwork into spaces between walls crawl spaces ceilings attics or garages All exhaust must b...

Страница 11: ...ation Guide ZEPHYRONLINE COM Installation Instructions 10 3 8 1 1 8 5 16 2 1 16 17 1 2 min 17 1 2 max 20 3 8 19 8 9 16 5 1 2 6 2 11 16 4 7 8 26 9 16 13 30 29 1 8 36 35 1 16 12 5 16 13 1 2 30 28 3 8 36...

Страница 12: ...ord or adapter plug with this appliance Follow national electrical codes or prevailing local codes and ordinances This appliance requires a 120V 60Hz electrical supply and connected to an individual p...

Страница 13: ...IG C page 14 4 Install hood into cabinet FIG D page 14 NOTE Wood blocking may need to be added to cabinet base if additional support is needed 5 Secure front panel to cabinet FIG E page 14 6 Finalize...

Страница 14: ...2 Remove lm from double sided tape on the sides of front panel FIG E1 3 Lift front panel up and slide into the nose of the cabinet base The tape will temporarily hold it in place and help keep the bo...

Страница 15: ...coal lters are required on top of its standard Metal Filter set Order according to its part number below The standard mesh lters are intended to capture residue from cooking and the optional charcoal...

Страница 16: ...16 Vortex Use Care and Installation Guide VORTEX INSERT CORE Features Controls 0 I I I I I I Blower On O 1 2 0 I I I BLOWER ON OFF SPEED SELECTION LIGHTS OFF DIM BRIGHT 1 2 Slide Controls...

Страница 17: ...on abrasive stainless steel polish cleaners to polish and buff out the stainless luster and grain Always scrub lightly with clean cotton cloth or micro ber cloth and buff in the direction of the stain...

Страница 18: ...the unlikely event that your LumiLight LED fails please contact Zephyr to order replacement parts See the list of parts and accessories page for part numbers and contact information LED Removal FIG H...

Страница 19: ...tion Guide ZEPHYRONLINE COM Wiring Diagram AK9028BS AK9034BS Wiring Diagram Volts Hz Max Amps 120 60 4 B W BLUE BROWN BLACK MOTOR BLACK BLUE BROWN GREY B W B W BLACK RED WHITE WHITE WHITE GREEN BODY G...

Страница 20: ...em cool down Damaged capacitor Change the capacitor The motor wire is not connected Make sure the motor wire is plugged into the molex connector The unit is vibrating The blower is not secured in plac...

Страница 21: ...hin 24 to 36 for gas cooktops and 20 to 36 for electric cooktops The wind from the opened windows or opened doors in the surrounding area are affecting the ventilation of the hood Close all the window...

Страница 22: ...t of Parts Accessories Description Part Number Replacement Parts LumiLight LED 6W Z0B0050 Baffle Filter each 50210016 Optional Accessories Recirculating Kit ZRC 9000 Charcoal Filter Replacement Z0F C0...

Страница 23: ...r to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE L...

Страница 24: ...moment to register your new Zephyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one...

Страница 25: ...WWW ZEPHYRONLINE COM APR21 0101 Vortex AK9028BS AK9034BS EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Страница 26: ...2 Vortex Guide d utilisation d entretien et d installation INS RER CORE VORTEX...

Страница 27: ...duit d a ration 8 Hauteur de montage d gagement et gaine 9 Options de conduits 10 Sp ci cations de la hotte 11 Fourniture lectrique 12 Raccord de c ble 12 Pr paration et installation de la hotte 13 Mo...

Страница 28: ...b Avant l entretien ou le nettoyage de l unit coupez l alimentation au panneau de service et verrouillez les moyens de d connexion de service pour viter toute mise sous tension accidentelle Lorsque le...

Страница 29: ...rmes applicables y compris la construction r sistant au feu b Une quantit d air suffisante est n cessaire pour une combustion et une vacuation correctes des gaz par le conduit de fum e chemin e de l q...

Страница 30: ...t ad quate et conforme au National Electrical Code ANSI NFPA 70 derni re dition ou aux normes CSA C22 1 94 Code canadien de l lectricit partie 1 et C22 2 No 0 M91 derni re dition et tous les codes et...

