32
Symbol
Status
Measure
External voltage
-
Flow existent
-
Attention!
Check system /device
for errors
■
SSymbol flashing: Data transmission
■
Symbol constantly displayer: optical
interface active
-
-
Emergency operation
Exchange device
Error codes show faults detected by zelsius
®
C5-IUF. If more than one
error appears, the sum of the error codes is displayed: Error 1005 = error
1000 and error 5.
Code
Error
Measure
1
Temperature out of measuring range Check sensors
2
Temperature out of measuring range Check sensors
3
Short circuit return sensor
Check sensors
4
Interruption return sensor
Check sensors
5
Short circuit supply sensor
Check sensors
6
Interruption supply sensor
Check sensors
7
Battery voltage
Exchange device
8
Hardware error
Exchange device
9
Hardware error
Exchange device
10
Error in the measuring system
Exchange device (**)
20
No water in the measuring tube
Check operating pressure (**)
30
Reverse water flow detected
Check installation position (**)
40
Air inside the medium
Vent system (**)
50
Measured value outside overload
range
Check dimensioning (**)
100
Hardware error
Exchange device
800
Wireless interface
Exchange device
1000
Status end of the battery
Exchange device respectively
battery
2000
Status Initial verification expired
Exchange device
(**) only by zelsius
®
C5-IUF
Status display / Error codes
The symbols in the table below show the meter’s operational status. The
status messages only appear in the main display (energy)! The temporary
display of the warning triangle can be caused by special operating states
and does not always mean that the device is malfunctioning. However,
should the symbol be displayed over a longer period of time, you should
contact the service company.