12
www.zephyronline.com
Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re-
circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
work, if possible. The hood is most effective and efficient as an exhaust hood. Only when the exhaust option
is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal filters are required on top of its standard Baffle
Filter set. Order according to its Part number below. The standard Baffle Filters are intended to capture
residue from cooking and the optional charcoal filters help to purify fumes exhausted from cooking for re-
circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
Kit includes charcoal filters, charcoal filter brackets and air diverter plate.
Hood Model
Part No. Filters in Pkg.
ZSI-E30BS
ZRC-00SI 2
ZSI-E36BS
ZRC-00SI 2
1. Secure air diverter plate to wall below duct cover wall bracket.
(FIG.C)
2. Remove baffle filters from hood. Place charcoal filter over the
back side of baffle filter.
3. Secure charcoal filters to back side of baffle filters by three
brackets for each filter.
4. Re-install baffle filters.
5. Turn on charcoal filter change indicator on control panel.
(refer to details on page 14.) The microprocessor in the
controls will indicate the need to change the charcoal filters
after 120 hours of continuous use. Order replacement charcoal
filters per the list below.
NOTE: See manual included with recirculating kit for more
detailed instructions.
Charcoal Filter Replacements
Hood Model
Part No. Qty to Order
ZSI-E30BS
Z0F-C091 2
ZSI-E36BS
Z0F-C091 2
DO NOT WASH CHARCOAL FILTERS. Charcoal filters may need
to be changed more often depending on cooking habits.
Installation –
Ductless Recirculating
FIG C
Содержание Siena
Страница 2: ...www zephyronline com...
Страница 20: ...18 www zephyronline com Fan Curve Diagrams...
Страница 21: ...19 Fan Curve Diagrams...
Страница 26: ...www zephyronline com...
Страница 44: ...18 www zephyronline com Diagrammes des courbes caract ristiques des ventilateurs...
Страница 45: ...19 Diagrammes des courbes caract ristiques des ventilateurs...