Страница 31: ...d installation Connecteur de verrouillage de c ble si requis par les codes locaux Kit de recirculation en option ZRC 9000 Pi ces fournies Quantit Partie 1 Bloc d alimentation 1 Panneau avant r glable...

Страница 32: ...e utilis rect droit circ droit rect coude 90 rect coude 45 rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air convenable la...

Страница 33: ...s de cuisson gaz et 20 po au dessus des tables de cuisson lectriques La hauteur de montage maximale ne doit pas d passer 36 po Table de cuisson lectrique Min 20 po Max 36 po 36 po Table de cuisson au...

Страница 34: ...avec du ruban argent ou du ruban adh sif Risque d incendie NE JAMAIS vacuer l air ni terminer de conduits dans des espaces entre les murs les vides sanitaires les plafonds les greniers ou les garages...

Страница 35: ...tructions d installation 10 3 8 po 1 1 8 po 5 16 po 2 1 16 po 17 1 2 po min 17 1 2 po max 20 3 8 po 19 8 9 16 po 5 1 2 po 6 po 2 11 16 po 4 7 8 po 26 9 16 po 13 po 30 po 29 1 8 po 36 po 35 1 16 po 12...

Страница 36: ...rivation individuel correctement mis la terre prot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blage doit tre 2 ls avec terre Veuillez galement vous r f rer au sch ma lectriqu...

Страница 37: ...E Des blocs de bois peuvent devoir tre ajout s la base de l armoire si un support suppl mentaire est n cessaire 5 Fixez le panneau avant l armoire FIG E page 14 Finaliser l lectricit et les conduits 6...

Страница 38: ...tirez le lm du ruban adh sif double face sur les c t s du panneau avant FIG E1 3 Soulevez le panneau avant et faites le glisser dans le nez de la base de l armoire Le ruban le maintiendra temporaireme...

Страница 39: ...bon est requis en plus de son ensemble de ltres m talliques standard Commandez selon son num ro de pi ce ci dessous Les ltres mailles standard sont destin s capturer les r sidus de cuisson et les ltre...

Страница 40: ...ilateur Marche Arr t Choix de Vitesse 1 Lumi res teindre Veilleuse Forte intensit 2 0 I I I Ventilateur Marche Arr t Choix de Vitesse 0 l appareil est teint I quivaut la vitesse lente II la vitesse mo...

Страница 41: ...le nettoyage utilisez un produit de polissage nettoyant pour acier inoxydable non abrasif pour polir et polir le lustre et le grain de l acier inoxydable Frottez toujours l g rement avec un chiffon e...

Страница 42: ...LumiLight LED tombe en panne veuillez contacter Zephyr pour commander des pi ces de rechange Consultez la page de la liste des pi ces et accessoires pour les num ros de pi ces et les coordonn es 1 Re...

Страница 43: ...d installation ZEPHYRONLINE COM Sch ma de c blage AK9028BS AK9034BS Sch ma de c blage Volts Hz Max Amps 120 60 4 N B BLEU MARRON NOIR MOTEUR NOIR BLEU MARRON GRIS N B N B NOIR ROUGE BLANC BLANC BLANC...

Страница 44: ...z le condensateur Le l du moteur n est pas connect Assurez vous que le l du moteur est branch sur le connecteur molex L unit vibre Le ventilateur n est pas x en place Serrez le ventilateur en place Ro...

Страница 45: ...les tables de cuisson au gaz et entre 20 po et 36 po pour les tables de cuisson lectriques Le vent des fen tres ouvertes ou des portes ouvertes dans la zone environnante affecte la ventilation de la...

Страница 46: ...ces et accessoires La description Num ro d article Pi ces de rechange LumiLight LED 6W Z0B0050 Filtre d ecteur chacun 50210016 Accessoires optionnels Kit de recirculation ZRC 9000 Remplacement du ltre...

Страница 47: ...tous les frais de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE RECOURS SOUS LA P...

Страница 48: ...it au www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il assure la couvertu...

Отзывы: