background image

 

 

 

Securel

 

http://www.zennio.com

 

            

Technical Support:

 

http://support.zennio.com

 

 

8

 

3

 

LED NOTIFICATION 

The programming LED will notify the 

programming mode

, the 

pairing mode

 and the 

lock status

If the device is not paired, it will be in 

pairing mode

 and this will be notified by a 

blue 

flicker

.  

On the other hand, if the device is paired, the relay status will be notified with 

the LED 

green lighted if the relay is closed 

(door opened). The LED 

turn off when the relay 

gets open 

(door closed). 

When the 

programming mode

 is activated, only this mode will be notified by 

lighting 

the LED in red

.  

Note

Securel  can  be  paired  or  open/close  the  relay  while  the  programming  mode  is 

active, but only the programming mode is notified (i.e., the LED remains lighting in red)

A  long  press

  (longer  than  three  seconds) 

will  always  activate  the  pairing  mode

regardless of if the programming mode is active or not (if it is active, is deactivated). 

In short, the different states that are notified are: 

    Programming mode: 

Red LED ON

    Pairing mode (Securel not paired): 

B

l

u

L

E

D

 b

l

i

n

k

i

n

g

    Relay Status (Securel paired): 

  Open (door closed): Green LED off. 

  Closed (door opened): 

Green LED on

 

 

Содержание Securel ZIO-SEC

Страница 1: ...Securel Access Controller Encrypted Relay ZIO SEC USER MANUAL ds kmfroi Application Program Version 1 1 User manual edition 1 1 _a www zennio com...

Страница 2: ...3 1 1 Securel 3 1 2 Access Control System 4 1 3 Installation 4 2 Pairing with IWAC 7 3 LED Notification 8 4 Securel status 9 4 1 Default status 9 4 2 Status after programming 9 4 3 Status after bus fa...

Страница 3: ...d it uses encrypted information to communicate with the access control device known as IWAC In this way the inviolability of the system is assured The most notable features of this device are Acting o...

Страница 4: ...pen command is correctly received from IWAC access granted Securel will release the lock for a while to open the door BMS Building Management System computer system that assumes the integral automatio...

Страница 5: ...onnectors 3 On the other hand Securel powers the electric strike also using one of the other positive supply terminals 1 and the terminal of the electric strike output as neutral 2 Moreover the relay...

Страница 6: ...trol system it is necessary to locate Securel inside the room of the management module establishing an encrypted communication with IWAC To get detailed information about the technical features of thi...

Страница 7: ...h any IWAC before it will be in pairing mode Only connect the Securel to the IWAC desired to pair with and they will be automatically paired If Securel is paired with an IWAC press the programming but...

Страница 8: ...door closed When the programming mode is activated only this mode will be notified by lighting the LED in red Note Securel can be paired or open close the relay while the programming mode is active bu...

Страница 9: ...any action on the lock until a first order is received from the IWAC If Securel was not paired remains in pairing mode 4 3 STATUS AFTER BUS FAILURE A KNX bus power failure does not imply any change in...

Страница 10: ...is General From this screen it is possible to configure all the required functionality Figure 5 General Configuration Opening Time time the lock remains open after receiving the opening command Range...

Страница 11: ...ter download or bus failure takes place with a delay of up to 255 seconds to prevent bus overload The following sendings match the period set Note Take into account that Securel must be paired with th...

Страница 12: ...other values permitted by the bus according to the object size may be of any use or have a particular meaning because of the specifications or restrictions from both the KNX standard or the applicatio...

Страница 13: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...

Отзывы: