1-888-610-2818
11
zenty.com
No. Name
Description
2
RS232 ports
Left (DEBUG):
Pins TX, RX, G are used for
device troubleshooting only.
RS232 parameters:
Baud Rate
115 200 bps
Data Bits
8 bits
Parity
None
Stop Bits
1
Middle (Control):
Pins G, RX, TX are used for
controlling, configuring and managing IP
controller, encoders and decoders through
RS232 software or a third party controller.
RS232 parameters:
Baud Rate
9 600 bps
Data Bits
8 bits
Parity
None
Stop Bits
1
Right (Power):
Pins G, 12V are used for
providing a 12 VDC 0.5 A output.
Note:
Please connect the correct pins for
device debug and control. When IP controller
is powered by a power adapter, if you connect
control terminal to control port after first
connection with the debug port, you need to
reboot IP controller for device control process.
3
DC 12V
Connects to a supplied 12 VDC 1 A power
adapter.