8
Milano Use, Care, and Installation Guide
M I L A N O
WA L L
C O R E
Installation Instructions
Duct pieces
Total
Equivalent number
length x used
=
3- 1/ 4” x 10”
Rect.,
straight
1 Ft.
x (
)
=
Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
5 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
90
0
elbow
20 Ft. x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
90
0
15 Ft.
x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
45
0
9 Ft. x ( ) =
Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft.
x (
)
=
Ft.
Subtotal column 1 =
Duct pieces
Total
Equivalent number
length x used
=
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) =
Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Maximum Duct Length:
For satisfactory air movement,
the total duct length
should not exceed 150 equivalent feet.
6” round to
3- 1/ 4” x 10”
rect.
transition
1 Ft. x ( ) =
Ft.
6” round to
3- 1/ 4” x 10”
rect.
transition
90
0
elbow
16 Ft. x ( ) =
Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft. x ( ) =
Ft.
7” round to
3- 1/ 4” x 10”
rect.
transition
90
0
elbow
23 Ft. x ( ) =
Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft.
x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 90
0
elbow
15 Ft.
x (
)
=
Ft.
3- 1/ 4” x 10”
Rect. 45
0
elbow
9 Ft.
x (
)
=
Ft.
3- 1/ 4” x 10”
Rect. 90
0
flat elbow
24 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) =
Ft.
Ft. x ( ) =
Ft.
15
6”, 7“, 8”
Round
in-line
damper
Ducting Calculation Sheet
Содержание Milano
Страница 2: ...2 Milano Use Care and Installation Guide MIL ANO WALL CORE...
Страница 36: ...36 Milano Use Care and Installation Guide MIL ANO WALL CORE Notes...
Страница 40: ...2 Milano Guide d utilisation d entretien et d installation MIL ANO MUR CORE...
Страница 74: ...36 Milano Guide d utilisation d entretien et d installation MIL ANO MUR CORE Remarques...