Zephyr Essentials Milano Wall Скачать руководство пользователя страница 2

5

Duct pieces 

Total

Equivalent number
length  x used      =

3- 1/ 4” x 10”
Rect.,
straight

1 Ft.           x (      )   =

Ft.    

 

 

 

 

 

3- 1/ 4” x 10”
Rect. to
6” round
transition

5 Ft.           x (      )   =

Ft.  

 

3- 1/ 4” x 10”
Rect. to
6” round
transition
90

0  

elbow

20 Ft.         x (      )   =

Ft.  

 

6”, 7”, 8”, 10” 
Round,
90

0  

15 Ft. 

        

x (      )   =

Ft.    

6”, 7”, 8”, 10”
Round,
45

0  

9 Ft.           x (      )   =

Ft.    

Ft.    

6”, 7”, 8”, 10” 
Round,
straight 

1 Ft.           x (      )   =

Ft.   

Subtotal column 1  =

Duct pieces 

Total

Equivalent number
length  x used      =

6”, 7”, 8”, 10”
Round, wall 
cap with 
damper 

30 Ft.         x (      )   =

Ft.  

 

 

 

 

 

 

 

Ft.    

Ft.    

Ft.    

6”, 7”, 8”, 10”
Round
roof cap 

30 Ft.         x (      )   =

Ft.  

 

 

 

Subtotal column 2  =

Subtotal column 1  =

Total ductwork      =

Maximum Duct  Length: 

For satisfactory air movement,

the total duct length 

 

   

should not exceed 100 equivalent feet.

6” round to
3- 1/ 4” x 10”
rect. 
transition

1 Ft.           x (      )   =

Ft.  

 

6” round to
3- 1/ 4” x 10”
rect. 
transition
90

0  

elbow

16 Ft.         x (      )   =

Ft.  

 

7” round to
3 1/ 4” x 10”
rect. 
transition

8 Ft.           x (      )   =

Ft.  

 

7” round to
3- 1/ 4” x 10”
rect. 
transition
90

0  

elbow

23 Ft.         x (      )   =

Ft.  

 

elbow

elbow

7” to 6” or
8” to 7” Round 
tapered 
reducer

25  Ft. 

x (      )   =

Ft. 

 

3- 1/ 4” x 10”
Rect. 90

0

elbow

15 Ft.         x (      )   =

Ft.  

3- 1/ 4” x 10”
Rect. 45

0

elbow

9 Ft.           x (      )   =

Ft.  

3- 1/ 4” x 10”
Rect. 90

0

flat elbow

24 Ft.         x (      )   =

Ft. 

 

3- 1/ 4” x 10”
Rect.
wall cap
with damper

30 Ft.         x (      )   =

Ft. 

 

 Ft.         x (      )   =

Ft. 

 

15

6”, 7“, 8”
Round 
in-line 
damper

Installation – 

Ducting Calculation Sheet

Содержание Milano Wall

Страница 1: ...tallation Guide www zephyronline com Model number Serial Number AUG15 0801 Zephyr Ventilation LLC For use with models of serial numbers beginning with 24 Air ow Control Technology TM C Milano Wall ZMI...

Страница 2: ...lumn 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 r...

Страница 3: ...LWV SHUIRUPDQFH DQG HI FLHQF If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any diffe...

Страница 4: ...ing option Use single wall rigid Metal ductwork only DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL HG 6LOYHU 7DSH RU XFW 7DSH Some Ducting Options Installation Ducting Opti...

Страница 5: ...RRG 6SHFL FDWLRQV side of hood front of hood top of hood STANDARD min ducted 26 1 2 min recirc 31 max 50 Z1C 01MI min ducted 42 min recirc 46 max 80 13 5 8 20 1 2 12 13 16 23 15 16 6 3 8 18 1 16 8 3...

Страница 6: ...QJ RU VRI W XVLQJ 0 VFUHZV 11 Install electrical and duct work Seal duct work with aluminum duct tape Re install electrical junction box with cable lock and LQVWDOO WKH HOHFWULFDO 12 Power up hood and...

Страница 7: ...UIRED IF NO DUCTING IS USED LW LQFOXGHV FKDUFRDO OWHUV DQG DLU GLYHUWHU SODWH Hood Model Part No Filters in Pkg ZMI M90BG BS ZRC 00MI 2 1 Purchase recirculating kit per the part number above 6HFXUH DL...

Отзывы: