background image

 Tudor - Installation & Operating Instructions - 85807 - June 2012 v1.00 

 

Page 7

This appliance may only be serviced by a suitably qualified technician.
Disconnect from power and turn water supply OFF before attempting any kind 
of service work.

Removing the case

1. Remove temperature control knob by gripping it and pulling towards you.
2. Remove the single retaining screw located beneath the temperature control knob.
3. Remove the four case screws two at top, two at bottom.
4. The case can now be lifted  off carefully.

Replacing the case

Reverse of the above procedure.

Replacing a thermostat

1. Remove the front cover.
2. Disconnect the two electrical terminals from the thermostat. These are 
spade connectors and can be easily pulled off.
3. Remove the two screws attaching the thermostat to the plastic upright.
4. Pull the capillary out of the thermostat pocket located on the element 
assembly. 
5. Take the new thermostat (90421NZ) and uncoil about half of the capillary 
tube.
6. Push the new capillary into the pocket ensuring that:

 

a) if it is an over sink model, the cutout bulb goes in first then the  

 

 

thermostat bulb behind it.

 

b) if it is a under sink model, then the reverse is applicable.

Attach the thermostat to the plastic upright.

Reconnect the two electrical terminals. It does not matter which way around 
the connections occur.

Ensure the remaining capillary coil is out of the way of any live terminals.

Ensure the plastic upright is located securely in the position provided.

Refit the cover assembly.

# Service 

Procedures

Knob removed to show screw

Thermostat spade connectors

End of life disposal

In order to help preserve our environment we ask that you dispose of this product correctly. Please contact your 
local city council for collection centre details.

Содержание Tudor series

Страница 1: ...k water heater 21101NZ Tudor 10 Litre over sink water heater 21102NZ Tudor 10 Litre under sink water heater 99006NZ Telescopic swivel arm only 99032NZ Telescopic Spout accessory for 21051NZ 21052NZ 99...

Страница 2: ...eater The heater is unsuited for use by children or infirm people without supervision If the power supply cord is damaged it must be replaced by a Service Provider or a qualified electrician Do not re...

Страница 3: ...th a WHITE band on it connects to the tap hole with NO marking 5 The hose with a RED band on it connects to the tap hole with a RED marking 6 The hose with a BLUE band on it connects to the tap hole w...

Страница 4: ...must be accessible Do not turn the power ON until the heater is filled with water and air is purged from the heater Step Five Commissioning Fill the heater tank and purge air from the heater by turni...

Страница 5: ...tall approved vented tapware see page 3 Tudor Heater Restrictaflow see page 4 265 5L 355 10L I I I I I I I E Tudor udor DEPTH 215 5L 265 10L WIDTH 255 5L 310 10L HEIGHT 390 5L 455 10L SIDE VIEW 100 14...

Страница 6: ...r temperature could fall below 5 C when the heater is not in use the anti freeze setting on the temperature control will maintain stored water temperature over 5 C to prevent freezing and damage to th...

Страница 7: ...t to the plastic upright 4 Pull the capillary out of the thermostat pocket located on the element assembly 5 Take the new thermostat 90421NZ and uncoil about half of the capillary tube 6 Push the new...

Страница 8: ...establish date of installation should it become necessary to service the appliance under terms of the Zenith warranty To register your installation go to www zenithheaters co nz and look under the hea...

Отзывы: