background image

802700NZ - Commercial Installation Instructions - Aug 2015 -  V2.01 

Page 29 of 32

Section 7

Commissioning

7.1

 - 

CO2 Purge (CS175 Model)

1. 

Press the [START] button to commence the purging 
process. 

2. 

Purge for 10 seconds and ensure all water has stopped 
flowing through the tap. (You will hear the CO2 gas 
escaping from the tap).

3. 

Press the [Stop] button.

4. 

Press [Next] for the filter flush screen

The Celsius is now ready to be commissioned. 

• 

Turn ON the water and check for any leaks.

• 

Turn the power ON at the GPO and at the side of the undersink unit

• 

If fitted, ensure the Booster is turned OFF. (The Booster is commissioned, later, at section 7.4)

• 

Familiarise yourself with the operation of the Tap, in preparation for use (See User Guide)

• 

Follow the Installation instructions below (and review Section C of the User Guide). 

• 

Initially you will be prompted to select a language

• 

After commissioning, the system may be customised by selecting further options in                     
Section G - Settings, within the User Guide.

Have a 10L bucket or similar container (not supplied) at the 
ready to hold a quantity of water that will be ejected while the 
Filter Flush Mode is in operation. Open the filter access door 
on the front of the HydroTap and the filter cartridge will be 
exposed. Located to the rear RHS of the cartridge is a flush 
line, approx 600mm long and the flush line stop cock. Place 
the valve end of the flush line into the 10L bucket or container.    

OPEN 

CLOSED 

Stop cock
operation

7.2

Filter Flush (All)

1. 

Press [Start] [Stop] buttons to start and stop the filter 
flush.

2. 

Turn the flush line stop cock ON  (See diagram).

3. 

Press [Start] and allow at least 10 litres of water to flush 
through the filter.

4. 

The product details will be displayed in the screen.

5. 

Once the filter flush is finished, Turn the stop cock OFF 
then press [Stop] to end filter flush mode. 

Содержание HydroTap G4 Celsius Series

Страница 1: ...5 V2 01 Page 1 of 32 HydroTap G4 Celsius Installation Instructions Filtered Boiling Chilled and Chilled Sparkling drinking water with unfiltered Hot and Cold ambient water for commercial kitchens Affi...

Страница 2: ...Page 2 of 32 802700NZ Commercial Installation Instructions Aug 2015 V2 01 Models Model B160 B240 Model C125 C175 Model CS175...

Страница 3: ...ocedures 15 16 STEP 3 Install the Booster heater B240 Model Section 3 Booster 17 3 1 Specification 18 3 2 Installation and Removal 19 STEP 4 Filter Softener If required Section 4 Filter Installation 2...

Страница 4: ...orrect power is available for the appliance F Check the under counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Chec...

Страница 5: ...g tap mounted on a kitchen sink or bench These units utilise a conventional refrigerant compressor to chill the water and a CO2 gas cylinder to carbonate the chilled water The Celsius taps will dispen...

Страница 6: ...y qualified tradesperson The power cable and power outlet must be in a safe visible position for connection Venting Sometimes steam and or condensed droplets may discharge through a vent outlet at the...

Страница 7: ...rding to MSDS Material Safety Data Sheet WARNINGS 1 The Zenith Celsius unit must be earthed The resistance of the earth connection from each exposed metal part must be less than 1 ohm 2 All Installati...

Страница 8: ...with hoses 1 off Undersink Unit with air and water filters 1 off Mains water connection hose Vent Kit 1 x Inlet vent 1 x Outlet vent 9 x Screws 1 x Tee piece for ambient water supply 1 x User guide an...

Страница 9: ...the Installation site Review all the technical specifications Ensure the underbench can support the product weight when full of water Sufficient space in the cupboard to install all of the undersink...

Страница 10: ...iameter sheet metal hole punch for sink tops Not supplied 35mm diameter hole saw for timber bench tops Not supplied 42mm AF tube spanner or wrench Not supplied for fixing tap assembly Section 1 Tap In...

Страница 11: ...e in the bench sink top BENCH TOP 1 1 35mm HOT COLD BRAIDED HOSES CHILLED TUBE BRASS WASHER BLACK RUBBER Seal BRASS NUT USB PLUG SPARKLING TUBE JG Y PIECE Note Trim all plastic tubes to minimise any d...

Страница 12: ...Installation Instructions Aug 2015 V2 01 HOT COLD BRAIDED HOSES BOILING or CHILLED TUBE BRASS WASHER BLACK RUBBER SEAL BRASS NUT VENT TUBE USB PLUG 1 3 B160 B240 and C125 C175 Tap connections RUBBER...

Страница 13: ...hole Ensure the black rubber seal is correctly positioned to give a water tight seal FIT THE RUBBER WASHER BRASS WASHER AND LARGE NUT BLACK RUBBER SEAL 35mm HOLE IN BENCH TOP 1 4 Secure the rubber br...

Страница 14: ...s for a 50mm air gap either side and 300mm above of the undersink unit It is important that the 4mm door buffers For all installations are fitted to the inside edge of the cupboard door to allow sufic...

Страница 15: ...B C 2 2 Standard ventilation for Chilled and Chilled Sparkling models A Kickboard cutout 1 Drill 4 pilot holes 12mm dia in corners 2 Finish cutout using a Jigsaw and Kethole or Wall board saw B Cabin...

Страница 16: ...Drill four pilot holes 12mm dia 2 3 When standard ventilation cannot be used the following instructions are critical if there is insufficient cupboard air circulation Cutout details For low use appli...

Страница 17: ...ed to provide pre heating of water before it enters the Zenith HydroTap G4 boiling tank The Booster is supplied as standard equipment with all 240 cup models However it may be later installed as an ac...

Страница 18: ...ctions on top of the Booster The hot water outlet hose must be thermally insulated with the insulation provided Tilt Forward Lift UP Release Note Remove the backing plate for wall mounting 3 3 To Remo...

Страница 19: ...fitting on the Zenith HydroTap to the water inlet of the booster unit Marked Blue and from the outlet of the booster unit Marked Red to the Bypass IN fitting on the Zenith HydroTap unit Avoid exertin...

Страница 20: ...ouching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 3 Moisten the O rings with water align the front cartridge label to the left and push the new c...

Страница 21: ...asy fit over the spigot soak it in hot water before re applying Do not force the seal to fit Turn the regulator OFF by rotating the regulator knob all the way out in an anti clockwise direction NOTE T...

Страница 22: ...ect the joint for leaks 4 If any bubbles appear the joint will need to be resealed CO2 Regulator 5 5 Leak Test This gauge shows the pressure in the bottle and indicates when the bottle is empty Initia...

Страница 23: ...cut at an angle 2 Remove any swarf or unwanted material 3 Push the tube into the John Guest fitting making sure all connections to the John Guest fittings are pushed in past the O ring to full depth...

Страница 24: ...feed water bypass the internal filter and only be filtered by the external filtration This diverter valve is located at the rear panel of the undersink unit on the filter door side see the image below...

Страница 25: ...required for B160 HydroTap POWER CORD USB MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT RED CLEAR BRAIDED Max 1400mm Max 450mm 280mm Note All silicon tubes must be cut to size The...

Страница 26: ...OWER CORD USB MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT RED CLEAR BRAIDED Booster Not required for B240 HydroTap Booster option Note All silicon tubes must be cut to size They...

Страница 27: ...HILLED OUTLET MAINS IN 336mm MAX 1490 mm MAX 400 mm Min 35 mm 6 6 Model C125 Model C175 BLUE BRAIDED Installation Instructions Note All silicon tubes must be cut to size They must have a constant fall...

Страница 28: ...lengths are matched to the pumps performance and therefore CANNOT be lengthened Take time to consider hose lengths when determining the mounting positions for the options Note All silicon tubes must b...

Страница 29: ...ally you will be prompted to select a language After commissioning the system may be customised by selecting further options in Section G Settings within the User Guide Have a 10L bucket or similar co...

Страница 30: ...ton 4 In the next screen press YES to enable the Booster 5 Turn the Booster ON 6 Water must be run through the Booster for a min of 30 seconds before the heater will activate 7 Dispense boiling water...

Страница 31: ...Internal fault Call Zenith Service Condenser sensor Closed Internal fault Check Ventilation Call Zenith Service Condenser sensor Open Internal fault Check ventilation Call Zenith service Heater fuse...

Страница 32: ...825 and SA2006 08043 Other patents are in force and patent applications are pending As Zenith policy is one of continuous product improvement changes to specifications may be made without prior notice...

Отзывы: