background image

11

Lights On/Dim/Off

Display 

(speed level, delay off, filter clean/change)

Adjust 5 Speed Levels

Power / Delay Off

1  POWER / DELAY OFF BUTTON

       Power Button Function

       -      Button will turn power on and off for entire hood (fan and lights).

       - Hood will remember the last speed and light level it was turned off at.

 

(Example: Press      Button to turn off hood when on fan speed 4 and high lights. Press      Button  

 

again and the hood will turn back on at speed 4 and high lights level.)

     

  Delay Off Button Function

       - With the fan on press and hold the      Button for two seconds. The fan will change to speed 1 and the  

         5 minute delay off timer will start.                 

                      +                                          LEDs will illuminate and slowly blink in accordance with the time  

 remaining until the fan and lights automatically turn off.

       - Pressing      Button while Delay Off Function is enabled will turn the hood off and cancel the Delay Off     

         Function.

       ACT Verification

       -  Airflow Control Technology (ACT) allows the installer to set the maximum fan CFM to align with local  

          codes and regulations. 

 

- To verify the maximum fan CFM:

  

        - With hood off, hold the      Button for two seconds. If all five fan speed indicators illuminate =  

  

          default maximum CFM. If four fan speed indicators illuminate = 390 maximum CFM. If 3 fan   

  

          speed indicators illuminate = 290 maximum CFM.

2  SPEED SELECTION BUTTON

       Fan Speed Decrease Button

       - Press this button to decrease fan speed. 5, 4, 3, 2, 1.

       - If fan is On Speed 1 and this button is pressed, fan will power Off.

 

      Fan Speed Increase Button

       - Press this button to increase fan speed. Fan On, 1, 2, 3, 4, 5.

       - If hood is Off and this button is pressed, fan will turn On Speed 1.    

       Act Enabled Speed Selections

       - When ACT is enabled, the number of fan speeds will be reduced as follows:

 

- 390 CFM = Maximum 4 speeds

 

- 290 CFM = Maximum 3 speeds

  

  

 

 

Features & Controls - 

ICON T

ouch Controls

Содержание Siena ZSI-E36AS

Страница 1: ...Use Care and Installation Guide www zephyronline com Model number Serial Number SEP15 0301 2015 Zephyr Ventilation LLC Siena ZSI E30AS ZSI E36AS ZSI E30AS ES ZSI E36AS ES ZSI E30AS ES ZSI E36AS ES...

Страница 2: ...www zephyronline com...

Страница 3: ...ting Options 7 Hood Specifications 8 Mounting the Range Hood 9 Ductless Recirculating 10 FEATURES CONTROLS ICON Touch Controls 11 12 MAINTENANCE Cleaning and Filter Care 13 Light Bulbs 14 TROUBLESHOOT...

Страница 4: ...the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie s...

Страница 5: ...C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified elec...

Страница 6: ...ARDWARE PACKAGE CONTENTS MODELS ZSI E30AS ZSI E36AS ZSI E30AS ES ZSI E36AS ES PARTS SUPPLIED 1 Hood with internal blower 2 Baffle filters 1 Duct cover assembly top and bottom 1 Duct cover wall bracket...

Страница 7: ...lumn 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 r...

Страница 8: ...efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover...

Страница 9: ...the outside unless using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Som...

Страница 10: ...Specifications Top of Hood Side of Hood Front of Hood AC In C L 10 1 2 29 15 16 35 7 8 12 3 8 STANDARD min ducted 27 1 2 min recirc 32 max 42 Z1C 00SI min ducted 46 1 2 min recirc 50 1 2 max 79 8 7 1...

Страница 11: ...s 11 Position electrical outlet within the space covered by the telescopic duct covers and where it will not interfere with the round duct FIG B 12 Install duct work and duct tape 13 Power up hood and...

Страница 12: ...ture residue from cooking and the optional charcoal filters help to purify fumes exhausted from cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Kit includes charcoal filter...

Страница 13: ...ction is enabled will turn the hood off and cancel the Delay Off Function ACT Verification Airflow Control Technology ACT allows the installer to set the maximum fan CFM to align with local codes and...

Страница 14: ...icator disabled by default must be enabled if recirculating hood To enable Charcoal Filter Replacement Reminder With hood off hold button and button simultaneously for two seconds All LED indicators w...

Страница 15: ...taining chlorine bleach Do not use orange cleaners Baffle Filters The baffle filters installed by the factory are intended to filter out residue and grease from cooking They need not be replaced on a...

Страница 16: ...bs are not hot ZSI E30AS ES ZSI E36AS ES Access light bulb by removing light bulb lens cover by 1 screw FIG B Remove by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees st...

Страница 17: ...osition 1 Adjust the filters until the whistling stops 2 The duct pipe connections are not sealed or connected properly 2 Check the duct pipe connections to be sure all connections are sealed properly...

Страница 18: ...AS ES CIRCUIT DIAGRAM USE ONLY 13W GU24 FLUORESCENT LIGHT BULBS MODEL SPS T3 13GUS Power consumption shown for default 400 CFM blower configuration ACT 290 CFM Fan Max 82W 0 74A VOLTS HZ MAX AMPS 120...

Страница 19: ...tension Kit Z1C 00SI To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 ZSI E30AS ZSI E36AS DESCRIPTION PART Replacement Parts Baffle Filter each 50200050 Halog...

Страница 20: ...ter the first year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR...

Страница 21: ...19...

Страница 22: ...our new range hood at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one IT S IMPORTANT Ensures w...

Отзывы: