Status display / Error codes

The symbols in the table below show the pulse counting module’s operational status. The status 
messages only appear in the main display! The temporary display of the warning triangle can be caused 
by special operating states and does not always mean that the device is malfunctioning. However, 
should the symbol be displayed over a longer period of time you should contact the service company.

Error codes show faults detected by  multipulse resp. multilog. If more than one error appears, the sum of 
the error codes is displayed: Error 1100 = error 1000 and error 100.

Symbol Status 

Event

 

Flow existent 

-

 

Data transmission 

-

 

Emergency operation 

Exchange device

 

External power supply 

-

Code Error 

Event

100 

Emergency operation 

Exchange device

1000 

Battery life time exceeded 

Exchange device

> 8000 

Internal hardware error 

Exchange device

ZE12B28_MA_Multipulse_EN_V2_D   10

10.10.12   17:24

Содержание multilog

Страница 1: ...multilog Installation and operating manual Electronic pulse counter module with 3 inputs for connection of meters with pulse outputs EnergyMetering All that counts ZE12B28_MA_Multipulse_EN_V2_D 1 10 1...

Страница 2: ...onal requirements for interference resis tance To avoid malfunctions due to other inter ferences do not install fluorescent lamps switch cabinets or electric devices such as motors or pumps in the imm...

Страница 3: ...max 1Hz active max 100 Hz Interfaces optical optionally ZR Bus M Bus RS 232 Ambient temperature C 0 55 Power supply Battery 3 6 V Lithium optionally mains supply 230 V Battery lifetime 6 years optiona...

Страница 4: ...ty factor 1 1 to 1 9 Input capacitance approx 15 nF Input resistance approx 470 kOhm 1 Hz Version fmax 1 Hz Pulse duty factor 1 1 to 1 9 Input capacitance approx 10 nF Input resistance approx 850 kOhm...

Страница 5: ...information in our product area at www zenner com 1 2 3 4 10 11 9 50 51 52 53 54 55 24 25 24 25 Version M Bus 1 2 3 4 10 11 9 50 51 52 53 54 55 Version without interface 1 2 3 4 10 11 9 50 51 52 53 54...

Страница 6: ...ithin one years time M Bus optional The optional M Bus interface complies with the norm EN 1434 3 and operates with 2400 baud fixed It can be set to 300 9600 baud if necessary B H T Subject to modific...

Страница 7: ...are of the display of the module must readable at all times to avoid malfunctions due to other interfer ences do not install fluorescent lamps switch cabinets or electric devices such as motors or pum...

Страница 8: ...r a little bit place the module on the rail and push the adapter back until it locks Connection meter With mechanical meters the connection order is optional Mind the polarity at electronic meters Ext...

Страница 9: ...next measuring cycle and displayed again When attaching the top cover on the housing pulses on the inputs can possibly be generated Check readings of the inputs and correct if nec essary Sealing We r...

Страница 10: ...yed over a longer period of time you should contact the service company Error codes show faults detected by multipulse resp multilog If more than one error appears the sum of the error codes is displa...

Страница 11: ...input Monthly value main Date month input 1 Date month input 2 Monthly value inpu Monthly value inpu Monthly values input 1 Monthly values input 2 Serial number Customer number Serial number input 1...

Страница 12: ...down the button H until the device switches to another level or switches back from the sub menu Note Depending on your mulipulse or multilog model its displays can differ in number and order from thos...

Отзывы: