background image

 

 

 

MAXinBOX 66

 

http://www.zennio.com

 

   

Technical Support:

 

http://zennioenglish.zendesk.com

 

 

15 

2.5

 

THERMOSTATS 

MAXinBOX  66  implements 

four  Zennio  thermostats

  which can be enabled and 

configured independently.  

Please refer to the specific “

Zennio  Thermostat  in  MAXinBOX 66

” user manual 

(available at the Zennio homepage, 

www.zennio.com

) for detailed information about 

the functionality and the configuration of the related parameters. 

 

 

 

 

Содержание MAXinBOX 66

Страница 1: ...MAXinBOX 66 Multifunction Actuator with 6 Outputs and 6 Inputs USER MANUAL ZN1IO MB66 Application program version 1 2 User manual edition 1 2 _a www zennio com...

Страница 2: ...oduction 4 1 1 MAXinBOX 66 4 1 2 Installation 5 1 3 Start Up and Power Loss 6 2 Configuration 7 2 1 General 7 ETS Parameterisation 7 2 2 Inputs 8 2 3 Outputs 10 2 3 1 Manual Control 10 ETS Parameteris...

Страница 3: ...zennio com Technical Support http zennioenglish zendesk com 3 DOCUMENT UPDATES Version Changes Page s 1 2 _a Changes in the application program Optimisation of the timed actions management in the log...

Страница 4: ...N OFF outputs A combination of the above 6 multi purpose inputs configurable as Temperature probes Binary inputs i e pushbuttons switches sensors Motion detectors 10 customisable multi operation logic...

Страница 5: ...ibed next Test Prog Pushbutton 8 a short press on this button sets the device into the programming mode making the associated LED 5 light in red Note if this button is held while plugging the device i...

Страница 6: ...at www zennio com 1 3 START UP AND POWER LOSS During the start up of the device the Test Prog LED will blink in blue colour for a few seconds before MAXinBOX 66 is ready External orders will not be ex...

Страница 7: ...ctivate all the required functionality Figure 2 General screen Once activated Inputs Outputs Logical Functions Thermostats and Master Light bring additional tabs to the menu on the left These function...

Страница 8: ...cific user manual Binary Inputs in MAXinBOX 66 2 2 2 TEMPERATURE PROBE Please refer to the specific user manual Temperature Probe in MAXinBOX 66 2 2 3 MOTION DETECTOR It is possible to connect motion...

Страница 9: ...lightly Therefore please refer specifically to the aforementioned user manual Zennio Motion Detector for MAXinBOX 66 Motion detectors with references ZN1IO DETEC and ZN1IO DETEC N are not compatible w...

Страница 10: ...f its output relays through the respective pushbuttons on the top of the device A specific pushbutton is therefore available per output Manual operation can be done in two different ways named as Test...

Страница 11: ...t or long will make the output switch its on off state which will be reported to the KNX bus through the corresponding status object if enabled Shutter Channel when the button is pressed the device wi...

Страница 12: ...e move upward or downward depending on the button until the button is released again thus ignoring the position of the shutter and the parameterised times Note after leaving the Test On mode the statu...

Страница 13: ...ction while switching to the Test On mode does require long pressing the Prog Test button Lock Manual Control unless the above parameter has been Disabled the Lock Manual Control parameter provides an...

Страница 14: ...he execution of each function can depend on a configurable condition which will be evaluated every time the function is triggered through specific parameterisable communication objects The result afte...

Страница 15: ...66 implements four Zennio thermostats which can be enabled and configured independently Please refer to the specific Zennio Thermostat in MAXinBOX 66 user manual available at the Zennio homepage www...

Страница 16: ...he KNX bus in both cases a shutter order a thermostat setpoint or mode switch order a constant value a scene Only the trigger object and the twelve status objects are required to be binary on off The...

Страница 17: ...ct ML General Switch off Scene will be enabled which will send a scene run save order configurable in Action and Scene Number whenever the general switch off takes off HVAC if checked object ML Genera...

Страница 18: ...OX 66 http www zennio com Technical Support http zennioenglish zendesk com 18 General Switch Off Binary Object which sends the value 0 during the general switch off as explained above Figure 4 Master...

Страница 19: ...7 97 2 Bytes S C T R DPT_Value_Temp 273 00 670760 00 Tx Effective Temperature Effective Control Temperature 8 38 68 98 1 Byte E C W DPT_HVACMode 1 Comfort 2 Standby 3 Economy 4 Building Protection Tx...

Страница 20: ...riable Heat PI Control Continuous 29 59 89 119 1 Bit S C T R DPT_Switch 0 1 Tx Control Variable Cool 2 Point Control 1 Bit S C T R DPT_Switch 0 1 Tx Control Variable Cool PI Control PWM 30 60 90 120 1...

Страница 21: ...80 1 Bit E C W DPT_Trigger 0 1 Ix Presence Slave Input 0 Nothing 1 Detection from slave device 159 183 207 231 255 281 1 Bit E C W DPT_Trigger 0 1 Ix External Motion Detection 0 Nothing 1 Motion detec...

Страница 22: ...rm 0 Unfreeze 1 End Alarm 306 321 336 1 Bit E C W DPT_UpDown 0 1 C Move Reversed 0 Lower Shutter 1 Raise Shutter 307 322 337 1 Bit E C W DPT_Trigger 0 1 C Direct Positioning 0 No Action 1 Go to Positi...

Страница 23: ...1 Bit C T DPT_Step 0 1 Ix Short Press Stop Step Up Shutter Sending of 0 Stop Step up 1 Bit C T DPT_Step 0 1 Ix Short Press Stop Step Down Shutter Sending of 1 Stop Step down 1 Bit C T DPT_Step 0 1 Ix...

Страница 24: ...Press 0 Sending of 0 1 Bit C T DPT_Switch 0 1 Ix Long Press 1 Sending of 1 1 Bit E C T W DPT_Switch 0 1 Ix Long Press 0 1 Switching Switching 0 1 1 Bit C T DPT_UpDown 0 1 Ix Long Press Move Up Shutte...

Страница 25: ...ng Status input 0 100 1 Byte E C W DPT_Scaling 0 100 Ix Long Press Shutter Status input 0 Top 100 Bottom 426 1 Bit E C W DPT_Trigger 0 1 ML Trigger Trigger the Master Light Function 427 1 Bit E C W DP...

Страница 26: ...LF 1 byte Data Entry x 1 byte Data Entry 0 255 495 510 2 Bytes E C W DPT_Value_2_Ucount 0 65535 LF 2 bytes Data Entry x 2 bytes Data Entry DPT_Value_2_Count 32768 32767 DPT_Value_Temp 273 00 670760 00...

Страница 27: ...your inquiries about Zennio devices http zennioenglish zendesk com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 Fax 34 925 337 310 www zennio com...

Отзывы: