background image

8

www.zephyronline.com

Installation – 

+RRG6SHFL¿FDWLRQV

Standard

min. ducted - 27 1/2”

min. recirc - 32”

max. 42 1/2”

Z1C-01OMS

Z1C-01OMBS

min. ducted - 46 1/2”

min. recirc. - 50 1/2”

max. 80”

TOP

FRONT

SIDE

1 9

/1

6”

19 3/4”

6 7/8”

8 3/4”

12”

29 7/8”,  35 7/8”

7/8”

6”

Содержание Ombra

Страница 1: ...Use Care and Installation Guide www zephyronline com Model number Serial Number APR19 0301 Zephyr Ventilation LLC Ombra ZOM E30AS ZOM E30ABS ZOM E36AS ZOM E36ABS...

Страница 2: ...www zephyronline com...

Страница 3: ...ce 6 Ducting Options 7 RRG 6SHFL FDWLRQV 8 Mounting the Range Hood 9 Ductless Recirculating 10 FEATURES CONTROLS Capacitive Touch Controls 11 MAINTENANCE Cleaning Filter Care Lights Parts List 12 TROU...

Страница 4: ...ZDUH DQG XWHQVLOV DSSURSULDWH IRU WKH W SH RI DQG DPRXQW RI IRRG EHLQJ SUHSDUHG WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING D 6027 5 0 6 ZLWK...

Страница 5: ...Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances I FRGHV SHUPLW DQG D VHSDUDWH JURXQG ZLUH LV XVHG LW LV UHFRPPHQGHG WKDW D TXDOL HG HOHFWULFLDQ GHWHUPLQH WKDW WKH grou...

Страница 6: ...sion accessory Recirculating kit accessory HARDWARE PACKAGE CONTENTS MODELS ZOM E30AS ZOM E36AS ZOM E30ABS ZOM E36ABS PARTS SUPPLIED 1 Hood with internal blower 2 Aluminum mesh filters 1 Duct cover as...

Страница 7: ...lumn 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 r...

Страница 8: ...If available also refer to range manufacturer s height clearance requirements and recommended KRRG PRXQWLQJ KHLJKW DERYH UDQJH OZD V FKHFN RXU ORFDO FRGHV IRU DQ GL HUHQFHV XFW FRYHU H WHQVLRQ NLW DYD...

Страница 9: ...ide unless using the recirculating option 8VH VLQJOH ZDOO ULJLG 0HWDO GXFWZRUN RQO DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL HG 6LOYHU 7DSH RU XFW 7DSH Some Ducting Opt...

Страница 10: ...e com Installation RRG 6SHFL FDWLRQV Standard min ducted 27 1 2 min recirc 32 max 42 1 2 Z1C 01OMS Z1C 01OMBS min ducted 46 1 2 min recirc 50 1 2 max 80 TOP FRONT SIDE 1 9 16 19 3 4 6 7 8 8 3 4 12 29...

Страница 11: ...od HQWHU DQG DWWDFK GXFW FRYHU EUDFNHW WR ZDOO EHORZ FHLOLQJ RU VR W XVLQJ VFUHZV 8 Install electrical QVWDOO GXFW ZRUN DQG VHDO DOO MRLQWV ZLWK FHUWL HG GXFW WDSH 3RZHU XS KRRG DQG FKHFN IRU OHDNV DU...

Страница 12: ...WLRQDO FKDUFRDO OWHUV KHOS WR SXULI IXPHV H KDXVWHG IURP FRRNLQJ IRU UH FLUFXODWLRQ RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED LW LQFOXGHV FKDUFRDO OWHUV FKDUFRDO OWHU EUDFNHWV DQG DLU GLYHUWHU...

Страница 13: ...tor illuminates 390 maximum CFM If speed two indicator illuminates 290 maximum CFM 2 Fan Speed Decrease Button Press this button to decrease fan speed 4 3 2 Q Quiet If fan is off press this button to...

Страница 14: ...HHG QRW EH UHSODFHG RQ D UHJXODU EDVLV EXW DUH UHTXLUHG WR EH NHSW FOHDQ 5HPRYH DQG FOHDQ E KDQG RU LQ GLVKZDVKHU XVLQJ D QRQ SKRVSKDWH GHWHUJHQW LVFRORUDWLRQ RI WKH OWHU PD RFFXU LI XVLQJ SKRVSKDWH G...

Страница 15: ...s not secured in place KHFN WKH LQVWDOODWLRQ RI WKH KRRG The unit is whistling 7KH OWHU LV QRW LQ WKH FRUUHFW SRVLWLRQ GMXVW WKH OWHUV XQWLO WKH ZKLVWOLQJ VWRSV 2 The duct pipe connections are not sea...

Страница 16: ...ng diagram or in another clearly visible location NOTE After re positioning the jumper and powering on the hood the CFM cannot be changed again To verify if your installer enabled ACT LWK KRRG R SUHVV...

Страница 17: ...15 ZOM E30AS ZOM E30ABS ZOM E36AS ZOM E36ABS 3 3 ACT 390 CFM Fan Max 2 5A ACT 290 CFM Fan Max 2 0A 3RZHU FRQVXPSWLRQ VKRZQ IRU GHIDXOW 0 EORZHU FRQ JXUDWLRQ Wiring Diagram...

Страница 18: ...l Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOU...

Страница 19: ...nge hood at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one IT S IMPORTANT Ensures warranty co...

Отзывы: