background image

13

www.zephyronline.com

d.

Fasten the canopy with 11 screws from the

bottom.

Bottom

View

FRONT

FRONT

FRONT

12.

 Fix 6 nuts on the internal side of top duct covers

sections (squere slots) and fix each other with 6

screws (3 per side).

Rectangular

slots

Plan

diagram

top

sections

Nut

top

sections

Chimney

Structure

13.

Install top duct covers assembly to the chimney

structure.

Fix with 2 screws.

Note: Upper Duct Cover may be placed upside down

to hide (or unhide) ventless slots.

Inst

allation

Содержание Optica Island EOT-E42ASX

Страница 1: ...e _____________________________________ N mero de serie Date of Purchase Date d achat _____________________________________ Fecha de compra Sales Dealer D taillant ____________________________________...

Страница 2: ...eave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring...

Страница 3: ...not supplied 6 Dimensions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation 10 Electrical connection 12 Description o...

Страница 4: ...Use This Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking a...

Страница 5: ...l local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed m...

Страница 6: ...t PARTS NOT SUPPLIED Duct conduit and all tools required for installation Ductless recirculating kit to be used only in the Ductless recirculating version includes charcoal filter charcoal filter supp...

Страница 7: ...online com Dimensions and clearances 42 48 14 min 31 10 16 max 49 min 30 8 16 max 43 14 16 12 3 16 27 8 16 1 26 4 16 Ductless recirculating version ONLY Note if necessary order the proper duct cover e...

Страница 8: ...um Duct Size Ducting Ductless version 8 Round Pipe PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Fitting...

Страница 9: ...wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Rou...

Страница 10: ...ed on ceiling to position the mounting template Note location of hood front that indicated with a printed arrow side and mounting holes indicated on template Note Remember that printed arrow on templa...

Страница 11: ...x 4 screws 4 1 2 3 6 7 8 FRONT 4 For non vented recirculating installations ONLY Fix the deflector on the chimney structure 5 Note disregard this step if is intended to install a remote ventilator Pu...

Страница 12: ...ite and green according to the National Electrical Code and local codes and ordinances in 1 2 conduit from service panel to junction box J Box cover Conduit Connect black wire from service panel to bl...

Страница 13: ...e of top duct covers sections squere slots and fix each other with 6 screws 3 per side Rectangular slots Plan diagram top sections Nut top sections Chimney Structure 13 Install top duct covers assembl...

Страница 14: ...assembly rear bottom duct covers section Plan diagram top view rear bottom duct covers section snap into place 15 Fit the front bottom duct covers section and fix both sections with 8 screws each oth...

Страница 15: ...to make sure they are secure in their sockets Turn power on in service panel Check lights and blower operation per Care Use section of this manual If range hood does not operate Check that the circuit...

Страница 16: ...It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cookin...

Страница 17: ...d or in the dish washer which must be set to a low temperature and a short cycle When washed in a dish washer the grease filter may discolour slightly but this does not affect its filtering capacity T...

Страница 18: ...g area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loos...

Страница 19: ...nce misuse abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connect...

Страница 20: ...on Part halogen bulb 12V 20 W metal filter Part Description Part Ductless recirculating kit charcoal replacement filter duct cover extension kit internal blower 600 cfm in line blower 1100 cfm ZRC 00A...

Страница 21: ...21 www zephyronline com...

Страница 22: ...22...

Отзывы: