background image

30

Titan Island Use, Care, and Installation Guide

T I TA N   I S L A N D

WA L L

P R O

List of Parts & Accessories

Description

Part Number

Replacement Parts

Swivel LumiLight LED, 6W

Z0B0052

Pro Baffle Filter (each)

50210036

Optional Accessories

Dual Internal Blower

PBD-1300B

Make-up Air Kit (Single Blower)

MUA008A

Make-up Air Kit (Dual Blower)

MUA010A

RF Remote Control

14000005

Duct Cover Extension 
(36" & 42")

Z1C-0077

Duct Cover Extension 
(48" & 54")

Z1C-0177

To order parts, visit us online at http://store.zephyronline.com.

Содержание Titan AK7754BS

Страница 1: ...WWW ZEPHYRONLINE COM FEB23 0201 Airflow Control Technology TM C Titan Island AK7736BS AK7742BS AK7748BS AK7754BS EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Страница 2: ...2 Titan Island Use Care and Installation Guide TITAN ISL AND WALL PRO...

Страница 3: ...ounting Height Clearance Ducting 9 10 Ducting Options 11 Hood Specifications 12 Electrical Supply 13 Cable Lock 13 Mounting the Hood 14 16 PBD 1300B Dual Blower Installation 17 18 Features Controls 19...

Страница 4: ...e locked securely fasten a prominent warning device such as a tag to the service panel General Safety WARNING Warning means that failure to heed this safety statement may result in extensive product d...

Страница 5: ...within walls ceilings attics crawl spaces or garages WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring mus...

Страница 6: ...and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire with ground Please also refer to Electrical Diag...

Страница 7: ...are package 4 www zephyronline com List of Materials 4 www zephyronline com MODELS AK7736AS AK7742AS AK7748AS PARTS SUPPLIED 6 x 1 4 M4 x 8 14 M4 x 10 16 3 16 7 8 4 6 x 1 1 2 4 6 x 2 4 1 Hood 4 Duct c...

Страница 8: ...Ft Ft Ft 6 7 8 10 Round roof cap 30 Ft x Ft Subtotal column2 Subtotal column1 Total ductwork Maximum Duct Length For satisfactory air movement the totalductlengthshould not exceed 150 equivalent feet...

Страница 9: ...ion Instructions Mounting Height Clearance Ducting min A max B Standard Extension Hood Heights Duct Cover Duct Cover minimum ducted A 32 1 2 49 maximum B 50 78 Ceiling Heights minimum ducted C 92 1 2...

Страница 10: ...mum mount height between range top to hood bottom should be no less than 24 Maximum mount height should be no higher than 36 It is important to install the hood at the proper mounting height Hoods mou...

Страница 11: ...ns with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Fire Hazard NEVER exhaust air or terminate ductwork into spaces between walls crawl spaces ceilings attics or garage...

Страница 12: ...iew 35 15 16 36 41 15 16 42 47 15 16 48 53 15 16 54 17 15 16 36 42 21 5 8 48 54 4 3 5 16 16 27 15 16 14 5 16 31 5 8 Standard Min 32 1 2 Max 50 Z1C 0077 36 42 Z1C 0177 48 54 Min 49 Max 78 C L C L 7 7 8...

Страница 13: ...cord or adapter plug with this appliance Follow national electrical codes or prevailing local codes and ordinances This appliance requires a 120V 60Hz electrical supply and connected to an individual...

Страница 14: ...wall to reinforce the mounting location FIG B1 Secure 2 M6 x 2 wood screws to points A and B of the paper template FIG C Do not completely tighten screws leave approximately 1 4 exposed 2 Remove screw...

Страница 15: ...rds to the unit FIG E3 Install 4 M4 x 8 screws to secure the diagonal support brackets onto the frame 4 Lift support frame assembly up to the ceiling making sure the word front on the top support fram...

Страница 16: ...ood and reposition electronics mounting bracket with 2 M4 x 8 screws Install electrical and duct work 7 Power up hood verify all functions and check for leaks around duct tape 8 Assembly top duct cove...

Страница 17: ...vertical ducting to dual blower vertical ducting please follow the instructions below 1 Disconnect blower plug and white and black power cables 2 Remove 4 screws from interior of hood body attaching s...

Страница 18: ...ual blower by 4 screws previously removed from step 2 6 Attach 10 round blower collar to top of hood body by 4 M4x8 screws 7 Attach dual blower PCB to electronics bracket by 4 screws Refer to wiring d...

Страница 19: ...CFM With hood off hold the On Off button for three seconds The Display will show if ACT is disabled and set to the maximum CFM or if ACT is enabled and set to one of the restricted maximum CFM levels...

Страница 20: ...words CleanAIr Function Deactivated will illuminate indicating the function has been disabled When the Clean Air Function is enabled the fan will turn on speed 1 for 10 minutes every 4 hours of non f...

Страница 21: ...erence that may cause undesired operation Synchronization To create a unique link between your hood and remote control please follow these steps 1 With hood off press and hold the Lights button on the...

Страница 22: ...utlet for easy storage Note The remote holder does not charge the RF remote Maximum remote control communication distance is 15 feet from the liner RF Remote Maintenance Clean the remote control using...

Страница 23: ...stainless steel grain To remove heavier grease build up use a liquid degreaser detergent After cleaning use a non abrasive stainless steel polish cleaners to polish and buff out the stainless luster...

Страница 24: ...748BS AK7754BS 50210036 6 1 2 3 1 2 3 FIG K Swivel LumiLight LED In the unlikely event that your swivel LumiLight LED fails please contact Zephyr to order replacement parts See the list of parts and a...

Страница 25: ...blower speed to one of three most commonly specified CFM levels 590 390 or 290 CFM The usage of ACT may not be necessary for your installation Please check your local codes for CFM restrictions ACT is...

Страница 26: ...n To verify if your installer enabled ACT 1 With hood off hold the On Off button for three seconds The Display will show if ACT is disabled and set to the maximum CFM or if ACT is enabled and set to o...

Страница 27: ...BLACK BLACK BLACK BLACK BLACK BLACK B W WHITE WHITE WHITE WHITE WHITE GREEN BODY MOTOR 1 MOTOR 2 WHITE K RED RED B W 48 and 54 models only Single Blower Dual Blower B LED PCB wire C Power wire for exp...

Страница 28: ...is plugged into the molex connector The thermally protected system detects if the blower is too hot to operate and shuts the blower down The blower will function properly after the thermally protected...

Страница 29: ...the duct work or duct opening The unit turns on by itself Remote control may be paired incorrectly Resynchronize the remote control to connect to a different channel Filter is vibrating Filter is loo...

Страница 30: ...LumiLight LED 6W Z0B0052 Pro Baffle Filter each 50210036 Optional Accessories Dual Internal Blower PBD 1300B Make up Air Kit Single Blower MUA008A Make up Air Kit Dual Blower MUA010A RF Remote Contro...

Страница 31: ...er to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE...

Страница 32: ...e a moment to register your new Zephyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than...

Страница 33: ...WWW ZEPHYRONLINE COM FEB23 0201 Airflow Control Technology TM C Titan Island AK7736BS AK7742BS AK7748BS AK7754BS EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Страница 34: ...2 Titan Island Guide d utilisation d entretien et d installation TITAN ISL AND LE PRO...

Страница 35: ...de montage d gagement et gaine 9 10 Options de conduits 11 Sp cifications de la hotte 12 Fourniture lectrique 13 Raccord de c ble 13 Montage de la hotte 14 16 Installation du double ventilateur PBD 1...

Страница 36: ...b Avant l entretien ou le nettoyage de l unit coupez l alimentation au panneau de service et verrouillez les moyens de d connexion de service pour viter toute mise sous tension accidentelle Lorsque l...

Страница 37: ...et normes applicables y compris la construction r sistant au feu b Une quantit d air suffisante est n cessaire pour une combustion et une vacuation correctes des gaz par le conduit de fum e chemin e d...

Страница 38: ...e une alimentation lectrique de 120 V 60 Hz et est connect un circuit de d rivation individuel correctement mis la terre prot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blage...

Страница 39: ...ames 1 upper 1 lower 2 Angled support brackets 1 Middle support frame 4 Baffle filters AK7736AS AK7742AS 6 Baffle filters AK7748AS 2 LED light bulbs AK7736AS AK7742AS 4 LED light bulbs AK7748AS 1 8 in...

Страница 40: ...ombre utilis rect droit circ droit rect coude 90 rect coude 45 rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air convenable...

Страница 41: ...agement et gaine min A max B Recouvrement de Prolongement de Hauteur de la hotte conduit standard rec de conduit min avec conduit A 32 1 2 po 49 po maximum B 50 po 78 po Hauteur de plafond min avec co...

Страница 42: ...tre les deux La hauteur minimale de montage entre le haut de la cuisini re et le bas de la hotte ne doit pas tre inf rieure 24 po La hauteur de montage maximale ne doit pas d passer 36 po Il est impor...

Страница 43: ...les joints avec du ruban argent ou du ruban adh sif Risque d incendie NE JAMAIS vacuer l air ni terminer de conduits dans des espaces entre les murs les vides sanitaires les plafonds les greniers ou...

Страница 44: ...po 54 po 4 po 3 5 16 po 16 po 27 15 16 po 14 5 16 po 31 5 8 po La Norme Min 32 1 2 po Max 50 po Z1C 0077 36 po 42 po Z1C 0177 48 po 54 po Min 49 po Max 78 po C L C L 7 7 8 po 18 po 36 po 20 15 16 po 4...

Страница 45: ...rivation individuel correctement mis la terre prot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blage doit tre 2 fils avec terre Veuillez galement vous r f rer au sch ma lectri...

Страница 46: ...s che pour renforcer l emplacement de montage FIG B1 Fixez 2 vis bois M6 x 2 po aux points A et B du gabarit en papier FIG C Ne serrez pas compl tement les vis laissez environ 1 4 po expos 2 Retirez l...

Страница 47: ...unit FIG E3 Installez 4 vis M4 x 8 pour fixer les supports de support diagonaux sur le cadre 4 Soulever l assemblage du cadre de support jusqu au plafond en s assurant que le mot avant sur le cadre de...

Страница 48: ...fonctions et recherchez les fuites autour du ruban adh sif 8 Assemblez les couvercles de conduit sup rieurs avec des trous d a ration sur le cadre de support sup rieur Fixez ensemble les couvercles d...

Страница 49: ...deux ventilateurs veuillez suivre les instructions ci dessous 1 D branchez la fiche du ventilateur et les c bles d alimentation blanc et noir 2 Retirez les 4 vis de l int rieur du corps de la hotte fi...

Страница 50: ...c demment retir es l tape 2 6 Fixez le collier de soufflage rond de 10 po au haut du corps de la hotte l aide de 4 vis M4x8 7 Fixez la carte de circuits imprim s du ventilateur double au support lectr...

Страница 51: ...appuyez sur la touche On Off pendant trois secondes Le tableau d affichage indique si la fonction ACT est d sactiv e et ajust e au nombre de pi3 min maximal ou si elle est activ e et ajust e l un des...

Страница 52: ...e tableau d affichage indiquant que la fonction a t d sactiv e Lorsque la fonction d air pur est activ e le ventilateur s allume la vitesse 1 pendant dix minutes pour chaque p riode d inutilisation de...

Страница 53: ...ces tapes 1 Lorsque la hotte est teinte appuyez sur le bouton Lumi res de la hotte et maintenez le enfonc jusqu ce que les commandes affichent Appairage distance 2 Appuyez sur un bouton de la t l com...

Страница 54: ...le Remarque le support de t l commande ne charge pas la t l commande RF La distance de communication maximale de la t l commande est de 15 pieds de la doublure Maintenance distance RF Nettoyez la t l...

Страница 55: ...Pour liminer les accumulations de graisse plus lourdes utilisez un d tergent d graissant liquide Apr s le nettoyage utilisez un produit de polissage nettoyant pour acier inoxydable non abrasif pour p...

Страница 56: ...6 Swivel LumiLight LED Dans le cas peu probable o votre LED LumiLight pivotante tomberait en panne veuillez contacter Zephyr pour commander des pi ces de rechange Voir la page de la liste des pi ces e...

Страница 57: ...imale du ventilateur l un des trois niveaux CFM les plus couramment sp cifi s 590 390 ou 290 CFM L utilisation d ACT peut ne pas tre n cessaire pour votre installation Veuillez v rifier vos codes loca...

Страница 58: ...uton Marche Arr t enfonc pendant trois secondes L cran affichera si ACT est d sactiv et r gl sur le CFM maximum ou si ACT est activ et r gl sur l un des niveaux maximum de CFM restreints de 590 390 ou...

Страница 59: ...NC BLANC VERT CORPS MOTEUR 1 MOTEUR 2 BLANC K ROUGE ROUGE BLANC NOIR Mod les 48 po et 54 po uniquement Souffleur simple Double ventilateur B Fil de circuit imprim LED C C ble d alimentation pour PCB d...

Страница 60: ...necteur molex Le syst me thermiquement prot g d tecte si le ventilateur est trop chaud pour fonctionner et arr te le ventilateur Le ventilateur fonctionnera correctement apr s le refroidissement du sy...

Страница 61: ...uverture du conduit L unit s allume d elle m me La t l commande n est peut tre pas coupl e correctement Resynchronisez la t l commande pour vous connecter un autre canal Le filtre vibre Le filtre est...

Страница 62: ...52 Filtre Baffle Pro chacun 50210036 Accessoires optionnels Double ventilateur interne PBD 1300B Kit d air d appoint ventilateur simple MUA008A Kit d air d appoint double ventilateur MUA010A T l comma...

Страница 63: ...ais de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE RECOURS SOUS LA PR SENTE GAR...

Страница 64: ...duit au www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il assure la couver...