2.2

 

MOTION DETECTOR 

EyeZen  TP  v2  incorporates  six  independent  motion  detection  channels,  two  more  for 

constant light control and one for occupancy detection.  

 

Motion detection

 consists in sending objects to the bus whenever the device 

observes a moving body (or no longer observes it) in the environment of the 

room where it has been installed. 

 

Constant light control

 consists in sending KNX orders to the dimmer device 

that controls the in-room luminaries so the ambient light level remains constant 

even if other light sources are present. 

 

Occupancy  detection 

is  an  algorithm  that  allows  determining  whether  a 

particular  space is under occupation no matter if the occupant moves or not 

(i.e., no matter if the device is detecting motion in the room or not). 

It also allows setting different luminosity setpoints or object types for 

daytime

 

and night 

time 

as well as activating or deactivating the

 motion indicator LEDs

EyeZen TP v2 can also set custom 

sensitivity

 of the motion sensor and measure the 

luminosity

 of the room by making certain adjustments. This measurement will be made 

according to the 

color of lens

 selected. 

Please  refer  to  the  specific  manual  “

Presence  Detector

”  available  in  EyeZen  TP  v2 

product section at the Zennio website (

www.zennio.com

) for detailed information about 

the  functionality  and  the  configuration  of  the  related  parameters.  Please  note  that 

references  to  presence  detection  in  this  manual  in  this  case  correspond  to  motion 

detection. 

 

 

Содержание EyeZen TP v2

Страница 1: ...EyeZen TP v2 Motion detector with luminosity sensor for ceiling mounting ZPDEZTPV2 USER MANUAL Application program version 1 5 User manual edition 1 5 _a www zennio com...

Страница 2: ...pport https support zennio com 2 CONTENTS Contents 2 1 Introduction 3 1 1 EyeZen TP v2 3 1 2 Installation 4 1 3 Start Up and Power Loss 5 2 Configuration 6 2 1 General 6 2 2 Motion Detector 8 2 3 Logi...

Страница 3: ...figurable sensitivity LED to indicate motion Two colours of lenses white and black Motion detection 6 motion detection channels Luminosity dependent motion detection optional Periodic and delayed send...

Страница 4: ...owered through the KNX bus Figure 1 EyeZen TP v2 Elements The main elements of the device are described next Programming button 3 a short press on this button sets the device into the programming mode...

Страница 5: ...Datasheet bundled with the original packaging of the device and also available at www zennio com 1 3 START UP AND POWER LOSS During the start up of the device the detection notification LED flashes r...

Страница 6: ...ur that EyeZen TP v2 has installed for correct sensor luminosity measurement Motion Detection enabled enables the Motion Detector tab in the tree on the left For more information see section 2 2 Logic...

Страница 7: ...1 enabled disabled this parameter lets the integrator activate two new communication objects Heartbeat Device Recovery which will be sent to the KNX bus with values 0 and 1 whenever the device begins...

Страница 8: ...rmining whether a particular space is under occupation no matter if the occupant moves or not i e no matter if the device is detecting motion in the room or not It also allows setting different lumino...

Страница 9: ...ion of each function can depend on a configurable condition which will be evaluated every time the function is triggered through specific parameterisable communication objects The result after executi...

Страница 10: ...12 1 Bit I C W DPT_DayNight 0 1 Day Night 0 Day 1 Night 1 Bit I C W DPT_DayNight 0 1 Day Night 0 Night 1 Day 13 1 Bit I C W DPT_Enable 0 1 Detection LED 0 Disable 1 Enable 1 Bit I C W DPT_Enable 0 1 D...

Страница 11: ...ock 1 Lock 1 Bit I C W DPT_Enable 0 1 CLCx Lock Status 0 Lock 1 Unlock 83 99 1 Bit I C W DPT_Start 0 1 CLCx Force State 0 No Detection 1 Detection 84 100 1 Bit I C W DPT_Start 0 1 CLCx External Switch...

Страница 12: ...255 LF 1 Byte Data Entry x 1 Byte Data Entry 0 255 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 2 Bytes I C W DPT_Value_2_Ucount 0 65535 LF 2 Byte Data Entry x 2 Byte Data Entry 17...

Страница 13: ...n and send us your inquiries about Zennio devices https support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio...

Отзывы: