background image

 

 
 

 

 

  

Zentox Pure Air

 

by Photox™

 

 

Operations and Maintenance 

Manual 

 

for 

 

Model 

500

 

 

Advanced Indoor Air Purification 

System 

 
 
 

Please read and follow all instructions prior to operation 

of the unit. 

 

 

 

 

Содержание Photox 500

Страница 1: ...1 Zentox Pure Air by Photox Operations and Maintenance Manual for Model 500 Advanced Indoor Air Purification System Please read and follow all instructions prior to operation of the unit...

Страница 2: ...2 This Page Intentionally Blank...

Страница 3: ...VI UNSCHEDULED MAINTENANCE 20 VII REPLACEMENT PARTS LIST 21 VIII WARRANTY 22 IX SERVICE RECORD 24 Zentox Corporation cannot be held responsible for any accidents or injuries as a result of misuse or...

Страница 4: ...Pure Air purification system is manufactured by Zentox Corporation in Virginia The Photox unit is covered by U S Patents No 5 766 455 and No 5 834 069 Canadian Patents No 2253706 and No 2253707 as we...

Страница 5: ...lass fiber media coated with the catalyst to oxidize VOC s The design is such that all air passes through the CRM s with no undesirable short circuiting or by passing of the catalytic surfaces The CRM...

Страница 6: ...QUIREMENTS 110 120 volts AC 60 Hz AIR MOVEMENT Approximately 500 cfm high speed IV OPERATION A Remove the unit from its packing box Insure all packing materials are removed from the louvers to insure...

Страница 7: ...sition This will turn the unit on and will turn on the lamps and the fan to its maximum speed There should be air movement through the unit The unit has a variable speed fan which can be used to reduc...

Страница 8: ...RM is not consumed during operation it will become fouled with dust that will interfere with airflow and the unit s efficiency In environments where the air is heavily laden with dust the CRM should b...

Страница 9: ...f lamp If a lamp picks up fingerprints or other smudges wipe off thoroughly with glass cleaner and a clean cloth before operating the unit Failure to keep lamps clean of fingerprints or smudges will s...

Страница 10: ...before servicing Avant de debrancher le service This Unit contains Ultraviolet Lights Avoid UV exposure to eyes or skin Eviter l exposition aux UV pour les yeux ou la peau CAUTION ATTENTION CAUTION A...

Страница 11: ...11 Figure 1 Screw Removal 2 Open the cabinet by lifting lid and allow it to rest on its hinge in an upright position See Figure 2...

Страница 12: ...2 Opening Lid CAUTION Unit is top heavy when lid is open for service B Removing the CRMs 1 After opening the cabinet remove all 4 CRM s by sliding modules upward and out of their retaining sleeves See...

Страница 13: ...event injury from falling lid The CRMs cannot be cleaned and re used The CRMs should be installed so the indicator arrow on the CRM points towards the UV lamps Improper installation will reduce the op...

Страница 14: ...tive use of a maximum of 8 000 hours C Removing the UV Lamps 1 Lift the Light Shield out and set it aside see Fig 4 Figure 4 Removing the Light Shield 2 Disconnect one lamp from lamp support by gently...

Страница 15: ...15 Figure 5 Disconnecting Lamp from Lamp Support 3 Press the button on the Lamp Base The UV lamp will spring forward and allow the UV lamp to be lifted out see Figure 6...

Страница 16: ...ESS Figure 6 Lamp Removal 4 Repeat steps 2 and 3 for all 4 lamps before installing any new UV Lamps NOTE UV lamps may be disposed of in a similar manner as fluorescent lamps D Installing new UV Lamps...

Страница 17: ...of lamp If lamp picks up fingerprints or other smudges wipe off thoroughly with glass cleaner and a clean cloth before operating the unit Failure to keep the lamp clean of fingerprints or smudges will...

Страница 18: ...pins on the end of the lamp into the slots in the lamp socket see first image Figure 8 4 While holding the lamp GENTLY slide the lamp backwards until you feel the spring loaded latch catch see second...

Страница 19: ...ight Shield Installation WARNING Improper installation of light shield can cause exposure to harmful Ultra violet light The light shield must be returned to its proper P position before operation of t...

Страница 20: ...s receptacle located near the power cord at the rear bottom of unit Fuse 5 amp Fusible 5 Amperes Relamp with MAX 36 watt TYPE PL L 36W TUV Use only 125 250 Volt Fuse 5 Amp Max Air quality benefits wil...

Страница 21: ...ng information VII REPLACEMENT PARTS PART ZENTOX PART NUMBER UV Lamp 40 1101 101 Catalytic Reaction Module CRM 40 4001 101 Service Kit Includes 4 UV Lamps and 4 CRM s 40 1201 101 Zentox Corporation 60...

Страница 22: ...n examination of the Equipment Zentox determines that the alleged defect constitutes a substantial defect and ii the Warranty made herein is not invalid pursuant to Section C hereof The Customer agree...

Страница 23: ...r than scheduled maintenance per Zentox written instructions shall be deemed unauthorized unless it is made i by Zentox or a duly authorized agent of Zentox or ii with the prior written consent of Zen...

Страница 24: ...5 07 IX SERVICE RECORD Date of Start Up _____________ Service Dates Lamp CRM Date Hour Meter Reading ___ ___ ______ __________ ___ ___ ______ __________ ___ ___ ______ __________ ___ ___ ______ ______...

Страница 25: ...25...

Отзывы: