26
Luce Use, Care, and Installation Guide
L U C E
WA L L
C O R E
Troubleshooting
The hood is not venting
out properly.
Using the wrong size of ducting.
Change the ducting to the correct size.
The hood might be hanging to high
from the cook top.
Adjust the distance between the cook top
and the bottom of the hood within 24” and
34” range.
The wind from the opened windows
or opened doors in the surrounding
area are affecting the ventilation of
the hood.
Close all the windows and doors to eliminate
the outside wind flow.
Blockage in the duct opening or
ductwork.
Remove all the blocking from the duct work
or duct opening.
The unit turns on by
itself.
Remote control may be paired
incorrectly.
Resynchronize the remote control to
connect to a different channel
Filter is vibrating.
Filter is loose.
Adjust or change the filter.
Spring clip is broken on the filter.
Change the spring clip.
RF Remote control does
not work.
Battery is dead.
Replace battery with type A23 12v.
Poor communication with the hood.
Remote control must be within 15 ft of hood.
RF Remote lost communication with
the hood.
Reset hood and remote by switching power
off at the circuit breaker for 5 minutes.
Place remote on counter top near the hood
and switch the circuit breaker back on.
Blue antenna wire is not extended.
Extend the blue antenna wire behind the
light panel.
Possible Problem
Possible Cause
Solutions
Содержание ACT Luce ZLU-E30CS
Страница 2: ...2 Luce Use Care and Installation Guide LUCE WALL CORE...
Страница 28: ...28 Luce Use Care and Installation Guide LUCE WALL CORE Notes...
Страница 32: ...2 Luce Guide d utilisation d entretien et d installation LUCE MUR CORE...
Страница 58: ...28 Luce Guide d utilisation d entretien et d installation LUCE MUR CORE Remarques...