Luce

ZLU-E30CS, ZLU-M90CS
EN   Use, Care, and Installation Guide 

FR   Guide d’utilisation, d’entretien et d’installation

Содержание ACT Luce ZLU-E30CS

Страница 1: ...WWW ZEPHYRONLINE COM APR22 0101 Airflow Control Technology TM C Luce ZLU E30CS ZLU M90CS EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Страница 2: ...2 Luce Use Care and Installation Guide LUCE WALL CORE...

Страница 3: ...ght Clearance Ducting 9 10 Ducting Options 11 Hood Specifications 12 Electrical Supply 13 Cable Lock 13 Mounting the Hood 14 Ductless Recirculation 15 Recirculating Kit Installation 15 Features Contro...

Страница 4: ...securely fasten a prominent warning device such as a tag to the service panel General Safety WARNING Warning means that failure to heed this safety statement may result in extensive product damage se...

Страница 5: ...hin walls ceilings attics crawl spaces or garages WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be...

Страница 6: ...ected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire with ground Please also refer to Electrical Diagram on p...

Страница 7: ...on duct covers Z1C 00LU Optional remote control RC 0002 Optional RF remote control 14000005 Optional recirculating kit ZRC 00LU Parts Supplied Quantity Part 1 Hood with internal blower 2 Duct covers 1...

Страница 8: ...t 6 7 8 10 Round roof cap 30 Ft x Ft Subtotal column2 Subtotal column1 Total ductwork Maximum Duct Length For satisfactory air movement the totalductlengthshould not exceed 150 equivalent feet 6 round...

Страница 9: ...Ducting 24 min 34 max min A min B max C min D min E max F Standard Extension Hood Heights Duct Cover Duct Cover min ducted A 26 1 2 41 1 2 min recirculating B 31 45 1 2 max C 50 80 Ceiling Heights min...

Страница 10: ...s than 24 Maximum mount height should be no higher than 34 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoo...

Страница 11: ...tape all joints w certified Silver Tape or Duct Tape Fire Hazard NEVER exhaust air or terminate ductwork into spaces between walls crawl spaces ceilings attics or garages All exhaust must be ducted to...

Страница 12: ...Installation Instructions Hood Specifications 4 6 C L 30 29 15 16 36 35 7 16 10 3 8 2 1 16 22 STANDARD min ducted 26 1 2 min recirc 31 max 50 Z1C 00LU EXTENSION min ducted 41 1 2 min recirc 45 1 2 ma...

Страница 13: ...d or adapter plug with this appliance Follow national electrical codes or prevailing local codes and ordinances This appliance requires a 120V 60Hz electrical supply and connected to an individual pro...

Страница 14: ...ket to hood Reposition electronics mounting bracket as shown in FIG C and secure to motor housing using 2 pre installed screws FIG C3 5 Remove the 2 aluminum mesh filters 6 Hang hood onto the mounting...

Страница 15: ...below The standard mesh filters are intended to capture residue from cooking and the optional charcoal filters help to purify fumes exhausted from cooking for recirculation Recirculating Kit Installa...

Страница 16: ...essing Button while Delay Off Function is enabled will turn the hood off and cancel the Delay Off Function ACT Verification Airflow Control Technology ACT allows the installer to set the maximum fan C...

Страница 17: ...button simultaneously for two seconds All LED indicators will illuminate for three seconds confirming the Charcoal Filter Replace Reminder is enabled To disable Charcoal Filter Replacement Reminder W...

Страница 18: ...nnect the red wiring from the remote control control board to red connector in hood PC board 4 Adhere remote control control board near PC board box 5 The blue antenna wire needs to be extended for op...

Страница 19: ...or easy storage Note The remote holder does not charge the RF remote Maximum remote control communication distance is 15 feet from the liner RF Remote Maintenance Clean the remote control using non ab...

Страница 20: ...of the stainless steel grain To remove heavier grease build up use a liquid degreaser detergent After cleaning use a non abrasive stainless steel polish cleaners to polish and buff out the stainless l...

Страница 21: ...likely event that your LumiLight LED fails please contact Zephyr to order replacement parts See the list of parts and accessories page for part numbers and contact information LED Removal FIG H 1 Remo...

Страница 22: ...er to easily set the maximum blower speed to one of two most commonly specified CFM levels 390 or 290 CFM The usage of ACT may not be necessary for your installation Please check your local codes for...

Страница 23: ...r enabled ACT 1 With hood off hold the power button for three seconds If 5 LEDs illuminate default max If 4 LEDs illuminate max 390 CFM and if 3 LEDS illuminate max 290 CFM 2 When ACT is enabled the n...

Страница 24: ...s Hz Max Amps 120 60 4 REMARKS CAPACITOR 12 5 12 5uF 250VAC FIT AC120V 60Hz Motor Green Body Red Yellow Blue Brown Grey White Yellow Red Control PC Body Green Black White LED LED Yellow Black White Po...

Страница 25: ...ged into the molex connector The thermally protected system detects if the blower is too hot to operate and shuts the blower down The blower will function properly after the thermally protected system...

Страница 26: ...duct work or duct opening The unit turns on by itself Remote control may be paired incorrectly Resynchronize the remote control to connect to a different channel Filter is vibrating Filter is loose Ad...

Страница 27: ...nt Parts LumiLight LED 6W Z0B0047 Aluminum Mesh Filter each 50200053 Charcoal Filter each Z0F C092 Optional Accessories Make up Air Kit MUA006A Remote Control Kit RC 0002 RF Remote Control 14000005 Du...

Страница 28: ...28 Luce Use Care and Installation Guide LUCE WALL CORE Notes...

Страница 29: ...o be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIAB...

Страница 30: ...nt to register your new Zephyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one IT S...

Страница 31: ...WWW ZEPHYRONLINE COM APR22 0101 Airflow Control Technology TM C Luce ZLU E30CS ZLU M90CS EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Страница 32: ...2 Luce Guide d utilisation d entretien et d installation LUCE MUR CORE...

Страница 33: ...gagement et gaine 9 10 Options de conduits 11 Sp cifications de la hotte 12 Fourniture lectrique 13 Raccord de c ble 13 Montage de la hotte 14 Recirculation sans conduit 15 Installation du kit de reci...

Страница 34: ...t l entretien ou le nettoyage de l unit coupez l alimentation au panneau de service et verrouillez les moyens de d connexion de service pour viter toute mise sous tension accidentelle Lorsque le moyen...

Страница 35: ...ormes applicables y compris la construction r sistant au feu b Une quantit d air suffisante est n cessaire pour une combustion et une vacuation correctes des gaz par le conduit de fum e chemin e de l...

Страница 36: ...imentation lectrique de 120 V 60 Hz et est connect un circuit de d rivation individuel correctement mis la terre prot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blage doit tr...

Страница 37: ...uit d extension Z1C 00LU T l commande en option RC 0002 T l commande RF en option 14000005 Kit de recirculation en option ZRC 00LU Pi ces fournies Quantit Partie 1 Hotte avec ventilateur interne 2 Cac...

Страница 38: ...ilis rect droit circ droit rect coude 90 rect coude 45 rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air convenable la long...

Страница 39: ...min B max C min D min E max F Couverture de Couverture de Hood Heights conduit standard conduit d extension min ducted A 26 1 2 po 41 1 2 po min recirc B 31 po 45 1 2 po max C 50 po 80 po Hauteurs de...

Страница 40: ...a hotte ne doit pas tre inf rieure 24 po La hauteur de montage maximale ne doit pas d passer 34 po Il est important d installer la hotte la bonne hauteur de montage Les hottes mont es trop bas peuvent...

Страница 41: ...u du ruban adh sif Risque d incendie NE JAMAIS vacuer l air ni terminer de conduits dans des espaces entre les murs les vides sanitaires les plafonds les greniers ou les garages Tout l chappement doit...

Страница 42: ...n Sp cifications de la hotte 4 po 6 po C L 30 po 29 15 16 po 36 po 35 7 16 po 10 3 8 po 2 1 16 po 22 po LA NORME min canalis 26 1 2 po min recirc 31 po max 50 po Z1C 00LU EXTENSION min canalis 41 1 2...

Страница 43: ...tion individuel correctement mis la terre prot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blage doit tre 2 fils avec terre Veuillez galement vous r f rer au sch ma lectrique...

Страница 44: ...pport de montage de l lectronique comme illustr la FIG C et fixez le au bo tier du moteur l aide de 2 vis pr install es FIG C3 5 Retirez les 2 filtres mailles en aluminium 6 Accrochez la hotte aux vis...

Страница 45: ...es standard sont destin s capturer les r sidus de cuisson et les filtres charbon en option aident purifier les fum es vacu es de la cuisson pour la recirculation Installation du kit de recirculation n...

Страница 46: ...d arr t retardement est en cours d utilisation pour teindre la hotte et annuler la fonction d arr t retardement V rification de la ACT La technologie de contr le du d bit d air permet l installeur d a...

Страница 47: ...fonc es simultan ment pendant deux secondes Tous les indicateurs DEL s illuminent pendant trois secondes confirmant l activation du rappel de remplacement des filtres charbon Pour d sactiver le rappel...

Страница 48: ...tance au connecteur rouge de la carte de circuits imprim s de la hotte 4 Collez la carte de contr le distance pr s du bo tier de la carte PC 5 Le fil d antenne bleu doit tre rallong pour un signal opt...

Страница 49: ...gement facile Remarque Le support de t l commande ne charge pas la t l commande RF La distance de communication maximale de la t l commande est de 15 pieds de la doublure T l maintenance RF Nettoyez l...

Страница 50: ...dable Pour liminer les accumulations de graisse plus lourdes utilisez un d tergent d graissant liquide Apr s le nettoyage utilisez un produit de polissage nettoyant pour acier inoxydable non abrasif p...

Страница 51: ...berait en panne veuillez contacter Zephyr pour commander des pi ces de rechange Voir la page de la liste des pi ces et accessoires pour les num ros de pi ces et les coordonn es Retrait de la LED FIG H...

Страница 52: ...r de r gler facilement la vitesse maximale du ventilateur sur l un des deux niveaux CFM les plus couramment sp cifi s 390 ou 290 PCM L utilisation d ACT peut ne pas tre n cessaire pour votre installat...

Страница 53: ...le capot teint maintenez le bouton d alimentation enfonc pendant trois secondes Si 5 LED s allument d faut max Si 4 LED s allument max 390 CFM et si 3 LED s allument max 290 PCM 2 Lorsque ACT est acti...

Страница 54: ...60 4 REMARQUES CONDENSATEUR 12 5 12 5uF 250VAC FIT AC120V 60Hz Moteur Corps Vert Rouge Jaune Bleu Marron Gris Blanc Jaune Rouge Contr ler PC Corps Vert Noir Blanc LED LED Jaune Noir Blanc Consommatio...

Страница 55: ...r molex Le syst me thermiquement prot g d tecte si le ventilateur est trop chaud pour fonctionner et arr te le ventilateur Le ventilateur fonctionnera correctement apr s le refroidissement du syst me...

Страница 56: ...ure du conduit L unit s allume d elle m me La t l commande n est peut tre pas coupl e correctement Resynchronisez la t l commande pour vous connecter un autre canal Le filtre vibre Le filtre est l che...

Страница 57: ...LumiLight LED 6 W Z0B0047 Filtre mailles en aluminium chacun 50200053 Filtre charbon chacun Z0F C092 Accessoires optionnels Kit d air d appoint MUA006A Trousse de t l commande RC 0002 T l commande RF...

Страница 58: ...28 Luce Guide d utilisation d entretien et d installation LUCE MUR CORE Remarques...

Страница 59: ...de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE RECOURS SOUS LA PR SENTE GARANTI...

Страница 60: ...www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il assure la couverture de...

Отзывы: