12
www.zephyronline.com
ACT Conversion
A
LUÀRZ&RQWURO7HFKQRORJ\$&7
Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the
maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits.
$&7HQDEOHVWKHLQVWDOOHUWRHDVLO\VHWWKHPD[LPXPEORZHUVSHHGWRRQHRIWZRPRVWFRPPRQO\VSHFL¿HG&)0
OHYHOVRU&)07KHXVDJHRI$&7PD\QRWEHQHFHVVDU\IRU\RXULQVWDOODWLRQ3OHDVHFKHFN\RXUORFDO
codes
for
CFM
restrictions.
By default the maximum blower CFM is set to 1200.
To enable ACT
1. Before hood installation, gain access to PC board by following the steps shown in FIG. C.
2. Change plastic jumper positioning as shown in FIG. D to set the desired maximum blower CFM.
3. Re-install PC board & continue with hood installation.
4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below
the wiring diagram or in another clearly visible location.
NOTE:
After re-positioning the jumper and powering on the hood, the CFM cannot be changed again.
To verify if your installer enabled ACT
With hood off, press and hold the power button for three seconds. If 5 LEDs illuminate = defualt max. CFM, if 3
LEDs illuminate = max. 590 CFM, and if 2 LEDs illuminate = max. 390 CFM.
When ACT is enabled, the number of blower speeds will be reduced. 590 CFM = max. 3 speeds and 390 CFM =
max. 2 speeds.
There should also be a foil label located inside the hood body near the wiring diagram that indicates the blower
CFM.
PC Board
1
3
5
7
2
4
6
8
Jumper 5-6 or 7-8
DEFAULT POSITION
Default Max. Blower CFM
Jumper 3-4
Max. Blower CFM
590
Jumper 1-2
Jumper Pins
Plastic
Jumper
1
3
5
7
2
4
6
8
1
3
5
7
2
4
6
8
1
3
5
7
2
4
6
8
Max. Blower CFM
390
CAUTION:
Hood must be disconnected from main power prior to performing the
conversion instructions listed below. Failure to do so could result in
personal injury or damage to the product.
!
- PC Board is located behind internal cover panel.
5HPRYHEDIÀH¿OWHUV
- Remove 3 screws attaching internal cover panel.
- Pull down on panel to access PC Board.
FIG. C
FIG. D
Содержание Siena Pro ZSP-E48BS
Страница 2: ...www zephyronline com...
Страница 16: ...14 www zephyronline com Fan Curve Diagrams...
Страница 22: ...www zephyronline com...
Страница 35: ...13 Diagrammes des courbes caract ristiques des ventilateurs ZSP...
Страница 36: ...14 www zephyronline com Diagrammes des courbes caract ristiques des ventilateurs...