Part Descr iption                                        

Part#         

Halogen Bulb G U-10, 120V, 50W

Z0B-0020

s

ei

r

o

s

s

e

c

c

A

d

n

a

st

r

a

P

f

o

t

si

L

Internal Blower, 600 cfm  

 

CBI-600

External Blower, 1000 cfm

CBE-1000

Duct Cover Extension Kit  

 

Z1C-00SH

Accessory Desc r iption                                         Part#         

Содержание Shade CSH -E36SX

Страница 1: ...Shade CSH E36SX CSH E42SX CSH E48SX Use Care and Installation Guide www zephyronline com Model number Serial number Date of Purchase Sales Dealer MAY07 0101 Zephyr Corporation...

Страница 2: ...www zephyronline com...

Страница 3: ...ounting Height and Clearance Ducting Specifications Internal Blower Preparing Hood for External Blower Mounting the Hood FEATURES CONTROLS Controls Overview Door Insert Panel MAINTENANCE Cleaning Ligh...

Страница 4: ...DO NOT USE WATE R includingwet dishcloths or towels a violentsteam explosion will result d Use an extinguisher ONLY if 1 You know you have a class ABC extinguisher and you already know how to operate...

Страница 5: ...while installing 1 Hood Body 2 Baffle Filters 1 36 model 4 GU 10 120V 50W Halogen Bulbs 1 Hood Door 2 Telescopic Duct Covers 1 Ceiling Mounting Bracket 1 HARDWARE PACKET 7 2 wood screws 7 anchors 7 1...

Страница 6: ...nd straight 1 Ft x Ft Subtotal column 1 Duct pieces Total Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft 7 Round wall cap with damper 30 Ft x Ft 7 Round 900 elbow 15 Ft x Ft 7...

Страница 7: ...ble reduce the number or transitions and turns If a reducer is used install a long reducer instead of a pancake reducer Reduce duct size as far away from openingas possible If turns or transitions are...

Страница 8: ...External Blower External Blower WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside...

Страница 9: ...35 7 16 41 7 32 47 1 4 20 10 or 24 10 12 DOOR INSERT PANEL 1 8 3 175 mm thickness 36 inch 31 5 6 42 inch 36 13 16 48 inch 42 7 8 24 5 8 625mm 8 8 12 16 7 8 31 1 4 9 3 16 6 1 5 O 8 5 16 8 1 4 R 2 3 1 1...

Страница 10: ...shown using the provided 1 2 5x15mm screws with washers 3 P osition capacitor box as shown 4 Secure capacitor bo x to hood using the provided 1 2 self tapping screws ATTENTION The following are intru...

Страница 11: ...finish installation of capacitor box Refer to Fig A on previous page 7 Attach short capacitor connector to blower connector 8 Attach long capacitor connector to control board connector 9 Use plastic t...

Страница 12: ...on with external blower model CBE 1000 For instructions on installing internal blower model CBI 600 please turn to page 8 NOTE Please refer to the CBE 1000 manual for external blower mounting instruct...

Страница 13: ...side hood 9 Attach grounding wire from external blower wiring box to grounding screw of the junction box Refer on Fig A in diagram below 10 Final view of external blower preparation Continue to page 1...

Страница 14: ...er of the ceiling bracket to fit the 6 or 8 round duct work through Attach bracket to ceiling with 2 screws provided 7 Prepare duct work and electrical All Electrical work must be performed by a quali...

Страница 15: ...IN PLACE BY SCREWING SCREWS WITH WASHERS THROUGH HOOD INTO THE WALL 4HERE ARE TWO HOLES AT THE BOTTOM INSIDE THE HOOD IN WHICH TO DO THIS 0LACE TELESCOPIC DUCT COVERS ON TOP OF HOOD AND EXTEND TOP DU...

Страница 16: ...selected by presing to decrease and to increase speed level T he display indicates level selected 3 Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function...

Страница 17: ...d with non abrasive soap or in a dishwasher Filter Clean Reminder When flashes on display the baffle filters installed are required to be cleaned This will occur after every 30 hours of use Re setting...

Страница 18: ...located on the bottom of therange hood you can control the following features remotely Blower On Off By pressing the blower is switched On and Off When swi tched on the blower starts up on speed level...

Страница 19: ...CSH E42SX 36 13 16 24 5 8 1 8 CSH E36SX 31 5 16 24 5 8 1 8 Removing and Installing Insert Panel 1 Using a Phillips head screwdriver remove 3 screws a from the top cap 2 Remove top cap b and slide fron...

Страница 20: ...cleaners Baffle Filters The Metal Filters fitted by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are requiredto be kept clean...

Страница 21: ...ff and bulbs are not hot Remove bulbby pressing both ends of the metal retainingclip together the light socket will now protudefrom the hood allowingyou to remove the bulb B e careful when releasing r...

Страница 22: ...n of duct opening is against the wind 5 Using the wrong size of ducting 1 Baffle filter is loose 1 Control board needs to be reset 1 Defective control board 1 Make sure the circuit breaker and the uni...

Страница 23: ...Part Halogen Bulb GU 10 120V 50W Z0B 0020 s e i r o s s e c c A d n a s t r a P f o t s i L Internal Blower 600 cfm CBI 600 External Blower 1000 cfm CBE 1000 Duct Cover Extension Kit Z1C 00SH Accesso...

Отзывы: