background image

   

 

 

 

 

 

 

 

 

 

 

 

INZennio

 

Z38i

 

 

INZennio

 

Z38i

 

 

Touch

 

Display

 

with

 

Ambient

 

Thermostat,

 

IR

 

receiver

 

and

 

Binary

 

Inputs.

 

ZN1VI

TP38i

          

 

 

 

 

 

                                             

Technical

 

Documentation

 

 

© Zennio Avance y Tecnología S.L.                        Edition 1                             Further information 

www.zennio.com

                        

Page 

1

 de 

Technical

 

Documentation

 

CHARACTERISTICS: 

 

ƒ

 

KNX 3.8” back-lighted monochrome Touch Panel 

ƒ

 

Room Thermostat 

ƒ

 

12 configurable direct control functions  

ƒ

 

6 additional screens with up to 6 functions each: 

o

 Scenes 

o

 Alarms 

o

 Schedule 

programming 

o

 Climate 

Management 

o

 Display 

parameters 

ƒ

 

IR receiver 

ƒ

 

4 binary inputs for potential free push buttons  

ƒ

 

Only bus connection is required 

ƒ

 

No Power Supply different from the BUS required 

ƒ

 

KNX BCU included 

ƒ

 

Complete Data Saving in case of Power Failure 

ƒ

 

CE directives OK 

 

CONCEPT DESCRIPTION 

o

  Device Type 

Electric Operation Control Device 

o

 EIB/KNX 

Supply 

o

  Voltage 

29V DC SELV 

o

  Voltage range 

20...31V DC 

o

  Consumption 

480mW (two pay loads) 

o

  Connection Type 

Typical BUS connector TP1, 0,50 mm² section 

o

  External Power Supply 

No 

o

  Operating Temperature 

0º C to +45º C 

o

  Storage Temperature 

-20º C to +60º C 

o

  Ambient humidity (relative) 

30 to 85% RH (no condensation) 

o

  Storage humidity (relative) 

30 to 85% RH (no  condensation) 

o

  Complementary characteristics 

Class B 

o

 Safety 

class 

II 

o

  Operation type 

Continuous operation 

o

  Device action type 

Type 1 

o

  Electrical solicitations period 

Long 

o

  Nº of Automatic cycles per auto action 

100.000 

o

  Type of Protection  

IP20. Clean environment 

o

 Assembly 

Independent Control Assembly device 
Vertical position, with the IR receiver and the 
temperature sensor to the bottom. See “installation 
figure” 

o

 Minimum 

clearances 

Keep away from heat and cold air flows to get better 
temperature sensor measures 

o

  Response to BUS voltage failure 

Complete data saving 

o

  Response to BUS failure recovery 

Before Failure Data recovery  

o

  Function indicator 

Several on Display as programmed  

o

 Accessories 

IR 

Remote Control (optional) 

o

  PCB CTi index 

175 V 

o

 Enclosure 

PC-ABS, 

flammability category class D 

o

 Weight 

250 

gr. 