Zephyr  Ventilation,  LLC  (referred  to  herein  as  “we”  or  “us”)  warrants  to  the  original  consumer  purchaser  (referred  to 
herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials 
or workmanship as follows:

Three Year Limited Warranty for Parts:

  For three years from the date of your original purchase of the Products, we 

will provide, free of charge, Products or parts (including LED light bulbs, if applicable) to replace those that failed due to 
manufacturing defects.  We may choose, in our sole discretion, to repair or replace parts before we elect to replace the 
Products.

One Year Limited Warranty for Labor:

  For one year from the date of your original purchase of the Products, we will 

provide, free of charge, the labor cost associated with repairing the Products or parts to replace those that failed due to 
manufacturing defects.  After the first year from the date of your original purchase, you are responsible for all labor costs 
associated with this warranty.

Warranty Exclusions: 

 This warranty covers only repair or replacement, at our option, of defective Products or parts and 

does not cover any other costs related to the Products including but not limited to: (a) normal maintenance and service 
required for the Products and consumable parts such as fluorescent, incandescent or halogen light bulbs, mesh and char-
coal filters and fuses; (b) any Products or parts which have been subject to freight damage, misuse, negligence, accident, 
faulty installation or installation contrary to recommended installation instructions, improper maintenance or repair (other 
than by us); (c) commercial use of the Products or use otherwise inconsistent with its intended purpose; (d) natural wear 
of the finish of the Products or wear caused by improper maintenance, use of corrosive and abrasive cleaning products, 
pads, and oven cleaner products; (e) chips, dents or cracks caused by abuse or misuse of the Products; (f) service trips 
to your home to teach you how to use the Products; (g) damage to the Products caused by accident, fire, floods, acts of 
God; or (h) Custom installations or alterations that impact serviceability of the Products. If you are outside our service 
area, additional charges may apply for shipping costs for warranty repair at our designated service locations and for the 
travel cost to have a service technician come to your home to repair, remove or reinstall the Products.  After the first year 
from the date of your original purchase, you are also responsible for all labor costs associated with this warranty.  

Limitations of Warranty.  OUR OBLIGATION TO REPAIR OR REPLACE, AT OUR OPTION, SHALL BE YOUR SOLE AND 
EXCLUSIVE REMEDY UNDER THIS WARRANTY.  WE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR 
SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS.  
THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS 
WARRANTIES.  WE HEREBY DISCLAIM AND EXCLUDE ALL OTHER EXPRESS WARRANTIES  FOR THE PRODUCTS, 
AND DISCLAIM AND EXCLUDE ALL WARRANTIES IMPLIED BY LAW, INCLUDING THOSE OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE.

   Some states or provinces do not allow limitations on the duration of an implied 

warranty or the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not 
apply to you.  To the extent that applicable law prohibits the exclusion of implied warranties, the duration of any applicable 
implied warranty is limited to the same two-year period described above.  Any oral or written description of the Products is for 
the sole purpose of identifying the Products and shall not be construed as an express warranty.  Prior to using, implementing 
or permitting use of the Products, you shall determine the suitability of the Products for the intended use, and you shall assume 
all risk and liability whatsoever in connection with such determination.   We reserve the right to use functionally equivalent 
refurbished or reconditioned parts or Products as warranty replacements or as part of warranty service.  This warranty is not 
transferable from the original purchaser and applies in the United States and Canada.

To Obtain Service Under Limited Warranty:  

To qualify for warranty service, you must: (a) notify us at the address or 

telephone number stated below within 60 days of the discovery of the defect; (b) give the model number and part identifi-
cation number and serial number; and (c) describe the nature of any defect in the Product or part.  At the time of the 
request  for  warranty  service,  you  must  present  evidence  of  your  proof  of  purchase  and  proof  of  the  original  purchase 
date.  If we determine that the warranty exclusions listed above apply or if you fail to provide the necessary documenta-
tion to obtain service, you will be responsible for all shipping, travel, labor and other costs related to the services.

Please check our website for any revisions, www.zephyronline.com.

Zephyr Ventilation Service Department, 2277 Harbor Bay Parkway, Alameda, CA 94502  1-888-880-8368

Limited Warranty

AUG14.0401

Proof of the original purchase 

date is needed to obtain     

service under warranty

W

arranty

Содержание Monsoon I AK9240AS

Страница 1: ...de www zephyronline com Model number Serial Number Date of Purchase Sales Dealer JUL16 0601 2016 Zephyr Ventilation LLC Monsoon I AK9228AS AK9234AS AK9240AS AK9246AS READ AND SAVE THESE INSTRUCTIONS A...

Страница 2: ...www zephyronline com...

Страница 3: ...paration Installation 10 Vertical Ducting Preparation 11 Horizontal Ducting Preparation 12 14 FEATURES CONTROLS Touch Controls 15 16 RF Remote Control 17 MAINTENANCE Cleaning and Installing Filters 18...

Страница 4: ...are and utensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING D 6027 5 0 6 ZLWK...

Страница 5: ...ational Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 This appliance requires a 120V 60Hz electric...

Страница 6: ...lar cover plate 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Light Bulb Removal Suction Cup 1 M...

Страница 7: ...0 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3...

Страница 8: ...t should be no higher than 36 It is important to install the hood at the proper mounting height Hoods mounted too low could UHVXOW LQ KHDW GDPDJH DQG UH KD DUG ZKLOH hoods mounted too high will be har...

Страница 9: ...d to the outside Use single wall rigid metal ductwork only DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV ZLWK FHUWL HG 6LOYHU 7DSH RU XFW 7DSH Some Ducting Options Installation Duc...

Страница 10: ...0 3 8 46 3 8 12 12 28 14 1 4 34 17 1 4 28 34 5 5 8 1 1 2 C L 28 34 7 3 4 3 10 3 4 22 3 8 28 3 8 34 3 8 40 3 8 19 1 4 28 9 1 4 34 12 1 4 2 9 7 8 C L 3 1 4 elec k o 5 1 2 7 3 4 40 46 5 7 8 40 20 1 4 46...

Страница 11: ...ing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere ci...

Страница 12: ...the surface you are securing the liner to is capable of holding the weight of AK92 Failure to do so may cause personal injury or damage to cooking surface or counter 5 Finalize installation of electri...

Страница 13: ...E UHPRYLQJ VFUHZV IURP EHKLQG HDFK panel Installation Vertical Ducting Preparation 1 2 1 1 2 Locking Tabs Bottom Panel Screws 2 1 4 Remove bottom panel by 1 5HPRYLQJ screws from left and right sides o...

Страница 14: ...HPRYLQJ VFUHZV IURP behind each panel 1 2 1 1 2 Locking Tabs Bottom Panel Screws 2 1 4 Remove bottom panel by 1 5HPRYLQJ screws from left and right sides of bottom panel 2 Pulling bottom panel toward...

Страница 15: ...cover plate tabs are on top of the cover plate as shown From inside the liner secure plate to WRS RI OLQHU ZLWK VFUHZV A A B C C B 8 Remove knock outs A and B for rectangular ducting Remove knock out...

Страница 16: ...XVLQJ FHUWL HG aluminum duct tape Plug in blower molex plug Horizontal ducting preparation is now complete Refer to Page 10 Step 5 to complete installation 10 Rectangular Ducting From inside the liner...

Страница 17: ...590 CFM and if number 2 displays max 390 CFM 2 Speed Selection The 6 speed levels are selected by pressing to decrease and to increase speed levels The display indicates levels selected ACT Enabled S...

Страница 18: ...eset the filter clean reminder timer after filters are cleaned and re installed With hood off press and hold for approximately 5 seconds until on display disappears The filter clean reminder function...

Страница 19: ...orage The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder FIG 4 The remote holder can be inserted into a standard electrical outlet for easy storage Not...

Страница 20: ...ntrols LOWHUV PD EH SODFHG LQ GLVKZDVKHU DW ORZ KHDW RU VRDNHG LQ KRW VRDS ZDWHU U OWHUV DQG UH LQVWDOO EHIRUH using hood QVWDOOLQJ WKH DI H LOWHUV 3ODFH OWHU LQWR WRS JURRYH RI WKH OLQHU DV VKRZQ DQG...

Страница 21: ...y turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out I EXOEV DUH GLI FXOW WR WXUQ GXH WR SURORQJHG XVH UPO DWWDFK WKH JODVV VXFWLRQ FXS SURYLGHG WR WKH E...

Страница 22: ...off press and hold the power button for three seconds If the number 6 displays defualt max CFM if the number 3 displays max 390 CFM and if the number 2 displays max 290 CFM To verify if your installe...

Страница 23: ...HZ MAX AMPS 120 60 USE ONLY TYPE MR16 GU10 35W MAX HALOGEN LIGHT BULBS CIRCUIT DIAGRAM AK9228AS AK9234AS 5 Fan Curve Wiring Diagrams ACT 390 CFM Fan Max 355W 3 0A ACT 290 CFM Fan Max 255W 2 4A AK9228A...

Страница 24: ...ssure inAq Blower Fan Curve 600 CFM Model AK92 Monsoon I AC Input 120V 60Hz Outlet Diameter 8in 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450...

Страница 25: ...23 Fan Curve Wiring Diagrams AK9240AS and AK9246AS Models Only ACT 590 CFM Fan Max 556W 4 6A ACT 390 CFM Fan Max 381W 3 4A...

Страница 26: ...24 www zephyronline com Fan Curve Wiring Diagrams AK9240AS and AK9246AS Models Only...

Страница 27: ...ed blower wheel 3 Change the blower The unit is whistling OWHU LV QRW LQ WKH FRUUHFW SRVLWLRQ GMXVW WKH OWHUV XQWLO WKH ZKLVWOLQJ VWRSV 2 The duct pipe connections are not sealed or connected properly...

Страница 28: ...N PART Replacement Parts LJKW XOE 05 8 HDFK DI H LOWHU DUJH HDFK DI H LOWHU 6PDOO HDFK RF Remote Control 14000005 To order parts visit us online at http store zephyronline com or call us at 1 888 880...