Tudor - Installation & Operating Instructions - 85807 - June 2012 v1.00
Page 7
This appliance may only be serviced by a suitably qualified technician.
Disconnect from power and turn water supply OFF before attempting any kind
of service work.
Removing the case
1. Remove temperature control knob by gripping it and pulling towards you.
2. Remove the single retaining screw located beneath the temperature control knob.
3. Remove the four case screws two at top, two at bottom.
4. The case can now be lifted off carefully.
Replacing the case
Reverse of the above procedure.
Replacing a thermostat
1. Remove the front cover.
2. Disconnect the two electrical terminals from the thermostat. These are
spade connectors and can be easily pulled off.
3. Remove the two screws attaching the thermostat to the plastic upright.
4. Pull the capillary out of the thermostat pocket located on the element
assembly.
5. Take the new thermostat (90421NZ) and uncoil about half of the capillary
tube.
6. Push the new capillary into the pocket ensuring that:
a) if it is an over sink model, the cutout bulb goes in first then the
thermostat bulb behind it.
b) if it is a under sink model, then the reverse is applicable.
Attach the thermostat to the plastic upright.
Reconnect the two electrical terminals. It does not matter which way around
the connections occur.
Ensure the remaining capillary coil is out of the way of any live terminals.
Ensure the plastic upright is located securely in the position provided.
Refit the cover assembly.
# Service
Procedures
Knob removed to show screw
Thermostat spade connectors
End of life disposal
In order to help preserve our environment we ask that you dispose of this product correctly. Please contact your
local city council for collection centre details.