Zephyr AK7500BS Скачать руководство пользователя страница 2

5

Installation – 

Ducting Calculation Sheet

Duct pieces 

Total

Equivalent number
length  x used      =

3- 1/ 4” x 10”
Rect.,
straight

1 Ft.           x (      )   =

Ft.    

 

 

 

 

 

3- 1/ 4” x 10”
Rect. to
6” round
transition

5 Ft.           x (      )   =

Ft.  

 

3- 1/ 4” x 10”
Rect. to
6” round
transition
90

0  

elbow

20 Ft.         x (      )   =

Ft.  

 

6”, 7”, 8”, 10” 
Round,
90

0  

15 Ft. 

        

x (      )   =

Ft.    

6”, 7”, 8”, 10”
Round,
45

0  

9 Ft.           x (      )   =

Ft.    

Ft.    

6”, 7”, 8”, 10” 
Round,
straight 

1 Ft.           x (      )   =

Ft.   

Subtotal column 1  =

Duct pieces 

Total

Equivalent number
length  x used      =

6”, 7”, 8”, 10”
Round, wall 
cap with 
damper 

30 Ft.         x (      )   =

Ft.  

 

 

 

 

 

 

 

Ft.    

Ft.    

Ft.    

6”, 7”, 8”, 10”
Round
roof cap 

30 Ft.         x (      )   =

Ft.  

 

 

 

Subtotal column 2  =

Subtotal column 1  =

Total ductwork      =

Maximum Duct  Length: 

For satisfactory air movement,

the total duct length 

 

   

should not exceed 100 equivalent feet.

6” round to
3- 1/ 4” x 10”
rect. 
transition

1 Ft.           x (      )   =

Ft.  

 

6” round to
3- 1/ 4” x 10”
rect. 
transition
90

0  

elbow

16 Ft.         x (      )   =

Ft.  

 

7” round to
3 1/ 4” x 10”
rect. 
transition

8 Ft.           x (      )   =

Ft.  

 

7” round to
3- 1/ 4” x 10”
rect. 
transition
90

0  

elbow

23 Ft.         x (      )   =

Ft.  

 

elbow

elbow

7” to 6” or
8” to 7” Round 
tapered 
reducer

25  Ft. 

x (      )   =

Ft. 

 

3- 1/ 4” x 10”
Rect. 90

0

elbow

15 Ft.         x (      )   =

Ft.  

3- 1/ 4” x 10”
Rect. 45

0

elbow

9 Ft.           x (      )   =

Ft.  

3- 1/ 4” x 10”
Rect. 90

0

flat elbow

24 Ft.         x (      )   =

Ft. 

 

3- 1/ 4” x 10”
Rect.
wall cap
with damper

30 Ft.         x (      )   =

Ft. 

 

 Ft.         x (      )   =

Ft. 

 

15

6”, 7“, 8”
Round 
in-line 
damper

Содержание AK7500BS

Страница 1: ...Installation Guide www zephyronline com Model number Serial Number Date of Purchase Sales Dealer JUN15 0301 2015 Zephyr Ventilation LLC Tempest II AK7500BS AK7536BS AK7542BS AK7548BS READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...10 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 roundto 3 1 4 x 10 rect transition 900 elbow 16 Ft x Ft 7 roundto 3 1 4 x 10 rect transition 8 Ft x Ft 7 roundto 3 1 4 x 10 rect transition 900 elbow 23 Ft x Ft ...

Страница 3: ...tant to install the hood at the proper mounting height Hoods mounted too low could UHVXOW LQ KHDW GDPDJH DQG UH KD DUG ZKLOH KRRGV mounted too high will be hard to reach and will ORVH LWV SHUIRUPDQFH DQG HI FLHQF If available also refer range manufacturer s height clearance requirements and recommended hood mounting height above range Vertical Ducting URXQG PLQLPXP VLQJOH LQWHUQDO EORZHU URXQG PLQ...

Страница 4: ... garages All exhaust must be ducted to the outside Use metal ductwork only DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV ZLWK FHUWL HG 6LOYHU 7DSH RU XFW 7DSH Some Ducting Options Installation Ducting Options Soffit or crawl space Roof Pitch w Flashing Cap Rear Ducting Side wall cap w gravity damper ...

Страница 5: ... 4 7 7 8 or 9 15 16 R 9 16 7 7 8 or 10 3 8 1 15 16 or 4 5 16 11 9 16 10 3 4 3 3 16 7 7 8 10 3 8 9 7 8 9 1 2 14 3 16 7 7 8 or 9 15 16 Single Blower Rect Ducting Dimension Single Blower Round Ducting Dimension Dual Blower Dimension 1 11 16 29 7 8 30 35 7 8 36 41 7 8 42 47 7 8 48 C L C L Back View Mounting Dimensions 16 7 8 16 1 8 13 5 8 1 11 16 3 5 16 21 1 4 27 3 8 36 42 35 1 4 48 5 5 16 ...

Страница 6: ...ing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product Cable Lock FDEOH ORFNLQJ FRQQHFWRU QRW VXSSOLHG PLJKW DOVR EH UHTXLUHG E ORFDO F...

Страница 7: ... 4 AK7548BS 45 x 1 2 x 4 6 Prepare duct pipe and duct cut outs in upper cabinet if needed or ZDOO I KRUL RQWDOO GXFWLQJ KRRG 5HIHU WR KRRG VSHFL FDWLRQV RQ page 8 for dimensions 7 Prepare electrical wiring and electrical cut outs in upper cabinet if needed or wall if horizontal electrical hook up is required Refer to KRRG VSHFL FDWLRQV RQ SDJH IRU GLPHQVLRQV 0RXQW KRRG RQWR ZRRG ERDUG DQG VHFXUH X...

Страница 8: ...h round rear ducting C This range hood is equipped standard with a 8 round vertical duct option To convert from 8 round vertical to 8 round horizontal ducting or 3 1 4 x 10 rectangular horizontal ducting please following the instructions below VERTICAL TO HORIZONTAL DUCTING CONVERSION Installation Single Blower Horizontal Ducting Conversion B 5HPRYH VFUHZV DWWDFKLQJ EORZHU WR EORZHU plate Turn blo...

Страница 9: ...top of hood body From outside hood body attach top cover plate to top of hood body using VFUHZV 8 Connect blower plug Installation Single Blower Horizontal Ducting Conversion 5 Position single blower with single blower plate as shown Be sure to tuck back of single blower plate into tabs at back of hood Secure single EORZHU SODWH WR EDFN RI KRRG XVLQJ VFUHZV removed from step 2 ...

Страница 10: ...step 3 This range hood is equipped standard with a single blower vertical duct option To convert from single blower vertical ducting to dual blower vertical ducting please following the instructions below 5 Position dual blower inside hood body as shown Be sure to tuck dual blower plate into EORZHU SODWH WDEV 6HFXUH GXDO EORZHU E screws previously removed from step 2 6 Attach 10 round blower colla...

Страница 11: ...tisde hood body attach top cover plate to top of hood body using VFUHZV 8 Attach 10 inch round blower collar to back of KRRG XVLQJ 0 VFUHZV RQQHFW EORZHU wire extension cable to new blower and connect both plugs from each blower to female plugs behind switch panel A Installation PBD 1200A Dual Blower Horizontal Ducting Follow Steps 1 through 4 on page 13 then continue PBD 1200A horiztantal ducting...

Отзывы: