background image

21

TROUBLESHOOTING PROCEDURES

Issue

Cause

What to do

After installation, 

the unit doesn’t 

work.

1.  The power source is not turned ON.

1.  Make sure the circuit breaker and the unit’s 

power is ON.

2.  The power line and the cable locking connector 

is not connecting properly.

2.  Check the power connection with the unit is 

connected properly.

3.  The switch board or control board wirings are 

disconnected.

3.  Make sure the wirings at the switch board and 

control board are connected properly.

4.  The switch board or control board is defective.

4.  Change the switch board or control board.

Light works, but 

blower is not 

turning.

1.   The blower cable is disconnected.

1.   Connect the blower cable.

2.  Debris or obstruction in motor.

2.  Remove the debris or obstrunction.

3.  Motor defective or possibly seized.

3.  Change the blower.

4.  Damaged capacitor.

4.  Change the capacitor.

5.  The switch board or control board is defective.

5.  Change defective part.

The unit is 

vibrating.

1.  The blower is not secured in place.

1.  Tighten the blower in place.

2.  Damaged blower wheel.

2.  Replace the blower.

3.  The hood is not secured in place.

3.  Check the installation of the hood.

The blower is 

working, but the 

lights are not.

1.   The LED light strip connector is disconnected.

1.   Connect the LED light strip connector.

2.  Defective LED light strip.

2.  Change the LED light strip.

3.   The switch board or control board is defective.

3.   Change the switch board or control board.

The unit turns on 

by itself.

1.   A spot light or kitchen lamp is shining directly 

onto the switch controls.

1.   The switch controls are light sensative. A 

direct light source onto the switch controls 

may disrupt switch functions. 

The hood is 

not venting out 

properly.

1.   Using the wrong size of ducting.

1.   Change the ducting to at least 6” round or 

higher. 

2.   Using the wrong type of ducting. Flexible ducting 

can reduce air flow by up to 50%.

2.   Change the ducting to solid rigid metal 

ducting. 

3.  The hood might be hanging to high from the 

cook top.

3.  Adjust the distance between the cook top and 

the bottom of the hood within 26” and 34” 

range.

4.  The wind from the opened windows or opened 

doors in the surrounding area are affecting the 

ventilation of the hood.

4.  Close all the windows and doors to eliminate 

the outside wind flow.

5.  Blockage in the duct opening or ductwork.

5.  Remove all the blocking from the duct work or 

duct opening.

Troubleshooting

Содержание Essentials ZAN-E30CS

Страница 1: ...ephyronline com ZRO E30DS ZRO M90DS JUN17 0301 Zephyr Ventilation LLC ZRV E30BGC ZRV M90BGC ZRV E30BGG ZRV M90BGG ZRV E30BBSGG ZRV M90BBSGG ZAN E30CS ZAN E30CBS ZAN M90CS ZAN M90CBS ZSA E30DB ZSA E30D...

Страница 2: ...www zephyronline com...

Страница 3: ...7 Hood Specifications 8 11 Mounting the Hood 12 Ductless Recirculating 13 FEATURES CONTROLS ICON Touch Controls 14 15 MAINTENANCE Hood and Filter Cleaning 16 ACT CONVERSION 17 WIRING DIAGRAMS 18 FAN C...

Страница 4: ...the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie s...

Страница 5: ...ctrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code...

Страница 6: ...local codes Extension duct cover accessory Recirculating kit accessory HARDWARE PACKAGE CONTENTS PARTS SUPPLIED 1 Hood with internal blower 1 Duct cover wall bracket 1 Duct cover assembly top and bott...

Страница 7: ...lumn 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 r...

Страница 8: ...r local codes for any differences Duct cover extension kit available for ceiling heights up to 12 feet Turn to page 22 for part number and ordering information DAMAGE SHIPMENT INSTALLATION Please full...

Страница 9: ...the recirculating option Use single wall rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Installa...

Страница 10: ...Installation Hood Specification ZAN 10 3 8 1 3 16 29 15 16 35 7 16 10 5 8 22 1 16 5 5 16 4 1 1 6 STANDARD min ducted 27 min recirc 31 max 48 Z1C 00AN Z1C 00ANBS EXTENSIONS min ducted 43 min recirc 47...

Страница 11: ...1 9 1 29 15 16 35 7 16 7 1 2 19 1 2 11 STANDARD min ducted 28 min recirc 32 max 45 Z1C 01SA Z1C 01SAB Z1C 01SAW Z1C 01SABS EXTENSIONS min ducted 46 min recirc 50 max 80 1 2 Installation Hood Specifica...

Страница 12: ...ation Hood Specification ZRV STANDARD min ducted 23 min recirc 27 1 2 max 42 1 2 Z1C 00RV Z1C 00RVBS min ducted 41 min recirc 46 max 80 10 9 16 19 3 4 10 3 8 23 15 16 15 5 16 29 15 16 35 3 16 AC In 3...

Страница 13: ...tion Hood Specification ZRO CL 29 15 16 35 7 16 14 1 8 3 22 1 16 STANDARD min ducted 26 1 2 min recirc 30 1 2 max 47 1 2 Z1C 00RO EXTENSION min ducted 41 min recirc 45 max 77 11 10 5 8 6 2 3 8 2 5 8 3...

Страница 14: ...o wall just below the ceiling or soffit using 2 M6 x 1 screws 9 Install electrical and duct work Seal duct work with aluminum duct tape 10 Power up hood and check for leaks around duct tape 11 Place t...

Страница 15: ...includes charcoal filters charcoal filter brackets and air diverter plate Hood Models Part No Filters in pkg ZAN ZRC 01AN 2 ZSA ZRC 00SV 2 ZRV ZRC 00RV 2 ZRO ZRC 01RO 2 1 Purchase recirculating kit p...

Страница 16: ...ay Off Function is enabled will turn the hood off and cancel the Delay Off Function ACT Verification Airflow Control Technology ACT allows the installer to set the maximum fan CFM to align with local...

Страница 17: ...irculating hood To enable Charcoal Filter Replacement Reminder With hood off hold button and button simultaneously for two seconds All LED indicators will illuminate for three seconds confirming the C...

Страница 18: ...and buff in the direction of the stainless steel grain Cleaning Black Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth To remove heavier grease buil...

Страница 19: ...n another clearly visible location NOTE After re positioning the jumper and powering on the hood the CFM cannot be changed again To verify if your installer enabled ACT With hood off press and hold th...

Страница 20: ...18 www zephyronline com Wiring Diagrams ZAN ZSA ZRV ZRO ACT 390 CFM Fan Max 2 3A ACT 290 CFM Fan Max 1 9A Power consumption shown for default CFM blower configuration...

Страница 21: ...19 Fan Curve Diagrams ZAN ZRV ZRO ZSA...

Страница 22: ...20 www zephyronline com Fan Curve Diagrams...

Страница 23: ...cured in place 3 Check the installation of the hood The blower is working but the lights are not 1 The LED light strip connector is disconnected 1 Connect the LED light strip connector 2 Defective LED...

Страница 24: ...N BLK SS Extension Duct Cover Z1C 00ANBS ZSA Optional Accessories ZSA Recirculating Kit ZRC 00SV ZSA SS Extension Duct Cover Z1C 01SA ZSA BLK Extension Duct Cover Z1C 01SAB ZSA WHT Extension Duct Cove...

Страница 25: ...rst year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SH...

Страница 26: ...our new range hood at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one IT S IMPORTANT Ensures w...

Отзывы: