Example: Apply EDID profile “Default 1” to HDMI Input 

Operation

 

 

Select “EDID” in the main menu and press the “ENTER” butto

 

Press the “Up and Down” buttons to select “Input 1”

 

 Press the "ENTER" button to enter the next sub-menu 

 

Press the “Up and

 

Down” buttons to select “Default1” and press “ENTER” to appl

the EDID profile 

 EDID Profile settings (max resolution | audio format | HDR) will be shown when the 

EDID profile is highlighted.

 

Содержание ZT-114

Страница 1: ...844 200 1945 sales zenty com Page 1 of 35 Copyright Zenty AV Zenty Professional A V Solution Provider ZENTY 9807 EMILY LANE STAFFORD TX 77477 844 200 1945 SUPPORT ZENTY COM...

Страница 2: ...844 200 1945 sales zenty com Page 2 of 35 Copyright Zenty AV...

Страница 3: ...844 200 1945 sales zenty com Page 3 of 35 Copyright Zenty AV...

Страница 4: ...built in EDID EDID copy function for maximum compatibility with different devices 4 x HDMI Inputs 4 x HDMI Outputs 4 x Coaxial SPDIF Audio Out 4 x Analog Audio Out HDMI 2 0 HDCP 1 4 2 2 Compliant Ban...

Страница 5: ...2 HDMI Standard 1 4 2 0 Audio Format Supported PCM 2 0 Dolby TrueHD DTS HD Master Audio LPCM 7 1 RS232 Serial Port 3 Pin Phoenix Connector Ethernet Port IP Control RJ45 Female IR Ext Port 3 5mm TRS Fe...

Страница 6: ...844 200 1945 sales zenty com Page 6 of 35 Copyright Zenty AV...

Страница 7: ...s input ports via HDMI cable Connect HDMI from matrix s output ports to displays Optional Connect RS232 cable from PC to RS232 port on the matrix Optional Connect an Ethernet cable from the TCP IP por...

Страница 8: ...844 200 1945 sales zenty com Page 8 of 35 Copyright Zenty AV...

Страница 9: ...1 audio Lock Remote Control Short press W to lock remote buttons Short press again to unlock Turn Off Output Port Output X ex Output1 X disables Output 1 Port Output X again to enable Output Port Cyc...

Страница 10: ...4 to All Outputs Operation Press ALL Long Press Input 4 There are 2 sub menus in the video menu Switching On Off Operation Select Video in the main menu press ENTER b u t t o n Press Up and Down butto...

Страница 11: ...945 sales zenty com Page 11 of 35 Copyright Zenty AV Press the Up and Down buttons to select the de sired input Your current selection will be highlighted in white Press ENTER button to complete video...

Страница 12: ...led by default Operation In the main menu select Video and press ENTER button Press Up and Down buttons to select On Off Press ENTER button to enter the next sub menu Press Up and Down buttons to sele...

Страница 13: ...844 200 1945 sales zenty com Page 13 of 35 Copyright Zenty AV There are 2 sub menus in Audio Control menu Line Out De Embed...

Страница 14: ...e audio of TV connected to HDMI Output 1 Operation Audio ENTER Line Out Output1 Off ENTER De Embed function allows users to enable or disable Analog and Digital Audio Output ports Operation Select Aud...

Страница 15: ...in the main menu and press the ENTER button Press the Up and Down buttons to select Input 1 Press the ENTER button to enter the next sub menu Press the Up and Down buttons to select Default1 and press...

Страница 16: ...A supports 8 presets that can be set via web GUI RS232 commands or front panel buttons Preset Control Interface has three sub menus Call Scene Save Scene Clear Scene Operation Select Preset in the mai...

Страница 17: ...f 35 Copyright Zenty AV Clear Preset Select Clear Highlight any of the previously saved Presets Preset 1 through 8 ENTER The Setup interface allows users to set serial port baud rate enable DHCP reboo...

Страница 18: ...0 57600 115200 default Example Setting Baud Rate to 9600 Operation Select Setup in the main menu and press the ENTER button Press the Up and Down buttons to select Baud Press ENTER to enter the next s...

Страница 19: ...and Down buttons to select DHCP setting Press ENTER to enter the next sub menu Press Up and Down buttons to select On Press ENTER to enable DHCP to allocate IP address automatically Select Setup in ma...

Страница 20: ...tting IP address can t be reset with the Factory Common reset 2 Factory All Factory reset for AV routing EDID audio line out and de embed settings device settings presets and device name Example Facto...

Страница 21: ...System Information System Interface Query company name device name and version information IP Interface Query device IP address MAC address and DHCP status Operation Select INFO in the main menu and...

Страница 22: ...844 200 1945 sales zenty com Page 22 of 35 Copyright Zenty AV Press ENTER to enter the next sub menu here system or IP information is available...

Страница 23: ...844 200 1945 sales zenty com Page 23 of 35 Copyright Zenty AV Choose correct COM port that connects to the PC in the parameter configuration area...

Страница 24: ...ce through the web GUI it is necessary to configure the IP address of the computer connected to the JTECH 4KM44A to ensure that the computer and the device are set in the same network segment 1 Open N...

Страница 25: ...address of the matrix 192 168 1 168 in your browser s address bar Type in user name and password default user name admin default password 123456 Note We recommend to using the latest version of Googl...

Страница 26: ...rt 4 Store Preset 1 Preset 8 Recall recall the preset Save save the preset Operation steps 1 Call Preset Preset1 Recall recall Preset 1 2 Save Preset Preset2 Recall save Preset 2 Modify Port Name 1 S...

Страница 27: ...ick Output 1 4 HDMI Enable Disable HDMI Output Audio Ex Disable HDMI Output 1 Audio Operation Click Output 1 HDMI button Button color will change and audio will be disabled Press again to enable audio...

Страница 28: ...1 Operation Click Output 1 De Embed button Button color will change and audio de embed ports will be disabled Press again to enable de embed audio ports 1 Input 00 Input1 00 16 EDID number Input 1 4 H...

Страница 29: ...o channels HDR and serial number 2 Edit User EDID Click Edit User EDID Choose EDID profile from the drop down menu on EDID Edit Page and then save to User 1 4 profiles Operation 1 Apply Default2 EDID...

Страница 30: ...pply button to apply changes If device IP address is the same as client IP the user will need to re login to the web GUI Dynamic IP Click DHCP switch DHCP On IP address will be assigned by router and...

Страница 31: ...ot clear user parameters Factory Common Click to reset device to partial factory settings Will not clear network and preset parameters Factory All Click to reset device to full factory settings 2 Chan...

Страница 32: ...using the USB micro port Both MCU and GUI are upgradeable via USB Ff firmware is encrypted decrypt before updating Connect unit to PC via USB cable from micro USB port Open Application UART_ISP_V1 6...

Страница 33: ...3 of 35 Copyright Zenty AV Connect unit to PC via USB cable from micro USB port Open Application UART_ISP_V1 6 exe and select correct USB COM port Set Baud Rate 115200 Type in F0 in PORT Select PATH a...

Страница 34: ...ling the complaint and provide a day time phone and or email address where you can be reached This Limited Warranty ONLY COVERS failures due to defects in material or workmanship and DOES NOT COVER no...

Страница 35: ...844 200 1945 sales zenty com Page 35 of 35 Copyright Zenty AV WWW ZENTY COM 9807 EMILY LANE STAFFORD TX 77477 844 200 1945 SUPPORT ZENTY COM SALES ZENTY COM...

Отзывы: