21
Tool Calibration
If a repair replacement motor or drive plate is required, the pruners need to be recalibrated.
Calibration Steps
1) Remove the upper and lower blades.
2) Insert the battery.
3) Hold down the trigger and remain motionless. Press the POWER switch again.
4) The trigger remains motionless for more than 20 seconds.
5) Release the trigger when you hear the motor turning.
6) The electric motor rotates during calibration. When the motor stops turning the
calibration is complete.
11.
Screw the M5 hexagon
socket countersunk head
counterclockwise as shown.
12.
Reduce the friction between the
two blade planes by adding oil as
shown in the figure.