background image

Important Safety Notice

READ AND SAVE THESE INSTRUCTIONS

2

www.zephyronline.com

WARNING 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. 

WARNING 

TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

a.  Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. 
b.  Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally. 

When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.

CAUTION

For general ventilating use only. Do not use to exhaust hazardous or explosive materials  and vapors.  Take care when using cleaning
agents or detergents. Suitable for use in household cooking area. 

WARNING 

TO REDUCE THE RISK OF RANGE TOP GREASE FIRE: 

a.  Never leave surface units unattended at high settings.  Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly 

on low or medium settings. 

b.  Always turn hood ON when cooking at high heat or when flaming food
c.  Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan or filter. 
d.  Use proper pan size.  Always use cookware appropriate for the size of the surface element. 
e.  Keep fan,filters and grease laden surfaces clean. 
f.  Use high setting on hood only when necessary. 
g.  Don’t leave hood unattended when cooking. 
h.  Always use cookware and utensils appropriate for the type of and amount of food being prepared. 

WARNING 

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING: 

a.  SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. 

If the flames do not go out  immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.  

b.  NEVER PICK UP A FLAMING PAN – You may be burned.  
c.  DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d.  Use an extinguisher ONLY if:

1.  You know you have a Class ABC extinguisher, and you already know how to operate it.
2.  The fire is small and contained in the area where it started.
3.  The  fire department is being called.
4.  You can fight the fire with your back to an exit

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a.  Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. 

Including fire-rated construction.

b.  Sufficient air is needed for power combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent 

back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and
the local code authorities.

c.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d.  Ducted fans must always vent to the outdoors.
e.  If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFI 

(Ground Fault Interrupter protected branch circuit).

g.  NEVER place a switch where it can be reached from a tub or shower.
h.  Make sure the power is off before installing, wiring or maintenancing.

Содержание Brisas BMI-E36AG

Страница 1: ...Use Care and Installation Guide www zephyronline com Model number Serial Number SEP08 0101 Zephyr Corporation brisaS by Brisas BMI E36AG BMI E36AS BSI E36AS BVE E30AS BVE E36AS...

Страница 2: ...www zephyronline com...

Страница 3: ...ght Clearance 6 Ducting Options 7 Hood Speci cations 8 10 Mounting the Hood BMI BSI 11 Mounting the Hood BVE 12 Ductless Recirculating 13 FEATURES CONTROLS Touch Controls 14 MAINTENANCE Hood and Filte...

Страница 4: ...NS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not...

Страница 5: ...e with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes perm...

Страница 6: ...Duct cover extension accessory Recirculating kit accessory HARDWARE PACKAGE CONTENTS 1 Suction Cup PARTS SUPPLIED MODELS BMI E30AS BMI E30AG BSI E30AG BVE E30AS BVE E36AS 1 Hood with internal blower 1...

Страница 7: ...ent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round ro...

Страница 8: ...while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood moun...

Страница 9: ...ng option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Op...

Страница 10: ...8 www zephyronline com Installation BMI Hood Speci cations 34 26 27 21 4 9 46 4 27 4 8 9 21 6 9 2 4 5 Njo evdufe 34 Njo Sfdjs 37 203 Nby evdufe 53 7...

Страница 11: ...9 Installation BSI Hood Speci cation 3 7 8 10 3 8 25 15 16 35 7 16 15 7 16 19 3 4 7 Njo evdufe 34 Njo sfdjs 37 Nby evdufe 51 10 5 8...

Страница 12: ...10 www zephyronline com 2 2 2 9 24 27 4 8 27 3 26 27 9 22 27 9 4 5 7 8 9 23 2 4 5 5 2 4 7 4 5 46 8 9 ps Njy evdufe 38 203 Njo sfdjs 43 Nby evdufe 53 203 Installation BVE Hood Speci cation...

Страница 13: ...ver mounting bracket to wall just below the ceiling or soffit using 2 M4 x 1 screws 10 Install electrical and duct work Seal duct work with aluminum duct tape 11 Power up hood and check for leaks arou...

Страница 14: ...ectrical 9 Install duct work and duct tape 10 Power up hood and check for leaks around duct tape 11 Place telescopic duct covers onto hood and extend inner top duct cover upwards and secure to duct co...

Страница 15: ...te Hood Model Part No Filters in Pkg BMI BSI models BRC 0002 2 BVE models BRC 0001 2 1 Purchase recirculating kit per the part number above 2 Secure air diverter plate to wall below duct cover bracket...

Страница 16: ...14 www zephyronline com Features Controls Touch Controls...

Страница 17: ...n cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Metal Mesh Filters The metal mesh filters installed by the factory are intended to filter out re...

Страница 18: ...emove by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are dif cult to turn due to prolonged use firmly attach a glass suction cup approxim...

Страница 19: ...he unit is vibrating 1 The motor is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the hood...

Страница 20: ...GU 10 50W each Z0B 0020S Optional Accessories Recirculating Kit BRC 0002 for BMI BSI BRC 0001 for BVE Replacement Charcoal Filter Z0F C002 Duct Cover Extension B1C 00MI for BMI BSI B1C 00VE for BVE To...

Страница 21: ...or costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR...

Отзывы: